Features
z Four-channel Seismic Acquisition Node
– CS3301 geophone amplifiers (2x)
– CS3302 hydrophone amplifiers (2x)
– CS5372 dual ∆Σ modulators (2x)
– CS5376A quad digital filter (1x)
– CS4373A ∆Σ test DAC (1x)
– Precision voltage reference
– Clock recovery PLL
z On-board Microcontroller
– SPI™ interface to digital filter
– USB communication with PC
z PC Evaluation Software
– Register setup & control
– FFT frequency analysis
– Time domain analysis
– Noise histogram analysis
General Description
The CDB5376 board is used to evaluate the functionality
and performance of the Cirrus Logic multichannel seis-
mic chip set. Data sheets for the CS3301, CS3302,
CS4373A, CS5371/72, and CS5376A devices should be
consulted when using the CDB5376 evaluation board.
Screw terminals connect external differential geophone
or hydrophone sensors to the analog inputs of the mea-
surement channels. An on-board test DAC creates
precision differential analog signals for in-circuit perfor-
mance testing without an external signal source.
The evaluation board includes an 8051-type microcon-
troller with hardware SPIand USB serial interfaces.
The microcontroller communicates with the digital filter
via SPI and with the PC evaluation software via USB.
The PC software controls register and coefficient initial-
ization and performs time domain, histogram, and FFT
frequency analysis on captured data.
ORDERING INFORMATION
CDB5376
Evaluation Board
www.cirrus.com
Copyright © Cirrus Logic, Inc. 2006
(All Rights Reserved)
MAR ‘06
DS612DB2









No Preview Available !

CDB5376 Даташит, Описание, Даташиты
CDB5376
Contacting Cirrus Logic Support
For all product questions and inquiries contact a Cirrus Logic Sales Representative. To find the one nearest to you
go to www.cirrus.com
IMPORTANT NOTICE
Cirrus Logic, Inc. and its subsidiaries ("Cirrus") believe that the information contained in this document is accurate and reliable. However, the information is subject
to change without notice and is provided "AS IS" without warranty of any kind (express or implied). Customers are advised to obtain the latest version of relevant
information to verify, before placing orders, that information being relied on is current and complete. All products are sold subject to the terms and conditions of sale
supplied at the time of order acknowledgment, including those pertaining to warranty, indemnification, and limitation of liability. No responsibility is assumed by Cirrus
for the use of this information, including use of this information as the basis for manufacture or sale of any items, or for infringement of patents or other rights of third
parties. This document is the property of Cirrus and by furnishing this information, Cirrus grants no license, express or implied under any patents, mask work rights,
copyrights, trademarks, trade secrets or other intellectual property rights. Cirrus owns the copyrights associated with the information contained herein and gives
consent for copies to be made of the information only for use within your organization with respect to Cirrus integrated circuits or other products of Cirrus. This con-
sent does not extend to other copying such as copying for general distribution, advertising or promotional purposes, or for creating any work for resale.
CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF DEATH, PERSONAL INJURY, OR SEVERE PROP-
ERTY OR ENVIRONMENTAL DAMAGE ("CRITICAL APPLICATIONS"). CIRRUS PRODUCTS ARE NOT DESIGNED, AUTHORIZED OR WARRANTED FOR
USE IN AIRCRAFT SYSTEMS, MILITARY APPLICATIONS, PRODUCTS SURGICALLY IMPLANTED INTO THE BODY, AUTOMOTIVE SAFETY OR SECURITY
DEVICES, LIFE SUPPORT PRODUCTS OR OTHER CRITICAL APPLICATIONS. INCLUSION OF CIRRUS PRODUCTS IN SUCH APPLICATIONS IS UNDER-
STOOD TO BE FULLY AT THE CUSTOMER'S RISK AND CIRRUS DISCLAIMS AND MAKES NO WARRANTY, EXPRESS, STATUTORY OR IMPLIED, INCLUD-
ING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE, WITH REGARD TO ANY CIRRUS PRODUCT THAT
IS USED IN SUCH A MANNER. IF THE CUSTOMER OR CUSTOMER'S CUSTOMER USES OR PERMITS THE USE OF CIRRUS PRODUCTS IN CRITICAL
APPLICATIONS, CUSTOMER AGREES, BY SUCH USE, TO FULLY INDEMNIFY CIRRUS, ITS OFFICERS, DIRECTORS, EMPLOYEES, DISTRIBUTORS AND
OTHER AGENTS FROM ANY AND ALL LIABILITY, INCLUDING ATTORNEYS' FEES AND COSTS, THAT MAY RESULT FROM OR ARISE IN CONNECTION
WITH THESE USES.
Cirrus Logic, Cirrus, and the Cirrus Logic logo designs are trademarks of Cirrus Logic, Inc. All other brand and product names in this document may be trademarks
or service marks of their respective owners.
Windows, Windows XP, Windows 2000, and Windows NT are trademarks or registered trademarks of Microsoft Corporation.
Intel and Pentium are registered trademarks of Intel Corporation.
SPI is a trademark of Motorola, Inc.
I2C (I2C) is a registered trademark of Philips Semiconductor Corporation.
USBExpress is a registered trademark of Silicon Laboratories, Inc.
2 DS612DB2









No Preview Available !

CDB5376 Даташит, Описание, Даташиты
CDB5376
TABLE OF CONTENTS
1. INITIAL SETUP ......................................................................................................................... 5
1.1 Kit Contents ....................................................................................................................... 5
1.2 Hardware Setup ................................................................................................................. 5
1.2.1 Default Jumper Settings ........................................................................................ 6
1.2.2 Default DIP Switch Settings ................................................................................. 8
1.3 Software Setup .................................................................................................................. 9
1.3.1 PC Requirements .................................................................................................. 9
1.3.2 Seismic Evaluation Software Installation .............................................................. 9
1.3.3 USBXpress Driver Installation ............................................................................... 9
1.3.4 Launching the Seismic Evaluation Software ....................................................... 10
1.4 Self-testing CDB5376 ...................................................................................................... 11
1.4.1 Noise test ............................................................................................................ 11
1.4.2 Distortion Test ..................................................................................................... 12
2. HARDWARE DESCRIPTION ................................................................................................. 13
2.1 Block Diagram ................................................................................................................ 13
2.2 Analog Hardware ............................................................................................................. 14
2.2.1 Analog Inputs ...................................................................................................... 14
2.2.2 Differential Amplifiers .......................................................................................... 17
2.2.3 Delta-Sigma Modulators ..................................................................................... 18
2.2.4 Delta-Sigma Test DAC ........................................................................................ 19
2.2.5 Voltage Reference .............................................................................................. 20
2.3 Digital Hardware .............................................................................................................. 21
2.3.1 Digital Filter ......................................................................................................... 21
2.3.2 Interface CPLD ................................................................................................... 23
2.3.3 Digital Control Signals ......................................................................................... 25
2.3.4 Microcontroller .................................................................................................... 25
2.3.5 Phase Locked Loop ............................................................................................ 27
2.3.6 RS-485 Telemetry ............................................................................................... 29
2.3.7 UART Connection ............................................................................................... 30
2.3.8 External Connector ............................................................................................. 31
2.4 Power Supplies ................................................................................................................ 31
2.4.1 Analog Voltage Regulators ................................................................................. 31
2.4.2 Digital Voltage Regulators .................................................................................. 32
2.5 PCB Layout ..................................................................................................................... 33
2.5.1 Layer Stack ......................................................................................................... 33
2.5.2 Differential Pairs .................................................................................................. 33
2.5.3 Bypass Capacitors .............................................................................................. 34
2.5.4 Dual Row Headers .............................................................................................. 35
3. SOFTWARE DESCRIPTION .................................................................................................. 36
3.1 Menu Bar ......................................................................................................................... 36
3.2 About Panel ..................................................................................................................... 37
3.3 Setup Panel ..................................................................................................................... 38
3.3.1 USB Port ............................................................................................................. 39
3.3.2 Digital Filter ......................................................................................................... 40
3.3.3 Analog Front End ................................................................................................ 41
3.3.4 Test Bit Stream ................................................................................................... 41
3.3.5 Gain/Offset .......................................................................................................... 42
3.3.6 Data Capture ....................................................................................................... 43
3.3.7 External Macros .................................................................................................. 44
3.4 Analysis Panel ................................................................................................................. 45
3.4.1 Test Select .......................................................................................................... 46
3.4.2 Statistics .............................................................................................................. 47
DS612DB2
3










Скачать PDF:

[ CDB5376.PDF Даташит ]

Номер в каталогеОписаниеПроизводители
CDB5376Multichannel Seismic Evaluation SystemCirrus Logic
Cirrus Logic
CDB5378Single-channel Seismic Evaluation SystemCirrus Logic
Cirrus Logic

Номер в каталоге Описание Производители
TL431

100 мА, регулируемый прецизионный шунтирующий регулятор

Unisonic Technologies
Unisonic Technologies
IRF840

8 А, 500 В, N-канальный МОП-транзистор

Vishay
Vishay
LM317

Линейный стабилизатор напряжения, 1,5 А

STMicroelectronics
STMicroelectronics