DataSheet26.com

NET1-4112 PDF даташит

Спецификация NET1-4112 изготовлена ​​​​«Power-One» и имеет функцию, называемую «Currents Over 100 Amps».

Детали детали

Номер произв NET1-4112
Описание Currents Over 100 Amps
Производители Power-One
логотип Power-One логотип 

3 Pages
scroll

No Preview Available !

NET1-4112 Даташит, Описание, Даташиты
NET1 SERIES
AdvaRnceeledasPeroduct
Designed to meet the stringent requirements of today’s high-speed
datacom and telecom circuitry, Power-One’s NET1 series is an excellent
compact power solution for low-voltage, high-current applications. The
NET1’s high efficiency is achieved through the use of synchronous
rectification and a newly-patented “Soft Transition Forward Converter”.
The NET1’s rectification method lowers output losses, reduces system
cooling requirements (allowing greater power in a smaller package), and
eliminates minimum load requirements.
Advanced surface-mount design and packing technology reduce the
NET1’s height to 1.35” (34.3mm) to fit in 1U applications. NET1’s
high-performance active power factor circuitry meets EN61000-3-2
requirements for compliance with European Power Line Harmonic
Requirements for 2001. A multifunctional output terminal allows
connection to #8 ring lugs, 0.25” quick disconnects, cable connectors,
and PCB-mounted connectors.
FEATURES
• Currents Over 100 Amps
• Fits 1U Chassis Height Constraints
• No Minimum Load Requirement
• Current Share Capabilities on All Outputs
• Patented High-Efficiency Design
• Meets European Power Factor Requirements for 2001
• Excellent Load Transient Response
MULTIPLE OUTPUT MODEL SELECTION CHART – 240W WITH 300 LFM FORCED AIR COOLING
MODEL
NET1-4325
NET1-4130
OUTPUT
VOLTAGE
+3.3V
+2.5V
+5V
+12V
+1.8V
+3.3V
+5V
+12V
ADJUSTMENT
RANGE
+0.5V
+0.5V
FIXED
FIXED
+0.5V
+0.5V
FIXED
FIXED
OUTPUT
CURRENT (NOTE 1)
50A
50A
5A
4A
50A
50A
5A
4A
LINE
REGULATION
0.2%
0.2%
0.2%
0.2%
0.2%
0.2%
0.2%
0.2%
LOAD
REGULATION
1%
1%
3%
3%
1%
1%
3%
3%
NET1-4112
+1.8V
+1.65V
+5V
+12V
+0.5V
+0.5V
FIXED
FIXED
50A
0.2%
1%
50A
0.2%
1%
5A
0.2%
3%
4A
0.2%
3%
NOTES: 1) Output currents ratings are expressed with 300 LFM forced air.
2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
RIPPLE & NOISE
%Pk-Pk (NOTE 2)
1% or 50mV
1% or 50mV
1% or 50mV
1% or 50mV
1% or 50mV
1% or 50mV
1% or 50mV
1% or 50mV
1% or 50mV
1% or 50mV
1% or 50mV
1% or 50mV
INITIAL SETTING
ACCURACY
± 30mV
± 30mV
± 30mV
± 100mV
± 20mV
± 30mV
± 30mV
± 100mV
± 20mV
± 30mV
± 30mV
± 100mV
INPUT SPECIFICATIONS
PARAMETER
Input Voltage - AC
Input Frequency
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
Power Factor
CONDITIONS/DESCRIPTION
Continuous input range.
AC input.
After last AC line peak at 240 watts.
85 VAC at full rated load.
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 220 VAC, one cycle, 25°C.
Per EN61000-3-2.
MIN TYP MAX UNITS
85 264 VAC
47 63 Hz
20 mS
4.0 ARMS
35 APK
0.95 W/VA
Rev. 11/2000
1









No Preview Available !

NET1-4112 Даташит, Описание, Даташиты
NET1 SERIES
OUTPUT SPECIFICATIONS
PARAMETER
Efficiency
Ripple and Noise
Output Power
Overshoot / Undershoot
Regulation
Transient Response
Turn-on Delay
Turn-on Rise Time
CONDITIONS/DESCRIPTION
Full Rated Load, 110 VAC. Varies with distribution of loads among outputs.
Full load, 20 MHz bandwidth.
With 300 LFM forced air cooling. (Note 1)
Output voltage overshoot/undershoot at turn-on.
Varies by output. Total regulation includes: line changes over the specified.
input range, changes in load starting at 20% load and changing to 100% load.
Recovery time, to within 1% of initial set point due to a 10-100% load change,
1% max. deviation.
Time required for initial output voltage stabilization.
Time required for output voltage to rise from 10% to 90%.
AdvaRnceeledasPeroduct
MIN TYP MAX
80
See Model Selection Charts
240
0
See Model Selection Charts
UNITS
%
Watts
%
500 µS
2 Sec
20 mS
INTERFACE SIGNALS AND INTERNAL PROTECTION
PARAMETER
Overvoltage Protection
Overload Protection
Overtemperature Protection
Output Good
Input Power Fail Warning
Current Share
Remote Sense
CONDITIONS/DESCRIPTION
MIN TYP MAX
Overvoltage protection on all outputs.
Unit latches off when overvoltage is detected.
AC input must be recycled to reset.
Maximum + 0.5V
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
System shutdown due to excessive internal temperature, automatic reset.
Open collector global Output Good signal. The signal activates when any of the outputs drop below 5%.
Open collector signal. Time before regulation dropout due to loss of input
power. May be used as independent PSOK signal in redundant applications.
5
Available on all outputs. Accuracy of shared current with up to 6 parallel units.
Single wire current share.
10
Available on all outputs. Total voltage compensation for cable losses with
respect to the main output.
500
UNITS
mS
%
mV
SAFETY, REGULATORY, AND EMI SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
Agency Approvals
UL1950.
CSA 22.2 NO. 234/950.
EN60950 (TÜV).
Dielectric Withstand Voltage Input to output per EN60950.
Electromagnetic Interference FCC CFR title 47 Part 15 Sub-Part B - Conducted.
EN55022 / CISPR 22 Conducted.
ESD Susceptibility
Per EN61000-4-2, level 4.
Radiated Susceptibility
Per EN61000-4-3, level 3.
EFT/Burst
Per EN61000-4-4, level 3.
Input Transient Protection
Per EN61000-4-5, class 3.
Insulation Resistance
Input to output.
MIN
Line to Line
Line to Ground
2600
B
B
8
10
±2
1
2
TYP MAX UNITS
Approved
VDC
Class
kV
V/M
kV
kV
10 M
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
2









No Preview Available !

NET1-4112 Даташит, Описание, Даташиты
NET1 SERIES
ENVIRONMENTAL SPECIFICATIONS
PARAMETER
Altitude
Operating Temperature
Storage Temperature
Temperature Coefficient
Relative Humidity
Shock
Vibration
CONDITIONS/DESCRIPTION
Operating.
Non-Operating.
0°C to 70°C (after 15-minute warmup).
Non-Condensing.
Peak acceleration.
Random vibration, 10 Hz to 2 kHz, 3 axis.
MECHANICAL
DESCRIPTION
Metric Mounting
Size
NOTES
M4 x 0.7 mounting inserts: 2 mounting surfaces
AdvaRnceeledasPeroduct
MIN
At 100% load 0
-40
5
TYP
±0.02
MAX
10k
40k
50
85
±0.05
95
20
6
UNITS
ASL Ft.
ASL Ft.
°C
°C
%/°C
%RH
GPK
GRMS
SIZE IMPACT
7.00" x 4.50" x 1.35"
(177.8mm x 114.3mm x 34.3mm)
3










Скачать PDF:

[ NET1-4112.PDF Даташит ]

Номер в каталогеОписаниеПроизводители
NET1-4112Currents Over 100 AmpsPower-One
Power-One

Номер в каталоге Описание Производители
TL431

100 мА, регулируемый прецизионный шунтирующий регулятор

Unisonic Technologies
Unisonic Technologies
IRF840

8 А, 500 В, N-канальный МОП-транзистор

Vishay
Vishay
LM317

Линейный стабилизатор напряжения, 1,5 А

STMicroelectronics
STMicroelectronics

DataSheet26.com    |    2020    |

  Контакты    |    Поиск