DataSheet26.com

W28-XQ1A-6 PDF даташит

Спецификация W28-XQ1A-6 изготовлена ​​​​«Tyco Electronics» и имеет функцию, называемую «Switchable or Push to Reset Fuseholder-Type Thermal Circuit Breaker».

Детали детали

Номер произв W28-XQ1A-6
Описание Switchable or Push to Reset Fuseholder-Type Thermal Circuit Breaker
Производители Tyco Electronics
логотип Tyco Electronics логотип 

2 Pages
scroll

No Preview Available !

W28-XQ1A-6 Даташит, Описание, Даташиты
www.DataSheet.co.kr
Catalog 1308242
Issued 3-03 (PDF Rev. 4-04)
P&B
W28 series
Switch/Breaker
(Consult factory for availability)
Push-to-Reset Breaker
Switchable or
Push to Reset
Fuseholder-Type
Thermal Circuit Breaker
Note: VDE, Demko, Semko not available on 16A and 20A W28 only.
Features
• Switchable version combines on-off switch and circuit protection in a
single unit.
• Approved to many international standards (push to reset type).
• Replaces slow blow glass cartridge fuse.
• Labor-saving snap-in mounting.
• Button extends for visual trip indication on push to reset model.
• Rocker on switchable model moves to “overload” position upon trip.
Agency Approvals
W28 series is UL 1077 Recognized as Supplementary Protectors, File
E69543, and CSA Certified as Appliance Component Protectors, File
LR15734. W28 breakers have been issued Certificate of Suitability
CS2190N as supplementary Equipment Protectors by the Energy
Authority of New South Wales, Australia. W28 breakers are also
DEMKO (Denmark) and SEV (Switzerland) approved. VDE approved
for use in office equipment and provides 8mm isolation. 16 amp and
20 amp models do not have VDE, DEMKO and SEV approvals at
present. W28-S is UL 1077 Recognized, and CSA Certified for models
up to and including 15 amps.
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Electrical Data @ 25°C
Calibration: Will continuously carry 100% of rating.
3-20 amp models – may trip between 101% and 134%, but
must trip at 135% of rating within one hour at +25°C.
0.25-2 amp models – may trip between 101% and 174%, but
must trip at 175% of rating within one hour at +25°C.
Dielectric Strength: Over 1,500 volts RMS.
Maximum Operating Voltages: 32VDC; 250VAC, 50/60 Hz.
Interrupt Capacity: 1,000 amps at 250VAC, 50/60 Hz. and 32VDC in
accordance with UL standard 1077.
Resettable Overload Capacity: Six times rated current for 0.25 through 2
amp models. Ten times rated current for
3 through 20 amp models.
Reset Time: 180 seconds max. for 0.25 through 2 amp models. 10 to 60
seconds for 3 through 20 amp models.
Typical Resistance vs. Current Rating @ +25°C
Current
Rating
in Amps
0.25
0.50
0.75
1.0
2.0
3.0
4.0
5.0
6.0
7.0
Typical
Resistance
in Ohms
14.0
3.55
2.0
0.89
0.17
0.069
0.043
0.030
0.026
0.017
Current
Rating
in Amps
8.0
9.0
10.0
11.0
12.0
13.0
14.0
15.0
16.0
20.0
Typical
Resistance
in Ohms
0.016
0.014
0.011
0.01
0.009
0.009
0.007
0.007
0.007
0.006
Mechanical/Environmental Data
Endurance Cycling(switchable type): Typically 30,000 operations at
100% of rating.
Termination: .250” (6.35mm) quick connects. Soldering to terminals is
not recommended.
Mounting: Snaps into panel from front. See Recommended Panel Cutouts.
Approximate Weight: 0.35 oz. (10g).
Time vs. Current Trip Curve @ +25°C
1000
900
;;;800
700
(A)
600
500
400
;300
(A) All 3-20 Amp Models
Overload Trip Times
100%
135%
200%
400%
600%
800%
1000%
No Trip
Trip in 1 hour
2.2-15.0 Sec.
0.55-1.8 Sec.
0.27-0.7 Sec.
0.17-0.45 Sec.
0.12-0.3 Sec.
(B) All 0.25-2 Amp Models
Overload Trip Times
100%
175%
200%
400%
600%
No Trip
Trip in 1 hour
4.5-28.0 Sec.
1.0-6.5 Sec.
0.4-4.0 Sec.
(B)
Ambient Compensation Chart
1.40
1.30
1.20
1.10
1.00
0.90
0.80
0.70
0.60
20 10 0 10 20 30 40 50 60
Ambient Temperature In Degrees Centigrade (°C)
200
175
135
100
To use this chart: Read up from the ambient
temperature to the curve, and across to find a
0 correction factor. Multiply the breaker rating by the
.1
1
10
100
1000
correction factor to determine the compensated
rating. Calculate the overloads in terms of the
Time In Seconds
compensated rating to use the published trip curve.
Do not use these devices outside their specified
operating temperature ranges.
Dimensions are shown for
110 reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Datasheet pdf - http://www.DataSheet4U.net/









No Preview Available !

W28-XQ1A-6 Даташит, Описание, Даташиты
www.DataSheet.co.kr
Ordering Information
Catalog 1308242
Issued 3-03 (PDF Rev. 4-04)
B WTypical Part Number
28
-X
Q
1. Designator:
W = Circuit breaker
2. Series Number:
28 = Single Pole Fuseholder Type
3. Circuit Function:
X = Series Trip, Push-to-Reset Button S = Series Trip, Switchable Rocker (consult factory for "S" availability)
4. Terminal Type and Mounting:
Q = .250(6.35mm) Quick Connect will mount in .032-.062(.813mm 1.574mm) thick panel.
T = .250(6.35mm) Quick Connect will mount in .075-.105(1.905mm 2.667mm) thick panel.
For panel thicknesses other than above, order Qtype and 55-025B Internal Tooth Push-On Lockwasher.
5. Bezel Color:
1 = Black with White Rate Marking 11 = Black with No Rate Marking
2 = Red with Black Rate Marking 21 = Red with No Rate Marking
B = Black with White ResetMarked On Bezel (No Rate Marking)
Not available with Circuit Function S.
Consult factory for other bezel colors.
6. Button Color:
A = Black
B = Red
Consult factory for other button colors.
7. Amp Rating:
0.2514 7 10 13 16
0.5025 8 11 14 20*
0.753
6 9 12 15
Not available with Circuit Function S.
* Contact factory for availability.
P&B
1 A -5
Stock Items Authorized distributors are more likely to stock the following items.
W28-XQ1A-0.25
W28-XQ1A-0.50
W28-XQ1A-0.75
W28-XQ1A-1
W28-XQ1A-2
W28-XQ1A-3
W28-XQ1A-4
W28-XQ1A-5
W28-XQ1A-6
W28-XQ1A-7
W28-XQ1A-8
W28-XQ1A-10
W28-XQ1A-12
W28-XQ1A-15
W28-XQ1A-20
W28-XT1A-10
W28-XT1A-12
Outline Dimensions
Push-to-Reset Type
1.535 MAX.
(38.99)
.54 MAX.
(13.716)
.37
(9.4)
.625 MAX.
(15.875)
.325 MAX.
(8.26)
.19
(4.83)
.76 MAX.
(19.31)
I
O
.76 MAX.
(19.31)
AMP RATING
Switchable Type
ROCKER POSITION
DURING OVERLOAD
(TRIP) CONDITION
I
O
AMP RATING
.250 x .032 (6.35 x .813)
QUICK CONNECT TERMINALS
Recommended Panel Cutouts
.970 DIA.
(25.64)
55-025B
INTERNAL TOOTH
PUSH-ON LOCKWASHER
For panels greater than .105(2.67) thickness
.570-.575
(14.478-14.605)
.540-.550
(13.716-13.970)
.625-.635
(15.875-16.129)
.625-.635
(15.875-16.129)
.625-.635
(15.875-16.129)
Note:
1. Soldering to terminals is not recommended.
2. Recommended Panel Thickness: Style Q: .032- .062(.813 mm - 1.574 mm)
Style T: .075- .105(1.905 mm - 2.667 mm)
3. Internal tooth push-on washer available for panel thickness not covered above. Part
No. 55-025B.
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
111
Refer to inside back cover. Datasheetpdf-http://www.DataSheet4U.net/










Скачать PDF:

[ W28-XQ1A-6.PDF Даташит ]

Номер в каталогеОписаниеПроизводители
W28-XQ1A-0.25Switchable or Push to Reset Fuseholder-Type Thermal Circuit BreakerTyco Electronics
Tyco Electronics
W28-XQ1A-0.50Switchable or Push to Reset Fuseholder-Type Thermal Circuit BreakerTyco Electronics
Tyco Electronics
W28-XQ1A-0.75Switchable or Push to Reset Fuseholder-Type Thermal Circuit BreakerTyco Electronics
Tyco Electronics
W28-XQ1A-1Switchable or Push to Reset Fuseholder-Type Thermal Circuit BreakerTyco Electronics
Tyco Electronics

Номер в каталоге Описание Производители
TL431

100 мА, регулируемый прецизионный шунтирующий регулятор

Unisonic Technologies
Unisonic Technologies
IRF840

8 А, 500 В, N-канальный МОП-транзистор

Vishay
Vishay
LM317

Линейный стабилизатор напряжения, 1,5 А

STMicroelectronics
STMicroelectronics

DataSheet26.com    |    2020    |

  Контакты    |    Поиск