DataSheet26.com

HMC6052 PDF даташит

Спецификация HMC6052 изготовлена ​​​​«Honeywell» и имеет функцию, называемую «INTEGRATED COMPASS SENSOR».

Детали детали

Номер произв HMC6052
Описание INTEGRATED COMPASS SENSOR
Производители Honeywell
логотип Honeywell логотип 

6 Pages
scroll

No Preview Available !

HMC6052 Даташит, Описание, Даташиты
Integrated Compass Sensor
HMC6052
The Honeywell HMC6052 is a 2-axis Magneto-Resistive sensor
plus amplifiers and analog support features essential for
compassing and low magnetic field sensing. The product is
offered in a 14-pin surface mount 3.5mm by 3.5mm LCC
package. Two channels of amplified sensor signals with a set
switch function allow compass system designers to have a
compact, easy to implement solution. Applications for the
HMC6052 include electronic compassing, and magnetometry.
Honeywell continues to maintain product excellence and
performance by introducing innovative solid-state magnetic
sensor solutions. These are highly reliable, top performance
products that are delivered when promised. Honeywell’s magnetic
sensor products provide real solutions you can count on.
Preliminary Information
FEATURES
BENEFITS
4 2 Axis AMR Magnetic Sensor (HMC1052)
w/ Integrated Amplifiers & Set Circuit
4 Single Die in a Surface Mount Package
(3.5 x 3.5 x 0.8 mm 14-pin LCC)
4 Minimal Support Components
4 Field Range +/- 2 gauss
4 Low Voltage Operation (2.5 to 3.6 V)
4 Precision Magnetic Field Measurement
4 Minimal Detectable Field (80 micro-gauss)
4 Lead Free Package Construction
4 Complete Analog Solution Optimized for Compassing. Eliminates
Need for External Amplifiers and Most Discrete Components
4 Optimized for Smallest Footprint and Easy Integration
4 Only Two Capacitors to Complete the Analog Signal Processing
4 Optimized for Compass Applications in Hand-Held or Hard Iron
Environment
4 Compatible for Battery Powered Applications
4 User’s ADC Resolution Limits the Accuracy of the Outputs
4 Permits Accurate Compassing and Magnetic Field Measurement
4 Complies with Current Environmental Standards (RoHS)









No Preview Available !

HMC6052 Даташит, Описание, Даташиты
HMC6052
HMC6052 SPECIFICATIONS
Characteristics
Conditions*
Supply Voltage
Vsupply, Vbridge to GND
Supply Current
Vsupply to GND
Bridge Current
A, B bridges
Field Range
Full scale (FS), Vsupply, Vbridge = 3.0 volts
Field Sensitivity
Vsupply, Vbridge = 3.0 volts
Zero Field Output
Vsupply, Vbridge = 3.0 volts
Load Resistance
Applied to OUTA, OUTB
Load Capacitance
Applied to OUTA, OUTB
Bandwidth
system signal output (lower limit = DC)
Noise Floor
Vsupply, Vbridge = 3.0V
SINL, SINH toggle before measurement
Linearity
Vsupply, Vbridge=3.0V, Field +/- 0.5 Oe
Disturbing Field
Sensitivity starts to degrade.
Use set pulse to restore sensitivity.
Max. Exposed
No perming effect on zero field reading
Field
Operating
Ambient
Temperature
Storage
Ambient, Unbiased
Temperature
Sensitivity
Tempco
Output Voltage
Tempco
Sensitivity Ratio of
Sensors
TA= 0 to 70°C
X,Y sensor
Sensitive direction in X and Y sensors
Orthogonality
* Tested at 25°C except stated otherwise.
Min
2.5
-2.0
6000
-
1
20
-45
-55
-3000
95
Typ
3.0
6
0.5
1.5
10,000
1
0.4
-2700
± 500
100
Max
3.6
9
+2.0
-
100
10000
120
150
-2400
105
0.01
Units
Volts
mA
mA
gauss
V/gauss
volts
ohms
pF
kHz
mV
%FS
Gauss
Gauss
°C
°C
ppm/°C
ppm/°C
%
Degree
Characteristics
Conditions*
Set Strap Circuit
Input Logic Voltage Measured from SIN to GND (Vsupply = 3.0v)
Low “0” State
High “1” State
Input Logic Current
Offset Straps
Resistance
Measured from OFF+ to OFF-
Offset
DC Current
Constant
Field applied in sensitive directions
Resistance
Tempco
* Tested at 25°C except stated otherwise.
TA= 0 to 70°C
2
Min
12
3500
Typ
0.3
2.5
0
15
10
3900
Max
Units
volts
volts
µA
18 ohms
mA/gauss
4300 ppm/°C
www.honeywell.com









No Preview Available !

HMC6052 Даташит, Описание, Даташиты
HMC6052
Pin Configurations
23 4 56
OFF+ 1
OUTB 14
B
A
7 SINL
8 VSR
13 12 11 10 9
Bottom View
Pin Descriptions
HMC6052
Pin Name
Description
1 OFF+
Offset Strap Positive
2 N/C
No Connect
3 VBRIDGE
Positive Voltage Supply (2.7 to 3.6 volts) to Sensor Bridges
4 OFF-
Offset Strap Negative
5 SC-
Set Strap Capacitor Negative
6 S/R+
Set/Reset Strap Positive (test point)
7 SINL
Set Strap Logic Input (normally low)
8 VSR
Set Strap Reservoir Capacitor
9 SC+
Set Strap Capacitor Positive
10 SINH
Set Strap Logic Input (normally high)
11 VSUPPLY
Positive Voltage Supply (2.7 to 3.6 volts) to Signal Conditioning
12 GND
Negative Voltage Supply and Signal Ground Reference
13 OUTA
Output Voltage for Sensor A
14 OUTB
Output Voltage for Sensor B
www.honeywell.com
3










Скачать PDF:

[ HMC6052.PDF Даташит ]

Номер в каталогеОписаниеПроизводители
HMC6052INTEGRATED COMPASS SENSORHoneywell
Honeywell
HMC605LP3GaAs PHEMT MMIC LOW NOISE AMPLIFIER w/ BYPASS MODEHittite Microwave
Hittite Microwave
HMC605LP3EGaAs PHEMT MMIC LOW NOISE AMPLIFIER w/ BYPASS MODEHittite Microwave
Hittite Microwave

Номер в каталоге Описание Производители
TL431

100 мА, регулируемый прецизионный шунтирующий регулятор

Unisonic Technologies
Unisonic Technologies
IRF840

8 А, 500 В, N-канальный МОП-транзистор

Vishay
Vishay
LM317

Линейный стабилизатор напряжения, 1,5 А

STMicroelectronics
STMicroelectronics

DataSheet26.com    |    2020    |

  Контакты    |    Поиск