DataSheet26.com

NEA010 PDF даташит

Спецификация NEA010 изготовлена ​​​​«Murata Manufacturing» и имеет функцию, называемую «Non-Isolated 10A SIP DC/DC Converters».

Детали детали

Номер произв NEA010
Описание Non-Isolated 10A SIP DC/DC Converters
Производители Murata Manufacturing
логотип Murata Manufacturing логотип 

18 Pages
scroll

No Preview Available !

NEA010 Даташит, Описание, Даташиты
Volant NEA/NEF0ww1w.D0ataShSeet4eU.cromies
Non-Isolated 10A SIP DC/DC Converters
Features:
9 Small size, minimal footprint/low profile
9 10A Output Current (all voltages)
9 High Efficiency: up to 95%
9 High reliability
9 RoHS Compliant
9 Cost efficient open frame design
9 Pre-bias monotonic start-up
9 +ve Enable Logic and –ve Enable Logic models available
Output
Vout
(V)
Iout
(A)
1.0 10
1.2 10
1.5 10
1.8 10
2.0 10
2.5 10
3.3 10
5.0 10
PARD
(mVp-p)
Regulation
Max
Typ.
30
30
30
30
30
30
30
30
Max.
50
50
50
50
50
50
50
50
Line
+/-0.2%
+/-0.2%
+/-0.2%
+/-0.2%
+/-0.2%
+/-0.2%
+/-0.2%
+/-0.2%
Load
+/-0.5%
+/-0.5%
+/-0.5%
+/-0.5%
+/-0.5%
+/-0.5%
+/-0.5%
+/-0.5%
Input
Vin
Nom.
(V)
Range
(V)
12 8.3 – 14
12 8.3 – 14
12 8.3 – 14
12 8.3 – 14
12 8.3 – 14
12 8.3 – 14
12 8.3 – 14
12 8.3 – 14
Iin
TYP
(A)
0.992
1.163
1.404
1.666
1.832
2.264
2.956
4.385
Efficiency
Full Load
Typ.
84%
86%
89%
90%
91%
92%
93%
95%
Technical enquiries email: [email protected], tel: +508 339 3000
1 NEA/NEF10_6200850000_B01_21/04/08









No Preview Available !

NEA010 Даташит, Описание, Даташиты
Murata Power Solutions Volant NEA/NEF0ww1w.D0ataShSeet4eU.cromies
Non-Isolated 10A SIP DC/DC Converters
Input Characteristics
Input Voltage Operating Range
Input Reflected Ripple Current
Inrush Current Transient
Input Filter Type (external)
Input Turn ON Threshold
Input Turn OFF Threshold
ON Control
OFF Control
Notes & Conditions
Low ESR
Open Circuit or =Vin
<0.4VDC
Output Characteristics
Vout Accuracy
Output Loading
Output Ripple & Noise
@ 20Mhz Bandwidth.
Maximum Capacitive Load
Vout Trim Range
Total Accuracy
Current Limit
Output Line Regulation
Output Load Regulation
Turn-on Overshoot
SC Protection Technique
Pre-bias Start-up at output
Notes & Conditions
100% load
Low ESR
Over line/load temperature
Hiccup with auto recovery
Unit starts monotonically with pre-
bias
Dynamic Characteristics
Load Transient
Frequency
Rise Time
Start-Up Time
Notes & Conditions
50% step, 0.1A/μs
Settling Time
10% Vo to 90% Vo
Vin to Vout and On/Off to Vout
Vout rise to monotonic
General Specifications
MTBF
Thermal Protection
Operating Temperature
Operating Ambient Temperature
Dimensions
Pin Dimensions
Pin Material
Weight
Flammability Rating
Notes & Conditions
Calculated (MIL-HDBK-217F)
Hotspot
Without derating 100LFM
See Power derating curve
2”Lx0.327”Wx0.512”H
(50.8x8.3x13.0mm)
0.025” (0.64mm) SQUARE
Matte Sn Finish on component
Leads
UL94V-0
Standards Compliance
CSA C22.2, No.60950/UL 60950, Third Edition (2000), File UL E165113
Min Typ. Max
8.3 12 14
200
0.2
100
8.5
8.0
Units
Vdc
mA p-p
A2s
μF
V
V
Min Typ. Max
-1.5 +1.5
0 10
50
-10
-0.2
+0.5
<2%
17
8000
+10
+0.2
-0.5
1
Units
%
A
MVp-p
μF
%
A
%
%
%
Min Typ. Max
100
200
300
3.5
7
Units
mV
μs
KHz
ms
ms
Min Typ. Max Units
1.0 x106 Hrs
110 °C
-40 60 °C
-40 85 °C
0.64
mm
10 g
2 NEA/NEF10_6200850000_B01_21/04/08









No Preview Available !

NEA010 Даташит, Описание, Даташиты
Murata Power Solutions Volant NEA/NEF0ww1w.D0ataShSeet4eU.cromies
Non-Isolated 10A SIP DC/DC Converters
Thermal Considerations
The power module operates in a variety of thermal environments; however, sufficient cooling
should be provided to help ensure reliable operation of the unit. Heat is removed by
conduction, convection, and radiation to the surrounding environment. The thermal data
presented is based on measurements taken in a set-up as shown in fig 1. when the airflow is
parallel to the long axis of the module. The de-rating applies accordingly.
The temperature at either location should not exceed 110 °C. The output power of the module
should not exceed the rated power for the module (VO, set x IO, max).
Figure 1: Thermal Measurement Setup
Convection Requirements for Cooling
To predict the approximate cooling needed for the module, refer to the Power Derating Curve in
Figure 2 to Figure 9.
These derating curve are approximations of the ambient temperature and airflow required to keep the
power module temperature below it's maximum rating. Once the module is assembled in the actual
system, the module's temperature should be verified.
Proper cooling can be verified by measuring the power module's temperature at Q1-pin 6 and Q2-pin
6 as shown in Figure 1.
3 NEA/NEF10_6200850000_B01_21/04/08










Скачать PDF:

[ NEA010.PDF Даташит ]

Номер в каталогеОписаниеПроизводители
NEA010Non-Isolated 10A SIP DC/DC ConvertersMurata Manufacturing
Murata Manufacturing
NEA016Non-Isolated 16A SIP/SMT DC/DC ConvertersMurata
Murata

Номер в каталоге Описание Производители
TL431

100 мА, регулируемый прецизионный шунтирующий регулятор

Unisonic Technologies
Unisonic Technologies
IRF840

8 А, 500 В, N-канальный МОП-транзистор

Vishay
Vishay
LM317

Линейный стабилизатор напряжения, 1,5 А

STMicroelectronics
STMicroelectronics

DataSheet26.com    |    2020    |

  Контакты    |    Поиск