Linear Power Supplies Data Sheet
Features
www.DataSheet4U.com
Description
• RoHS compatible for all six substances
• Worldwide AC Input Capabilities:
100/120/220/230/240 VAC
• ±0.05% Output Regulation
• Low Output Ripple
• UL, CSA, and TÜV Approvals
• Mean Time Before Failure (MTBF) in Excess of
300,000 Hours
• CE marked to Low Voltage Directive
• 100% Burn-In
• 2 Year Warranty
• Overvoltage Protection (OVP) Standard on 5V
Single Outputs, Optional for other outputs
under 48V
Power-One produces the industry’s broadest selection of
Linear power supplies with output voltages from 5 volts
through 250 volts. Rugged technology and proven design
merge to create quiet, highly-regulated, dependable
DC power.
The Linear power supplies are approved to domestic and
international regulatory standards, and are CE Marked to
the Low Voltage Directive (LVD).
Overvoltage Protection Options
OVERVOLTAGE PROTECTION OPTIONS
These optional overvoltage protection modules are offered for use with
Power-One’s Linear power supplies. Each is user adjustable from 6.4V to 34V.
OVP-12G
OVP SELECTION GUIDE
MODEL
CASE SIZE
OVP MODULES REQUIRED
SINGLE
OUTPUT
B,C,N,D
E,F
(1) OVP-12G
(1) OVP-24G
DUAL
OUTPUT
AA,B,BB,CC
E
(1) OVP-12G protects both outputs
(1) OVP-24G protects both outputs
TRIPLE
OUTPUT
AA,BAA,D
CBB, 131
DBB,DCC
(1) OVP-12G protects both 12V
through 15V outputs
PEAK
CURRENT
MODELS
N,BAA,CBB
131
(1) OVP-12G protects any output
not provided with built-in OVP
NOTE: Outputs with factory built-in OVP are indicated in the Voltage/Current Rating
Chart for each model. OVP is not available for 48V through 250V models.
OVP-24G
105553 Rev. AA
Page 1 of 9
www.power-one.com

1 page




HCAA-60W-AG pdf
Linear Power Supplies Data Sheet
Input Specifications
PARAMETER
CONDITIONS/DESCRIPTION
Input Voltage - AC
(Note 1, 2)
Jumper selectable, shipped factory configured for
120VAC operation. All models must be externally
fused for proper operation. Fuse ratings are marked
on each unit. Consult factory for each unit’s fuse
requirements.
Input Frequency
AC input.
Line Regulation
Output voltage charge for a 10% line change: F case models.
HAD12, HAD15.
Outputs with adjustable three terminal regulators.
All other models.
NOTES: 1) Derate output current 10% for 50Hz operation.
2) Input voltage tolerance for 230VAC operation is +15%, -10%.
www.DataSheet4U.com
100 VAC Tap
120 VAC Tap
220 VAC Tap
240 VAC Tap
MIN
NOM
MAX UNITS
87 100 110
104
191
120
220
132
242
VAC
209 240 264
47
-0.01
-1.0
-0.5
-0.05
63
+0.01
+1.0
+0.5
+0.05
Hz
%
Output Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX UNITS
Output Adjustment
Minimum output adjustment range (Note 1).
-5 +5 %
Efficiency
5 volt outputs.
12 volt and 15 volt outputs.
24 volt and higher outputs.
45
55 %
60
Ripple and Noise
(Note 2)
F case models.
5 volt, 12 volt, and 15 volt models.
All three terminal regulator outputs.
24 volt through 250 volt models.
3.0 mVPK-PK
5.0 mVPK-PK
0.2 %PK-PK
3.0mVPK-PK plus 0.02% of output voltage, max
Load Regulation
Output change for a 50% load change: F case models.
HAD12, HAD15.
Outputs with adjustable three terminal regulators.
All other models.
-0.02
-1
-0.5
-0.05
+0.02
+1
+0.5
+0.05
%
Transient Response
Recovery time, to within 1% of initial set point due to a 50% load change.
50 μs
NOTES: 1) OUTPUT VOLTAGE ADJUSTMENTS: Output voltage adjustments can be made to within ±5% of factory setting of nominal output voltage. Locate the “Vadj”
potentiometer on the power supply PCB and use a screwdriver to adjust the output pot. The HAD12 and HAD15 3 terminal regulator outputs are not
adjustable.
2) Full load, 20MHz bandwidth.
Safety, Regulatory, and EMI Specifications
PARAMETER
Agency Approvals
Dielectric Withstand
Voltage
Electromagnetic
Interference
Leakage Current
CONDITIONS/DESCRIPTION
UL60950-1.
CSA 60950-1 “cUL”.
EN60950-1.
IEC60950-1.
Input to output.
Input to ground.
FCC CFR title 47 Part 15 Sub-Part B - conducted.
EN55022 / CISPR 22 conducted.
EN55022 / CISPR 22 radiated.
Per EN60950
(264VAC)
MIN
NOM
MAX UNITS
Approved
3000
1500
VAC
Compatible with system compliance to Level B.
23 50 μA
Interface Signals and Internal Protection
PARAMETER
Overvoltage Protection
Remote Sense
Overcurrent/Short Circuit
Protection
Master/Slave Operation
CONDITIONS/DESCRIPTION
Provided on 5 volt output units where indicated.
Other outputs may use optional overvoltage protectors OVP-12 and OVP-24.
Total voltage compensation for cable losses with respect to the main output.
Provided on models where indicated.
Automatic current limit/foldback. Rated as a percentage of output power.
MIN
NOM
MAX UNITS
5.8 6.6 V
250 mV
115 120 140
%
For parallel operation of up to 6 units. Master/slave pin provided on F case models only. Contact factory for application notes.
105553 Rev. AA
Page 5 of 9
www.power-one.com

5 Page










PáginasTotal 9 Páginas
PDF Descargar[ Datasheet HCAA-60W-AG.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
HCAA-60W-AGLinear Power SuppliesPower One
Power One

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar