DataSheet26.com

WH7016C PDF даташит

Спецификация WH7016C изготовлена ​​​​«Willhi Electronics» и имеет функцию, называемую «Thermostat Manual».

Детали детали

Номер произв WH7016C
Описание Thermostat Manual
Производители Willhi Electronics
логотип Willhi Electronics логотип 

5 Pages
scroll

No Preview Available !

WH7016C Даташит, Описание, Даташиты
WH7016C
Thermostat Product
Manual
Shenzhen Willhi Electronics Co., Ltd.
Tel :0755 -29539385 Fax :86-0755 -2953 9395
Technical support: Engineer Tian









No Preview Available !

WH7016C Даташит, Описание, Даташиты
Installation opening size:
Wiring diagram
Option
switch
Load
Terminals 1 and 2: Normally opened contact of relay
Terminals 3 and 4: Connect the power 12V
Terminals 5 and 6: The factory parameter settings of thermostat can be
locked after a short circuit, the user can not modify.
Terminals 7 and 8: Temperature connection sensor
Note: The load refers to the heating or cooling equipment on control.
Electrical performance:
Temperature measurement range: -50 ~ 110
Temperature control range: -50 ~ 110
Temperature measurement error: ± 0.5
Sensor Type: NTC (10K/3435)
Control accuracy: 1
Working voltage: AC/DC12V
Working current: <2W
Relay contact point current: AC 7A/220V
Data storage : Yes
Working temperature: 0 ~ 50
Storage temperature: -10 ~ 60









No Preview Available !

WH7016C Даташит, Описание, Даташиты
Key Instructions:
1. RST: Press RST key to switch on and off, press the RST key on the
power-off state once to turn on, on the power-on state, press the RST key
for three seconds and hold on, then it will be off.
2. SET:
A: Press the SET key once to enter the temperature control setting, press
or button to adjust, press or button for three seconds and hold
to enter the fast adjusting mode, press the SET key again to exit setting
mode.
B: Press and hold SET key for three seconds to enter the system menu
settings, press the or key to select the adjustment menu, press SET
key once to enter the appropriate parameter settings, press or to
adjust the parameters needed to be modified, after being adjusted, press
the RST key to exit, or exit as the system delay for 5 seconds.
: Up key
: Down key
Operating Instructions:
LED Status Description:
The WORK lights at the left side of the screen is used as working indicator
lights, flashing is to indicate the delay of cooling or heating, if the LED is
always on ,it indicates it is on the status of cooling or heating .
The SET light at the left side of the screen lights is used as setting indicator
lights, if the LED is always on ,it indicates it is on the status of setting.
.
Function Instructions:
Press RST key to open the thermostat, on the running status, press this key
for 3 seconds, then the thermostat can be turned off.
Cooling, heating function:
Cooling Mode: When the measured temperature is higher than or equal to
the set value + hysteresis, the relay picks up to start the output; When the
measured temperature below the set value, the relay off and close the output.
Heating mode: When the measured temperature is higher than or equal to
the set value, the relay off, turn off the output; When the measured
temperature below the set value - hysteresis, the relay picks up to start the
output.
Example for Setting: If it is set to heating mode, set the temperature to 25
degrees, hysteresis is set to 5, then when the measured temperature is
higher than or equal to 25 degrees, the relay is off, close the output.
When the temperature is below 20 degrees, pick up the relay again, to
start the output.
Example for Setting: If it is set to cooling mode, set the temperature to 25
degrees, hysteresis is set to 5, then when the measured temperature is
below 25 degrees, the relay is off, close the output. When the
temperature is higher than or equal to 30 degrees, pick up the relay again,
to start the output.
Cooling, heating mode setting:
Press "SET" key and hold more than 3 seconds to enter the menu display, the
screen appears "HC" code, press the "SET" key to display the working mode,
press the "" or "" to adjust the display, C means cooling mode; H means
heating mode.
Hysteresis function:
Hysteresis setting limits the maximum interval between the opening and
stopping, this machine minimum interval between the opening and stopping is










Скачать PDF:

[ WH7016C.PDF Даташит ]

Номер в каталогеОписаниеПроизводители
WH7016CThermostat ManualWillhi Electronics
Willhi Electronics

Номер в каталоге Описание Производители
TL431

100 мА, регулируемый прецизионный шунтирующий регулятор

Unisonic Technologies
Unisonic Technologies
IRF840

8 А, 500 В, N-канальный МОП-транзистор

Vishay
Vishay
LM317

Линейный стабилизатор напряжения, 1,5 А

STMicroelectronics
STMicroelectronics

DataSheet26.com    |    2020    |