Número de pieza | H5S | |
Descripción | Digital Time Switch | |
Fabricantes | Omron | |
Logotipo | ||
Hay una vista previa y un enlace de descarga de H5S (archivo pdf) en la parte inferior de esta página. Total 27 Páginas | ||
No Preview Available ! Digital Time Switch
H5S
Easier, More Convenient Time Switches, with
New 4-circuit Output and Yearly Models in
Addition to 2-circuit Weekly Models
• Independent Day Keys provide easier operation.
• Temporary holiday setting function makes it easy to turn OFF
output for holidays and non-operating days.
• Settings can be made even with the Time Switch turned OFF.
• Test mode enables easy program checking.
• Complies with EMC Directives, UL/CSA, and other safety
standards.
• Includes summer time (DST) adjustment.
Yearly models also offer automatic switching to DST.
• Set value can be changed both upward and downward for
speedier setting.
• Integrated temperature compensation circuit helps keep
accurate time over a wide temperature range. (See note 1.)
• Includes time counter and total counter functions with alarm
indicator. (See note 2.)
• Bank function allows program switching by an external input.
(See note 3.)
• New 4-circuit output models with a compact, 72 × 72-mm DIN
size added to the series.
Note: 1. Available only on yearly models.
2. Available only on 2-circuit models.
3. Available only on weekly models.
www.DataSheet4U.com
CSM_H5S_DS_E_4_1
Features
Easier and More Convenient to Use
■ Simple Setting
Independent Day Keys make setting easy.
Up/down set value changing
for speedy setting.
Temporary holidays
(non-operating days)
are also easy to set.
Weekly models: Specify the day.
Yearly models: Specify the date.
■ Convenient Functions
Time Counter/Total Counter Functions (See note.)
This function makes it possible to monitor the total time that a load
has been applied, or the total number of operating cycles. It allows
the Time Switch to be used for managing maintenance.
Time Adjustment Function (See note.)
The time can be set to 00 min 00 s by using an external input. The
times on multiple Time Switches can also be easily synchronized.
Synchronized!
Master
Slave
Note: Equipped on 2-circuit models.
Slave
With alarm indicator
Shows total lamp ON time
1
1 page ■ Operation
H5S
www.
Item
Weekly 2-circuit Models
(H5S-W@2)
Yearly 2-circuit Models
(H5S-Y@2)
Yearly 4-circuit Models
(H5S-Y@4)
Operation method
Digital quartz
Operation period
1 week (7 days)
1 year (with integrated calendar to 2099)
Display
• Day, hrs (switchable between 24-hr indication and a.m./p.m. 12-hr indication), minutes, seconds
(0.00 to 23:59, 0.00 to 11:59 a.m., 0.00 to 11:59 p.m.)
• Digital indication by LCD (character height: 10 mm)
• Digital display of operation schedule during operation
• Timing chart display of operation schedule during operation
Min. setting unit
1 min
Number of Weekly program 40 steps/circuit
steps that (See note 1.)
can be set
48 steps/circuit (See note 2.)
24 steps/circuit (per season) (See
note 3.)
48 steps/circuit (See note 2.)
12 steps/circuit (per season) (See
note 3.)
Yearly program ---
4 yearly programs/circuit
Number of
---
settable yearly
temporary
holiday settings
16
Note: 1. Depending the operation, the following steps can be used for weekly programs.
Timer operation: 2 steps
Pulse-output operation: 1 step
Cyclic operation: 4 steps
2. When the season switching setting is not being used.
3. When the season switching setting is being used.
D
■ Operation Functions
Item
Weekly timer
operation
Weekly pulse-
output
operation
Weekly 2-circuit Models (H5S-W@2) Yearly 2-circuit Models (H5S-Y@2)
Yearly 4-circuit Models (H5S-Y@4)
Timer operation
Controls the output according to the set time of ON and OFF.
• Min. setting unit: 1 min
ON OFF
• Multiple-day operation also possible.
Pulse output operation
Pulse width
ON
Output turns ON for a fixed period (pulse width) at the set ON time.
• Pulse width: 1 to 59 s (in 1-s increments), or 1 to 60 min (in 1-min increments)
• The pulse width can be set for each step.
Weekly cyclic
operation
Cyclic operation
OFF
Repeatedly turns ON and OFF during the period from the cyclic start time to the stop time.
Independent ON- and OFF-time settings are possible.
• Min. setting unit: 1 min
Start ON Stop
( )The timer operation repeatedly turns the signal ON and OFF for the time widths specified
by the ON time and OFF time during the period from the day of the week and time that are
set for the cyclic start time to the day of the week and time that are set for the stop time.
Yearly timer
operation
---
Adds a yearly timer operation to the weekly timer program.
For details, refer to About Yearly Programs on page 18.
Yearly pulse-
output
operation
---
Adds a yearly pulse-output operation to the weekly pulse-output program.
For details, refer to About Yearly Programs on page 18.
Temporary
Sets temporary holidays (non-operating days) without having to revise the existing program.
holiday setting For details, refer to Setting Temporary Holidays (Weekly) and Setting Temporary Holidays (Yearly) on page 20.
Day override
operation
Executes the operation for one day
---
temporarily on another day in the 7-day
period starting from the current day.
For details, refer to Day Override
Operation on page 21.
Program check Consecutively displays the days and times when the output is set to turn ON and OFF over the course of one week in the
sequence in which the Time Switch is to operate.
For details, refer to Program Check Function on page 21.
5
5 Page ■ Accessories (Order Separately)
Protective Cover
Y92A-72C
DIN Track Mounting
Base
Y92F-90
H5S
www.DataSheet4U.com
Large Terminal Covers
Y92A-72H (two per set)
Note: The DIN Track Mounting Base can be
used only with the surface mounting
models (H5S-@FA@/-@FB@).
Note: The Large Terminal Cover can be
used only with the surface mounting
models (H5S-@FA@/-@FB@).
■ Track Mounting Accessories (Order Separately)
Mounting Track
PFP-100N
PFP-50N
PFP-100N2
7.3±0.15
4.5 4.5
35±0.3
27±0.15
15 25
25
10
25 25
10
1,000 (500) *
15 (5) *
1
* The numbers in parentheses ( ) are dimensions for the PFP-50N
15 25
25
10
1,000
End Plate
PFP-M
M4 × 8
pan-head
screw
50
11.5
10
6.2
1.8
1
35.5 35.3
1.8
10
M4 spring washer
1.3
4.8
Spacer
PFP-S
25 25 15
10
5
16
35±0.3 27 24
1
29.2
1.5
16
12
34.8
44.3
16.5
11
11 Page |
Páginas | Total 27 Páginas | |
PDF Descargar | [ Datasheet H5S.PDF ] |
Número de pieza | Descripción | Fabricantes |
H5004 | LAN DISCRETE TRANSFORMER MODULES | PULSE |
H5004NL | 1000BASE-T Magnetics Module | PULSE |
H5007 | LAN DISCRETE TRANSFORMER MODULES | PULSE |
H5007NL | 1000BASE-T Magnetics Module | PULSE |
Número de pieza | Descripción | Fabricantes |
SLA6805M | High Voltage 3 phase Motor Driver IC. |
Sanken |
SDC1742 | 12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters. |
Analog Devices |
DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares, |
DataSheet.es | 2020 | Privacy Policy | Contacto | Buscar |