DataSheet26.com

HAT1500-S PDF даташит

Спецификация HAT1500-S изготовлена ​​​​«LEM» и имеет функцию, называемую «(HAT200-S - HAT1500-S) Current Transducer».

Детали детали

Номер произв HAT1500-S
Описание (HAT200-S - HAT1500-S) Current Transducer
Производители LEM
логотип LEM логотип 

3 Pages
scroll

No Preview Available !

HAT1500-S Даташит, Описание, Даташиты
Current Transducer HAT 200..1500-S
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
IPN = 200..1500 A
VOUT = ± 4 V
Electrical data
Primary nominal
r.m.s. current
IPN (A)
200
400
500
600
750
800
1000
1200
1500
Primary current
measuring range 4)
IP (A)
± 600
± 1200
± 1500
± 1800
± 2250
± 2400
± 3000
± 3000
± 3000
VC
IC
R IS
Vwww.DataSheet4U.com OUT
ROUT
R
L
Supply voltage (± 5 %) 4)
Current consumption
Isolation resistance @ 500 VDC
Output voltage @ ± IPN, RL = 10 k, TA = 25°C
Output internal resistance
Load resistance
Accuracy-Dynamic performance data
X
εL
V
OE
VOH
εVOT
TC
G
tr
f
Accuracy @ I , T = 25°C (without offset)
PN A
Linearity error 1) (0 .. ± IPN)
Electrical offset voltage, T = 25°C
A
Hysteresis offset voltage @ IP = 0;
after an excursion of 1 x I
PN
Thermal drift of VOE
Thermal drift of the gain (% of reading)
Response time @ 90% of IP
Frequency bandwidth 2) (- 3 dB)
Type
HAT 200-S
HAT 400-S
HAT 500-S
HAT 600-S
HAT 750-S
HAT 800-S
HAT 1000-S
HAT 1200-S
HAT 1500-S
± 15
± 15
> 1000
±4
100
> 10
V
mA
M
V
k
< ± 1 % of I
PN
< ± 1 % of IPN
< ± 20
mV
< ± 10
mV
< ± 1 mV/K
< ± 0.1 %/K
< 5 µs
DC .. 25 kHz
General data
T Ambient operating temperature
A
- 10 .. + 80 °C
TS Ambient storage temperature HAT 200-S, HAT 500..1500-S - 15 .. + 85 °C
HAT 400-S
- 25 .. + 85 °C
m Mass
300 g
UL94 classification
V0
Features
Hall effect measuring principle
Galvanic isolation between primary
and secondary circuit
Isolation voltage 3000 V
Low power consumption
Extended measuring range 3 x IPN
Insulated plastic case recognized
according to UL 94-V0
Advantages
Easy mounting
Small size and space saving
Only one design for wide current
ratings range
High immunity to external
interference.
Applications
DC motor drives
Switched Mode Power Supplies
(SMPS)
AC variable speed drives
Uninterruptible Power Supplies
(UPS)
Battery supplied applications
Power supplies for welding
applications
Notes :
1) Linearity data exclude the electrical offset.
2) Please refer to derating curves in the technical file to avoid excessive
core heating at high frequency.
3) Please consult characterisation report for more technical details and
application advice.
4) Operating at ±12V Vc < ±15V will reduce the measuring range.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
LEM Industrial
051011/9
Page 1/3
www.lem.com









No Preview Available !

HAT1500-S Даташит, Описание, Даташиты
Current Transducer HAT 200..1500-S
Isolation characteristics
Rated Voltage
1000
with IEC 61010-1 standards and following conditions
- Reinforced insulation
- Over voltage category III
- Pollution degree 2
- Heterogeneous field
Vd R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
dCp Creepage distance
3
> 11
dCl Clearance distance
> 11
CTI Comparative Tracking Index (Group IIIa)
275
V
kV
mm
mm
Notes :
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
LEM Industrial
051011/9
Page 2/3
www.lem.com









No Preview Available !

HAT1500-S Даташит, Описание, Даташиты
Dimensions HAT 200..1500-S (in mm. 1 mm = 0.0394 inch)
Top view
HAT-S SERIES
HAT 500-S to 1500-S
12 12
== = =
(unit = mm)
Positive current flow
70
30.5 x 40.5
1
4
6
Front view
HAT 200-S
Mechanical characteristics
Molex 5045-04A
78 1
90
Pins arrangement
1234
(+) (-) Output 0V
30.5 x 40.5
Safety
All holes O 4.5mm
Fixation by base-plate or on bus bar
with M4 screws
General tolerance
Transducer fastening
Connection of secondary
± 1 mm
By base-plate or on
432 1
bus bar with M4Molex 5045-04A
screws.
All slots 4.5 mm
Molex 5045-04A
Pins arrangement:
12
34
This transducer must(+b) e u(-)seOdutpiunt e0Vlectric/electronic equipment
with respect to applicable stand9a9/r0d5 s and safety requirements
in accordance with the following manufacturer's operating
instructions.
Remarks
IS is positive when IP flows in the direction of the arrow.
Temperature of the primary conductor should not exceed
100°C.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can
carry hazardous voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious
damage.
This transducer is a built-in device, whose conducting parts
must be inaccessible after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
LEM Industrial
051011/9
Page 3/3
www.lem.com










Скачать PDF:

[ HAT1500-S.PDF Даташит ]

Номер в каталогеОписаниеПроизводители
HAT1500-SCurrent Transducer HAT 500~1500-SLEM
LEM
HAT1500-S(HAT200-S - HAT1500-S) Current TransducerLEM
LEM

Номер в каталоге Описание Производители
TL431

100 мА, регулируемый прецизионный шунтирующий регулятор

Unisonic Technologies
Unisonic Technologies
IRF840

8 А, 500 В, N-канальный МОП-транзистор

Vishay
Vishay
LM317

Линейный стабилизатор напряжения, 1,5 А

STMicroelectronics
STMicroelectronics

DataSheet26.com    |    2020    |