DataSheet26.com

NFS110-7601J PDF даташит

Спецификация NFS110-7601J изготовлена ​​​​«Emerson» и имеет функцию, называемую «AC-DC / 86W - 135W».

Детали детали

Номер произв NFS110-7601J
Описание AC-DC / 86W - 135W
Производители Emerson
логотип Emerson логотип 

5 Pages
scroll

No Preview Available !

NFS110-7601J Даташит, Описание, Даташиты
Embedded Power for
Business-Critical Continuity
NFS110 Series
Single & quad output
Rev. 06.30.09_69
NFS110 Series
 of 5
Total Power: 80 - 110 W
Input Voltage: 85 - 264 Vac
120 - 370 Vdc
# of Outputs: Single, quad
Special Features
• 7.0 x 4.25 x 1.8 inch package
• Overvoltage and short circuit
protection
• 110 W with 20 CFM
• Adjustable outputs
• EN55022, EN55011 conducted
emissions level B
• UL, VDE and CSA safety
approvals
• CE mark
• Available RoHS compliant
• 2 year warranty
Safety
• VDE0805/EN60950/
• IEC950/IEC1010
File No. 10401-3336-0213
• Licence No. 4001467 7
• UL1950 File No. E132002
• CSA C22.2 No. 950
File No. LR41062C
Electrical Specifications
Output
Voltage adjustability:
Line regulation:
Overshoot/undershoot:
Temperature coefficient:
Overvoltage protection:
Output power limit:
Minimum output current:
Short circuit protection:
+5.1 V o/p on multi’s
5.1 V single output
12 V single output
15 V single output
24 V single output
LL to HL, FL
All outputs on all units
At turn-on
All outputs
Multi o/p 5.1 V only
5.1 V single output
12 V single output
15 V single output
24 V single output
Primary power limited
(See Note 13)
Burst mode operation
3.0%
3.0%
12 - 14 V
15 - 18 V
24 - 30 V
±0.1% max.
0%
±0.02%/°C
6.25 V ± 0.75 V
6.25 V ± 0.75 V
15.75 V ± 1.0 V
22 V ± 1.5 V
33 V ± 2.5 V
Pin max. 160 W
Pout min. 110 W
0A
Input
Input voltage range:
Input frequency range:
Input surge current:
230 Vac
85 - 264 Vac
120 - 370 Vdc
47 - 440 Hz
35 A
Safety ground leakage current: 110 Vac, 50 Hz
230 Vac, 50 Hz
0.2 mA, max.
0.4 mA, max.
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated









No Preview Available !

NFS110-7601J Даташит, Описание, Даташиты
Embedded Power for
Business-Critical Continuity
EMC Characteristics
Conducted emissions:
Radiated emissions:
ESD  air:
ESD contact:
Surge:
Fast transients:
Radiated immunity:
Conducted immunity:
General Specifications
Hold-up time:
Efficiency:
Isolation voltage:
Approvals and standards:
(see note 12)
Weight:
MTBF (@25 ºC):
EN55022, FCC part 15
EN55022, FCC part 15
EN61000-4-2, level 3
EN61000-4-2, level 4
EN61000-4-3, level 3
EN61000-4-4, level 3
EN61000-4-5, level 3
EN61000-4-6, level 3
Level B
Level A
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 2
Perf. criteria 1
110 Vac @ 80 W
110 Vac @ 110 W
230 Vac @ 80 W
230 Vac @ 100 W
35 ms
17 ms
140 ms
100 ms
Multiple outputs
+5.1 V single
12 V and 15 V singles
24 V single
70% typical
70% typical
72% typical
75% typical
Input/output
Input/chassis
3000 Vac
1500 Vac
VDE0805, EN60950, IEC950, IEC1010, UL1950, CSA C22.2 No. 950
Singles
Multiple outputs
MIL-HDBK-217E
550 g (19.4 oz)
600 g (21.2 oz)
125,000 hours min.
Rev. 06.30.09_69
NFS110 Series
 of 5
Environmental Specifications
Thermal performance:
Operating ambient
0° C to +70 °C
(See notes 9, 10)
Relative humidity:
Altitude:
Vibration:
(See Note 11)
Non-operating
-40 °C to +85 °C
0 °C to 50 °C convection cooled
80 W
+50 °C to +70 °C, convection cooled Derate 2 W/°C
0 °C to +50 °C, 20 CFM forced air
110 W
+50 °C to +70 °C, 20CFM forced air Derate 2.75 W/°C
Peak, 0 °C to +50 °C, max. 60 seconds 110W
Non-condensing
5 to 95% RH
Operating
10,000 feet max.
Non-operating
40,000 feet max.
5 - 500 Hz
2.4 G rms peak









No Preview Available !

NFS110-7601J Даташит, Описание, Даташиты
Embedded Power for
Business-Critical Continuity
Ordering Information
Output
Voltage
Max (1)
+5.1 V
+12 V
–12 V
–5 V
+5.1 V (IA)
+24 V (IB) (6)
+12 V
–12 V
+5.1 V
15 V
-15 V
-5 V
12 V
15 V
24 V
8A
4.5 A
0.5 A
0.5 A
8A
3.5 A
4.5 A
0.5 A
8A
4A
0.5 A
0.5 A
7A
5A
3.5 A
Output Currents
Peak (2)
20 A
9A
1.5 A
1.5 A
20 A
4.5 A
9A
1.5 A
20 A
7.5 A
1.5 A
1.5 A
9A
7.3 A
4.5 A
Fan (3)
10 A
5A
1A
1A
10 A
4.5 A
5A
1A
10 A
5A
1A
1A
9A
7.3 A
4.5 A
Rev. 06.30.09_69
NFS110 Series
 of 5
Ripple (4)
50 mV
120 mV
120 mV
50 mV
50 mV
240 mV
120 mV
120 mV
50 mV
150 mV
150 mV
50 mV
120 mV
150 mV
240 mV
Total
Regulation (5)
± 2.0%
± 3.0%
± 3.0%
± 3.0%
± 2.0%
+10/–5.0%
± 3.0%
± 3.0%
± 2.0%
± 4.0%
± 3.0%
± 3.0%
± 2.0%
± 2.0%
± 2.0%
Mo�d�e��l �N�u�m�b�e��r�s� (13, 14, F)
NFS110-7601PJ
NFS110-7602PJ (6)
NFS110-7604PJ
NFS110-7612J (7,8)
NFS110-7615J (7,8)
NFS110-7624J (7,8)
Notes
1 Convection cooled, 80 W maximum.
2 Peak outputs lasting less than 60 seconds with duty cycle less than 10%. Total
peak power must not exceed 110 W.
3 Forced air, 20 CFM at 1 atmosphere, 110 W maximum.
4 Figure is peak-to-peak. Output ripple is measured across a 50 MHz bandwidth
using a 12 inch twisted pair terminated with a 47 µF capacitor.
5 Total regulation is defined as the static output regulation at 25 °C, including
initial tolerance, line voltage within stated limits and output voltages adjusted
to their factory settings.
6 To achieve stated regulation on the 24 V output on the NFS110-7602PJ, the
following load condition must be true: IA / IB ≤ 5, where:
IA = +5.1 V output current, and
TIBh=e
+24
+24
V
V
output
output
current
will maintain
±5.0%
regulation
under
the
following
additional condition: IA ≤ 5 A.
7 Single output models have floating outputs which may be referenced as
either positive or negative. Higher voltage supplies may be adjusted over a
wide output voltage range, as long as the total output power does not exceed
80 Watts (natural convection) or 110 Watts (forced air).
8 Power fail detect not available on single output models.
9 Derating curve is application specific for ambient temperatures >50 °C,
for optimum reliability no part of the heatsink should exceed 90 ºC and no
semiconductor case temperature should exceed 100 ºC.
10 Caution: Allow a minimum of 1 second after disconnecting the power when
making thermal measurements.
11 Three orthogonal axes, random vibration, 10 minute test for each axis.
12 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
13 Artesyn Technologies recommends a minimum load of 11 W to achieve the
design MTBF. See the derating curve on page 3.
14 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
15 NOTICE: Some models do not support all options. Please contact your
local Emerson Network Power representative or use the on-line model
number search tool at http://www.PowerConversion.com to find a suitable
alternative.
Transient Response
NFS110-7601PJ +5.1 V (7.5 A to 10 A)
+12 V (2.5 A to 5 A)
-12 V (0.5 A to 1 A)
-5 V (0.5 A to 1 A)
NFS110-7602PJ
NFS110-7604PJ
+5.1 V (7.5 A to 10 A)
+24 V (1.5 A to 3 A)
+12 V (2.5 A to 5 A)
-12 V (0.5 A to 1 A)
+5.1 V (7.5 A to 10 A)
+15 V (2.5 A to 5 A)
-15 V (0.5 A to 1 A)
-5 V (0.5 A to 1 A)
NFS110-7605J
NFS110-7612J:
NFS110-7615J
NFS110-7624J
+5.1 V (10 A to 20 A)
+12 V (4.5 A to 9 A)
+15 V (3.65 A to 7.3 A)
+24 V (2.25 A to 4.5 A)
150 mV peak, 1 ms recovery
100 mV peak, 0.5 ms recovery
100 mV peak, 0.5 ms recovery
100 mV peak, 0.5 ms recovery
150 mV peak, 1 ms recovery
300 mV peak, 1 ms recovery
100 mV peak, 0.5 ms recovery
100 mV peak, 0.5 ms recovery
150 mV peak, 1 ms recovery
100 mV peak, 0.5 ms recovery
100 mV peak, 0.5 ms recovery
100 mV peak, 0.5 ms recovery
250 mV peak, 1 ms recovery
360 mV peak, 1 ms recovery
450 mV peak, 1 ms recovery
720 mV peak, 1 ms recovery










Скачать PDF:

[ NFS110-7601J.PDF Даташит ]

Номер в каталогеОписаниеПроизводители
NFS110-7601JAC-DC / 86W - 135WEmerson
Emerson
NFS110-7601PJAC-DC / 86W - 135WEmerson
Emerson

Номер в каталоге Описание Производители
TL431

100 мА, регулируемый прецизионный шунтирующий регулятор

Unisonic Technologies
Unisonic Technologies
IRF840

8 А, 500 В, N-канальный МОП-транзистор

Vishay
Vishay
LM317

Линейный стабилизатор напряжения, 1,5 А

STMicroelectronics
STMicroelectronics

DataSheet26.com    |    2020    |

  Контакты    |    Поиск