150 Watts
SDS150www.DataSheet4U.com Series
xppower.com
3” x 5” Footprint
Fits 1U Applications
Convection-cooled
Open Frame & U-Channel Versions
Optional Power Fail Detect Signal
Optional Low Temperature Operation
Up to 90% Efficiency
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current
Input Protection
• 90-264 VAC (120-370 VDC)
• 47-63 Hz
• 2.0 A at 115 VAC
1.0 A at 230 VAC
• 20 A at 115 VAC
63 A at 230 VAC
• >0.95
• <0.40 mA at 115 VAC
<0.75 mA at 230 VAC
• 3.15 A on board fuse
Output
Output Voltage
• See table
Output Voltage Trim • ±5%
Initial Set Accuracy • ±1%
Minimum Load
• No minimum load required
Start Up Delay
• 2 s max
Start Up Rise Time
• 2 ms typical
Hold Up Time
• >16 ms
Line Regulation
• 1% max, ±0.5% typical
Load Regulation
• 5% max, ±3.0% typical
Transient Response
• 4% max deviation, recovery to within 1%
in 500 µs for a 50% load change
Ripple & Noise
• 1% pk-pk max
Overvoltage Protection • 112-132%, recycle input to reset
Overload Protection • 110-150% with auto recovery
Short Circuit Protection • Trip & restart (Hiccup mode),
auto recovery
Temperature
Coefficient
• 0.04%/°C
General
Efficiency
Isolation
Switching Frequency
Power Density
Signals
MTBF
• 88% typical, 90% max
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VDC Output to Ground
• PWM 60 kHz typical, PFC 100 kHz typical
• 6.9 W/In3 for open frame version
• Power Fail Detect = TTL low (option)
• >100 kHrs per MIL-HDBK-217F
Environmental
Operating Temperature • 0 °C to +70 °C, derate linearly from 100%
load at +50 °C to 50% load at +70 °C,
low temperature option ‘-L’ -40 °C
Cooling
• Convection-cooled
Operating Humidity • 5-95% RH, non-condensing
Storage Temperature • -40 °C to +85 °C
Vibration
• 2 g on 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
• EN55022, FCC Part 15, level B conducted
• EN61000-3-2
• EN61000-3-3
• EN61000-4-2, level 2 Perf Criteria A
• EN61000-4-3, 3 V/m Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, level 2 Perf Criteria A
• EN61000-4-11, 70% UT for 10 ms,
40% UT for 100 ms, <5% UT for 5000 ms
Perf Criteria A, B, B
• EN60950-1, UL60950-1, CSA60950-1
per cUL, CE Mark LVD

1 page





PáginasTotal 2 Páginas
PDF Descargar[ Datasheet SDS150.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
SDS150AC-DC Power SuppliesXP Power Limited
XP Power Limited
SDS152ASwitching DiodeAUK
AUK
SDS152AFSwitching DiodeAUK corp
AUK corp
SDS152KSwitching DiodeAUK
AUK

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar