DESCRIPTION
The S742 is a bi-directional, single-pole, single-throw, normally open multipurpose relay. The circuit is composed of one LED on the input
side which activates an optically coupled IC on the output - controlling the firing angle of two back-to-back SCRs. This circuit assures no
false triggering under most adverse conditions, and a tight zero-volt window not exceeding 5V.
FEATURES
Zero-Volt Cross Switching
High transient immunity
600V blocking voltage
1.2A maximum continuous current
Low input control current
High input-to-output isolation
Solid state reliability
APPLICATIONS
Valve control
Solenoids
Home appliances
Metering equipment
Heating elements
Gas pump control circuitry
OPTIONS/SUFFIXES*
ABSOLUTE MAXIMUM RATINGS*
www.DataSheet4U.com-H High Output Isolation
PARAMETER
UNIT MIN TYP MAX
-S Surface Mount Option
Storage Temperature
°C -55
125
-TR Tape and Reel
NOTE: Suffixes listed above are not included in marking on
device for part number identification.
Operating Temperature
°C -40
Continuous Input Current mA
85
40
SCHEMATIC DIAGRAM
Transient Input Current
mA
400
Reverse Input Control
Voltage
Output Power Dissipation
V
W
6
1.2
*The values indicated are absolute stress ratings. Functional operation of the
device is not implied at these or any conditions in excess of those defined in
electrical characteristics section of this document. Exposure to Absolute
Ratings may cause permanent damage to the device and may adversely
affect reliability.
APPROVALS
BABT CERTIFICATE #607837:
BS EN 60950, BS EN 41003, BS EN 60065
UL FILE #E90096
© 2004 Solid State Optronics • San José, CA
www.ssousa.com • +1.408.293.4600
Page 1 of 5
S742
rev 1.40 (10/25/2004)
www.DataSheet4U.com









No Preview Available !

S742 Даташит, Описание, Даташиты
www.DataSheet4U.com
S742
1 Form A
Solid State Relay
ELECTRICAL CHARACTERISTICS - 25°C
PARAMETER
UNIT MIN TYP MAX TEST CONDITIONS
INPUT SPECIFICATIONS
LED Forward Voltage
LED Reverse Voltage
Must Operate Current
Junction Capacitance
OUTPUT SPECIFICATIONS
V
V
mA
pF
1.2 1.5 If = 10mA
6 12
Ir = 10uA
2.5 5 Io = 1.2A, resistive load
5 Vf = 0V
Blocking Voltage
V 600
Io = 600uA
Continuous Load Current
A
1.2 If = 5mA
Surge Current Rating
A
10 T = 16ms
Holding Current
mA
10
On-Voltage V 1.2 Io = 1.2A
Voltage Across Load at Turn-On
www.DataSheet4U.comLeakage Current
V
µA
5 If = 5mA
100 250 Vo = 250V
Thermal Resistance
°C/W
80
Power Factor
0.3
Critical Rate of Rise (dV/dt)
COUPLED SPECIFICATIONS
V / µ s 400
Isolation Voltage
-H Suffix
Isolation Resistance
Coupled Capacitance
V 2500
V 3750
G 100
pF 6
T = 1 minute
T = 1 minute
© 2004 Solid State Optronics • San José, CA
www.ssousa.com • +1.408.293.4600
Page 2 of 5
S742
rev 1.40 (10/25/2004)
www.DataSheet4U.com









No Preview Available !

S742 Даташит, Описание, Даташиты
www.DataSheet4U.com
S742
1 Form A
Solid State Relay
PERFORMANCE DATA
S742
Maximum Load Current vs. Temperature
1500
1000
500
0
Tem perature (C)
S742
Typical Blocking Voltage Distribution
N = 100, Ambient Temperature = 25°C
40
30
20
10
0
600 610 620 630 640 650 660 670
Blocking Voltage (V)
ZERO-VOLT SWITCHING
This solid state relay has been designed with a driver circuit that controls the operation of two back-to-back silicon controlled rectifiers
(SCRs), each responsible for one half of the AC cycle. If an AC signal is examined, the turn on, turn off and zero-volt switching can be seen.
www.DataSheet4U.comFigure 1 shows a typical 60 Hz, 120Vac signal with a corresponding relay input signal:
1
Relay Input Signal is
Turned On.
5 Relay Input Signal is
Turned Off.
Input Signal
5V
Threshold
2
SCR #1 Turns On when
5V threshold is reached.
6 SCR #1 and Relay Turn
Off at Zero Volts.
3
SCR #1 Turns Off,
SCR #2 Turns On
at Zero Volts.
4
SCR #2 Turns Off,
SCR #1 Turns On
at Zero Volts.
Figure 1 shows the sequence of zero-volt switching operation. At Stage 1, an input signal is applied to the relay. The relay will not turn on
until the threshold voltage of 5V is reached. Once this point is reached (Stage 2), SCR #1 (designated as the SCR which controls positive
AC voltage) turns on. However, SCR #1 only conducts for an instant, as the cycle quickly crosses zero. At this point (Stage 3), SCR #1 will
turn off and SCR #2 (negative AC voltage) turns on. Likewise, at the next zero cross (Stage 4), SCR #2 will turn off and SCR #1 conducts
again. Even though the input signal is terminated at Stage 5, the relay will continue to conduct (typical SCR behavior) until Stage 6, when
SCR #1 crosses zero and ceases to conduct. Please note that turn on can likewise begin on the negative phase of the AC cycle with a -5V
threshold, though only the positive phase is shown here.
© 2004 Solid State Optronics • San José, CA
www.ssousa.com • +1.408.293.4600
Page 3 of 5
S742
rev 1.40 (10/25/2004)
www.DataSheet4U.com










Скачать PDF:

[ S742.PDF Даташит ]

Номер в каталогеОписаниеПроизводители
S7421 Form A Solid State RelaySolid State Optronic
Solid State Optronic
S742-X1 Form A Solid State RelaySolid State Optronic
Solid State Optronic
S7481Si PIN photodiodeHamamatsu
Hamamatsu
S7482Si PIN photodiodeHamamatsu
Hamamatsu

Номер в каталоге Описание Производители
TL431

100 мА, регулируемый прецизионный шунтирующий регулятор

Unisonic Technologies
Unisonic Technologies
IRF840

8 А, 500 В, N-канальный МОП-транзистор

Vishay
Vishay
LM317

Линейный стабилизатор напряжения, 1,5 А

STMicroelectronics
STMicroelectronics

DataSheet26.com    |    2020    |

  Контакты    |    Поиск