DataSheet26.com

WD1003 PDF даташит

Спецификация WD1003 изготовлена ​​​​«Western Digital» и имеет функцию, называемую «User Guide».

Детали детали

Номер произв WD1003
Описание User Guide
Производители Western Digital
логотип Western Digital логотип 

4 Pages
scroll

No Preview Available !

WD1003 Даташит, Описание, Даташиты
WD1002
WD1003
WD1002
WD1003
USER’S GUIDE
800-1910 (REV. 4-87)









No Preview Available !

WD1003 Даташит, Описание, Даташиты
DOCUMENT SCOPE
This document describes the hardware and software in-
stallation of the following boards:
WD1002-WAH Winchester Disk Controller
WDl002-WA2 Winchester/Floppy Disk Controller
WDl003-WAH Winchester Disk Controller
WDl003-WA2 Winchester/Floppy Disk Controller
NOTE
These controllers are designed for use in IBM Personal
computer ATs or other AT-compatible computers with a 16-
bit data bus.
The use of the term controller refers to all boards described
within this document. When a specific reference is made to a
particular board. the appropriate WD part number is used.
HARDWARE INSTALLATION
This section briefly describes installation of your hardware. If
the disk drive(s) is(are) being installed internally, it is best to
locate the controller in the nearest available expansion slot to
the drive.
CAUTION
Handle the controller board by the ends of the
board. Some of the chips are static sensitive and
damage may occur If the board is incorrectly
handled.
NOTE
Only verify the jumper settings in Step 1. Modification of the
standard factory jumper settings on any equipment described
in this document is rarely necessary. Modify jumpers only
under the direction of a qualified individual; i.e., your dealer.
1. Verify controller jumper settings. Refer to pages 3
through 6 for jumper setting information.
2. Verify termination on last drive. Verify proper setting of
drive select switches on drive; i.e., set the drive select
switches for drive select 1 or 2. Refer to your system
owner's manual for information about proper drive
termination and select switches.
3. Remove the blank expansion slot bracket. Put the bracket
away and save it for possible future use. The screw will
be used to hold the new controller board in place.
1
4. Attach 34-pin control connector pin 1 to J1 (J5 for
WDl002-WA2 or WDl003-WA2) pin 1. Pin 1 is in the
lower left hand corner of J1. Pin 1 is in the upper left
hand corner of J5.
5. Connect control cable to drive.
6. Attach 20-pin data connector to J2 (drive C or 1) for the
WD1002-WAH or WD1003-WAH (J4 for WD1002-
WA2 or WD1003-WA2).
7. Attach 20-pin data connector to J3 (Drive D or 2).
8. Connect data cables to drives.
9. Attach 34-pin floppy cable connector to J1. Connect
cable to floppy drive. This step applies to WD1002-WA2
and WDl003-WA2 users only.
10. Attach Winchester activity LED connector to J6 for all
controllers except the WDl002-WAH. The reference
designator for the Winchester activity LED connector on
the WD1002-WAH is J4.
11. Install the controller board into the expansion slot. Make
sure that the board is seated properly by pressing down
on both ends of the board. Secure the board with the
bracket screw.
12. Remove or disable any other floppy controller in your
system IF YOU ARE INSTALLING A WD1002-
WA2 OR WD1003-WA2.
2
WD 1002-WAH JUMPER SETTINGS
JUMPER
W1
W2
W2
PIN
CONNECTS
1 to 2
2 to 3
L
NL
DESCRIPTION
NOTE
DO NOT MOVE JUMPER W1 UNLESS YOUR
OPERATING SYSTEM IS CONFIGURED TO
ACCEPT TWO HARD DISK CONTROLLERS.
CERTAIN OPERATING SYSTEMS SUPPORT
TWO CONTROLLERS IN THE SAME
SYSTEM. IBM DOS AND MANY IBM-
COMPATIBLE OPERATING SYSTEMS DO
NOT SUPPORT THIS FEATURE.
Primary/secondary I/O address jumper.
Standard factory setting. Jumper in this position
selects base primary addresses IF0 hex thru IF7
and 3F6 hex thru 3F7 hex.
Jumper in this position selects base secondary
addresses 170 hex thru 177 hex and 376 hex thru
377 hex.
Latched Status Register Jumper
Standard factory setting. Current drive in use is
continuously selected. The Winchester Activity
LED remains continuously lit even though the
drive is not constantly accessed by the host. Used
for IBM Personal Computer ATs.
Current drive in use is selected only when the
WD1002-WAH is communicating with the drive.
The Winchester Activity LED only lights when the
controller accesses the drive. Used for Compaq
286 computers.
WD1002–WAH JUMPER LOCATIONS
3









No Preview Available !

WD1003 Даташит, Описание, Даташиты
WD1002-WA2 JUMPER SETTINGS
PIN
CONNECTS
E2 to E3
E5 to E6
El to E2
E4 to E5
E7 to E8
DESCRIPTION
NOTE
DO NOT MOVE PRIMARY ADDRESS JUMPERS
UNLESS YOUR OPERATING SYSTEM IS
CONFIGURED TO ACCEPT TWO HARD DISK
CONTROLLERS. CERTAIN OPERATING SYSTEMS
SUPPORT TWO CONTROLLERS IN THE SAME
SYSTEM. IBM DOS AND MANY IBM-COMPATIBLE
OPERATING SYSTEMS DO NOT SUPPORT THIS
FEATURE.
Standard factory setting. Selects primary address 3F2,
3F4/3F7 hex for the floppy disk drives.
Standard factory setting. Selects primary addresses 1FO
hex through lF7 hex, and 3F6 hex and 3F7 hex for the
Winchester diskdrives.
Selects secondary addresses 372, 374/377 hex for the
floppy disk drives.
Selects secondary addresses 170 hex through I 77 hex and
376 hex and 377 hex for the Winchester disk drives.
Jumper must he installed at all times. DO NOT
REMOVE.
WD1003-WA2 JUMPER SETTINGS
JUMPER
W1
W2
W3
W4
W5
W6
POSITION
No jumper
Jumper
No Jumper
Jumper
No jumper
Jumper
Jumper 2-3
Jumper 1-2
Jumper 2-3
Jumper 1-2
Jumper 2-3
Jumper 1-2
FUNCTION
Status Read is non-latched. Dynamic drive select; i.e..
SELECT = DRIVE BUSY. Used for Compaq 286s.
Standard factory setting. Status read is latched. Static
drive select (SELECT asserted except during RESET).
Used for IBM Personal Computer ATs.
NOTE
Do NOT MOVE PRIMARY ADDRESS JUMPERS
UNLESS YOUR OPERATING SYSTEM IS
CONFIGURED TO ACCEPT TWO HARD DISK
CONTROLLERS. CERTAIN OPERATING
SYSTEMS SUPPORT TWO CONTROLLERS IN
THE SAME SYSTEM. IBM DOS AND MANY IBM
COMPATIBLE OPERATING SYSTEMS DO NOT
SUPPORT THIS FEATURE
Standard factory setting. Primary addresses selected.
Secondary addresses selected.
This configuration used with WD1lC00A-22 or when
W5, pins 2 and 3 are jumpered.
Required only on early units with WD11C00-22 and
W5. pins 1-2 jumpered. DO NOT JUMPER WITH
WD11C00A-22 INSTALLED.
Standard factory setting. Ties firmware sense bit input
high
Supports 2 head. 612 cylinder second drive with
standard system setup for 4 head. 306 cylinder drive.
Standard factory setting.
Internal signal of Power-up circuit controls WG enable.
Standard factory setting. Ties input high.
Ties input low. The 35 µsec step rate cannot be selected
with W6 in this position. Instead, the 16 µsec step rate is
selected.
45










Скачать PDF:

[ WD1003.PDF Даташит ]

Номер в каталогеОписаниеПроизводители
WD1002User GuideWestern Digital
Western Digital
WD1002-05Winchester Floppy ControllerWestern Digital
Western Digital
WD1002-SHDWinchester Controller OEM ManualWestern Digital
Western Digital
WD1003User GuideWestern Digital
Western Digital

Номер в каталоге Описание Производители
TL431

100 мА, регулируемый прецизионный шунтирующий регулятор

Unisonic Technologies
Unisonic Technologies
IRF840

8 А, 500 В, N-канальный МОП-транзистор

Vishay
Vishay
LM317

Линейный стабилизатор напряжения, 1,5 А

STMicroelectronics
STMicroelectronics

DataSheet26.com    |    2020    |