DataSheet26.com

74AS04 PDF даташит

Спецификация 74AS04 изготовлена ​​​​«ETC» и имеет функцию, называемую «SN74AS04».

Детали детали

Номер произв 74AS04
Описание SN74AS04
Производители ETC
логотип ETC логотип 

6 Pages
scroll

No Preview Available !

74AS04 Даташит, Описание, Даташиты
www.DataSheet4U.com
SN54ALS04B, SN54AS04, SN74ALS04B, SN74AS04
HEX INVERTERS
Package Options Include Plastic
Small-Outline (D) Packages, Ceramic Chip
Carriers (FK), and Standard Plastic (N) and
Ceramic (J) 300-mil DIPs
description
These devices contain six independent hex
inverters. They perform the Boolean function
Y = A.
The SN54ALS04B and SN54AS04 are
characterized for operation over the full military
temperature range of – 55°C to 125°C. The
SN74ALS04B and SN74AS04 are characterized
for operation from 0°C to 70°C.
FUNCTION TABLE
(each inverter)
INPUT OUTPUT
AY
HL
LH
SDAS063B – APRIL 1982 – REVISED DECEMBER 1994
SN54ALS04B, SN54AS04 . . . J PACKAGE
SN74ALS04B, SN74AS04 . . . D OR N PACKAGE
(TOP VIEW)
1A
1Y
2A
2Y
3A
3Y
GND
1
2
3
4
5
6
7
14 VCC
13 6A
12 6Y
11 5A
10 5Y
9 4A
8 4Y
SN54ALS04B, SN54AS04 . . . FK PACKAGE
(TOP VIEW)
3 2 1 20 19
2A 4
18 6Y
NC 5
17 NC
2Y 6
16 5A
NC 7
15 NC
3A 8
14 5Y
9 10 11 12 13
logic symbol
12
1A 1 1Y
34
2A 2Y
56
3A 3Y
98
4A 4Y
11 10
5A 5Y
13 12
6A 6Y
This symbol is in accordance with ANSI/IEEE Std 91-1984
and IEC Publication 617-12.
Pin numbers shown are for the D, J, and N packages.
NC – No internal connection
logic diagram (positive logic)
1
1A
2
1Y
3
2A
4
2Y
5
3A
6
3Y
9
4A
8
4Y
11
5A
10
5Y
13
6A
12
6Y
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
Copyright © 1994, Texas Instruments Incorporated
1









No Preview Available !

74AS04 Даташит, Описание, Даташиты
SN54ALS04B, SN54AS04, SN74ALS04B, SN74AS04
www.DataSHhEeeXt4UIN.coVmERTERS
SDAS063B – APRIL 1982 – REVISED DECEMBER 1994
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Input voltage, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Operating free-air temperature range, TA: SN54ALS04B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 55°C to 125°C
SN74ALS04B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
VCC
VIH
Supply voltage
High-level input voltage
VIL Low-level input voltage
IOH High-level output current
IOL Low-level output current
TA Operating free-air temperature
Applies over – 55°C to 70°C temperature range
§ Applies over 70°C to 125°C temperature range
SN54ALS04B
MIN NOM MAX
4.5 5 5.5
2
0.8‡
0.7§
– 0.4
4
– 55 125
SN74ALS04B
MIN NOM MAX
4.5 5 5.5
2
0.8
UNIT
V
V
V
– 0.4 mA
8 mA
0 70 °C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
SN54ALS04B
MIN TYP¶ MAX
SN74ALS04B
MIN TYP¶ MAX UNIT
VIK VCC = 4.5 V,
II = –18 mA
–1.2 –1.2 V
VOH
VCC = 4.5 V to 5.5 V,
IOH = – 0.4 mA
VCC – 2
VCC – 2
V
VOL
VCC = 4.5 V
IOL = 4 mA
IOL = 8 mA
0.25 0.4
0.25 0.4
V
0.35 0.5
II
VCC = 5.5 V,
VI = 7 V
0.1 0.1 mA
IIH VCC = 5.5 V, VI = 2.7 V
20 20 µA
IIL VCC = 5.5 V,
IO# VCC = 5.5 V,
VI = 0.4 V
VO = 2.25 V
– 0.1
– 0.1 mA
– 20 – 112 – 30 – 112 mA
ICCH
VCC = 5.5 V,
VI = 0
0.65 1.1
0.65 1.1 mA
ICCL
VCC = 5.5 V,
VI = 4.5 V
2.9 4.4
2.9 4.2 mA
¶ All typical values are at VCC = 5 V, TA = 25°C.
# The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, IOS.
2 POST OFFICE BOX 655303 DALLAS, TEXAS 75265









No Preview Available !

74AS04 Даташит, Описание, Даташиты
www.DataSheet4U.com
SN54ALS04B, SN54AS04, SN74ALS04B, SN74AS04
HEX INVERTERS
SDAS063B – APRIL 1982 – REVISED DECEMBER 1994
switching characteristics (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
VCC = 4.5 V to 5.5 V,
CL = 50 pF,
RL = 500 ,
TA = MIN to MAX†
SN54ALS04B SN74ALS04B
MIN MAX MIN MAX
tPLH
tPHL
A
3 17
Y
2 13
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
3
2
11
8
UNIT
ns
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Input voltage, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Operating free-air temperature range, TA: SN54AS04 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 55°C to 125°C
SN74AS04 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
VCC
VIH
VIL
IOH
IOL
TA
Supply voltage
High-level input voltage
Low-level input voltage
High-level output current
Low-level output current
Operating free-air temperature
SN54AS04
MIN NOM MAX
4.5 5 5.5
2
0.8
–2
20
– 55 125
SN74AS04
MIN NOM MAX
4.5 5 5.5
2
0.8
–2
20
0 70
UNIT
V
V
V
mA
mA
°C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
SN54AS04
MIN TYP§ MAX
SN74AS04
MIN TYP§ MAX UNIT
VIK VCC = 4.5 V,
II = –18 mA
–1.2 –1.2 V
VOH
VCC = 4.5 V to 5.5 V,
IOH = – 2 mA
VCC – 2
VCC – 2
V
VOL
VCC = 4.5 V,
IOL = 20 mA
0.35 0.5
0.35 0.5 V
II
VCC = 5.5 V,
VI = 7 V
0.1 0.1 mA
IIH VCC = 5.5 V, VI = 2.7 V
20 20 µA
IIL VCC = 5.5 V,
IO¶ VCC = 5.5 V,
VI = 0.4 V
VO = 2.25 V
– 0.5
– 0.5 mA
– 30 – 112 – 30 – 112 mA
ICCH
VCC = 5.5 V,
VI = 0
3 4.8
3 4.8 mA
ICCL
VCC = 5.5 V,
VI = 4.5 V
14 26.3
14 26.3 mA
§ All typical values are at VCC = 5 V, TA = 25°C.
¶ The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, IOS.
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
3










Скачать PDF:

[ 74AS04.PDF Даташит ]

Номер в каталогеОписаниеПроизводители
74AS00Quadruple 2-Input Positive-NAND GatesTexas Instruments
Texas Instruments
74AS04Hex InvertersTexas Instruments
Texas Instruments
74AS04SN74AS04ETC
ETC
74AS08Quadruple 2-Input Positive-AND GatesTexas Instruments
Texas Instruments

Номер в каталоге Описание Производители
TL431

100 мА, регулируемый прецизионный шунтирующий регулятор

Unisonic Technologies
Unisonic Technologies
IRF840

8 А, 500 В, N-канальный МОП-транзистор

Vishay
Vishay
LM317

Линейный стабилизатор напряжения, 1,5 А

STMicroelectronics
STMicroelectronics

DataSheet26.com    |    2020    |

  Контакты    |    Поиск