DataSheet26.com

NTA1209MC PDF даташит

Спецификация NTA1209MC изготовлена ​​​​«Murata» и имеет функцию, называемую «Isolated 1W Dual Output SM DC/DC Converters».

Детали детали

Номер произв NTA1209MC
Описание Isolated 1W Dual Output SM DC/DC Converters
Производители Murata
логотип Murata логотип 

4 Pages
scroll

No Preview Available !

NTA1209MC Даташит, Описание, Даташиты
NTA Series
Isolated 1W Dual Output SM DC/DC Converters
FEATURES
RoHS compliant
Efficiency up to 78%
Wide temperature performance at full
1 Watt load, –40°C to 85°C
UL 94V-0 Package material
Footprint over pins 1.64cm2
Lead frame technology
3.3V, 5V & 12V Input
3.3V, 5V, 9V, 12V & 15V Output
Internal SMD construction
Toroidal magnetics
1kVDC Isolation
MTTF up to 2.1 Million hours
Power density 1.36W/cm3
No heatsink required
Custom solutions available
Multi-layer ceramic capacitors
PRODUCT OVERVIEW
The NTA series of miniature surface mounted
DC/DC Converters employ leadframe
technology and transfer moulding techniques
to bring all of the benefits of IC style
packaging to hybrid circuitry. Co-planarity of the
lead positions is based upon IEC 191-6:1990. The
devices are suitable for all applications where
high volume production is envisaged.
For full details go to
www.murata-ps.com/rohs
SELECTION GUIDE
Order Code1
Nominal
Input
Voltage
Output
Voltage
Output
Current
Input
Current at
Rated Load
Efficiency
Isolation
Capacitance
MTTF2
V V mA mA % pF kHrs
NTA0303MC 3.3 ±3.3 ±152 402 75 29 1005
NTA0305MC
3.3
±5 ±100
388
78
30 399
NTA0309MC
3.3
±9 ±55
405
75
34 827
NTA0312MC 3.3 ±12 ±42
390
77
40 375
NTA0315MC 3.3 ±15 ±33
392
77
42 206
NTA0503MC
5
±3.3 ±152
259
77
31 964
NTA0505MC
5
±5 ±100
290
69 33 1697
NTA0505MEC
5
±5 ±100
251
80 42 367
NTA0509MC
5
±9 ±55
267
75 38 682
NTA0512MC
5
±12 ±42
260
77
44 343
NTA0515MC
5
±15 ±33
256
78
43 188
NTA1205MC
12
±5 ±100
121
69
50 559
NTA1209MC
12
±9 ±55
113
74
72 375
NTA1212MC 12 ±12 ±42 111 75 89 243
NTA1215MC 12 ±15 ±33 110
76 100 154
When operated with additional external load capacitance the rise time of the input voltage will determine the maximum external
capacitance value for guaranteed start up. The slower the rise time of the input voltage the greater the maximum value of the
additional external capacitance for reliable start up.
INPUT CHARACTERISTICS
Parameter
Conditions
Continuous operation, 3V input types
Voltage range
Continuous operation, 5V input types
Continuous operation, 12V input types
Reflected ripple current
Min. Typ. Max. Units
2.97 3.3 3.63
4.5 5 5.5 V
10.8 12 13.2
41 50 mA p-p
ISOLATION CHARACTERISTICS
Parameter
Conditions
Isolation voltage
Flash tested for 1 second
Resistance
Viso= 1000VDC
Min. Typ. Max. Units
1000 VDC
10 GΩ
GENERAL CHARACTERISTICS
Parameter
Conditions
0312MC, 0315MC
Switching frequency
0303MC, 0305MC, 0503MC, 0505MEC
All other variants
Min. Typ. Max. Units
100
110 kHz
115
ABSOLUTE MAXIMUM RATINGS
Short-circuit protection3
Lead temperature 1.5mm from case for 10 seconds
Internal power dissipation
Input voltage VIN, NTA03 types
Input voltage VIN, NTA05 types
Input voltage VIN, NTA12 types
1 second
300°C
700mW
5.5V
7V
15V
1. If components are required in tape and reel format suffix order code code with -R, e.g. NTA0505MC-R.
2. Calculated using MIL-HDBK-217F with nominal input voltage at full load.
3. Supply voltage must be disconnected at the end of the short circuit duration.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
www.murata-ps.com
Technical enquiries - email: [email protected], tel: +44 (0)1908 615232
KDC_NTA.G04 Page 1 of 4
Free Datasheet http://www.datasheet4u.com/









No Preview Available !

NTA1209MC Даташит, Описание, Даташиты
NTA Series
Isolated 1W Dual Output SM DC/DC Converters
OUTPUT CHARACTERISTICS
Parameter
Rated Power
Voltage Set Point Accuracy
Line regulation
Load Regulation1
Ripple and Noise
Conditions
TA=-40°C to 85°C
See tolerance envelope
High VIN to low VIN
10% load to rated load, 0303MC & 0503MC
10% load to rated load, 5V output types
10% load to rated load, 0309MC
10% load to rated load, 0509MC & 1209MC
10% load to rated load, 0312MC & 0315MC
10% load to rated load, 0512MC & 1212MC
10% load to rated load, 0515MC & 1215MC
BW=DC to 20MHz, 3.3V output types, NTA0305MC & NTA0505MEC
BW=DC to 20MHz, all other 5V output types
BW=DC to 20MHz, 9V output types
BW=DC to 20MHz, 12V output types
BW=DC to 20MHz, 15V output types
Min. Typ. Max. Units
1.0 W
1.0 1.2 %/%
10 15
10 12
9.0 10
6.5 8.0
%
11 14
6.0 8.5
6.0 7.0
40 80
50 100
35 80 mV p-p
50 110
65 110
TEMPERATURE CHARACTERISTICS
Parameter
Conditions
Specification
All output types
Storage
0305MC, 0505MEC, 0312MC, 0315MC
Case temperature rise above
0303MC, 0309MC, 0503MC
ambient
0505MC, 1205MC
All other variants
Cooling
Free air convection
Min. Typ. Max. Units
-40 85
-55 125
19
°C
25
46
35
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions NTA series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
For a part holding no specific agency approvals, such as the NTA series, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or
60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part
could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must
be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to
safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,
construction and environment. The NTA series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While
parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically
polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We
therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage.
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
TEMPERATURE DERATING GRAPH
1.5
1.0 85°C
0.5 Safe Operating Area
0
-40 0 50 100 150
Ambient Temperature (°C)
RoHS COMPLIANCE INFORMATION
This series is compatible with RoHS soldering systems with
a peak reflow solder temperature of 245ºC and time above
liquidus of 217ºC for 80 seconds. The pin termination finish
on this product series is Gold, plating thickness 0.1 microns
minimum. The series is backward compatible with Sn/Pb
soldering systems.
For further information, please visit www.murata-ps.com/rohs
1. 12V input types have typically 3% less load regulation change.
www.murata-ps.com
Technical enquiries - email: [email protected], tel: +44 (0)1908 615232
KDC_NTA.G04 Page 2 of 4
Free Datasheet http://www.datasheet4u.com/









No Preview Available !

NTA1209MC Даташит, Описание, Даташиты
TOLERANCE ENVELOPES
Tolerance Envelope - 3.3V output types.
+9%
+1%
V
NOM
-7%
Typical Load Line
+1%
-7%
-15%
10 25 50 75 100
Output Load Current (%)
NTA Series
Isolated 1W Dual Output SM DC/DC Converters
All other types.
+10%
+5%
V
NOM
Typical Load Line
+2.5%
-2.5%
-7.5%
10 25 50 75 100
Output Load Current (%)
PACKAGE SPECIFICATIONS
MECHANICAL DIMENSIONS
0.600 (15.24)
0.400 (10.16)
0.441
0.409
(11.20)
(10.40)
0.303
(7.70)
18 16 14 12 10
NTA0505MC
XYYWW
13 57 9
0.100(2.54)
0.026(0.65)
0.022(0.55)
0.059(1.50)
0.047(1.20)
10 PINS
0.008(0.2)
REFERENCE
PLANE
P
S
0.020(0.5)
±5.00°
0.260 (6.6) 0.250 (6.35)
0.234 (5.95) 0.230 (5.85)
0.11 (2.79) MAX
0.083
(2.10)
0.010 (0.25)
0.004 (0.10)
10 PINS
0.004 (0.1) S
All dimensions in inches ±0.01 (mm ±0.25mm). All pins on a 0.1 (2.54) pitch.
RECOMMENDED FOOTPRINT DETAILS




DETAIL A
S SEATING PLANE
0.074
(1.875) MAX
0.012 (0.30)
0.008 (0.20)
Weight: 1.53g
TUBE OUTLINE DIMENSIONS
œ œ
PIN CONNECTIONS
Pin Function
1 -VIN
3 +VIN
5 NA
7 OV
9 -VOUT
10 NA
12 +VOUT
14 NA
16 NA
18 NA
NA - Not available for electrical connection.
 


 
 
 
  .*/
 
Unless otherwise stated all dimensions in inches ±0.02 (mm±0.5).
Tube length : 18.70±0.07 (475±2.0).
Tube Quantity : 25
www.murata-ps.com
Technical enquiries - email: [email protected], tel: +44 (0)1908 615232
KDC_NTA.G04 Page 3 of 4
Free Datasheet http://www.datasheet4u.com/










Скачать PDF:

[ NTA1209MC.PDF Даташит ]

Номер в каталогеОписаниеПроизводители
NTA1209MIsolated 1W Dual Output SM DC-DC ConvertersC&D Technologies
C&D Technologies
NTA1209MCIsolated 1W Dual Output SM DC/DC ConvertersMurata
Murata

Номер в каталоге Описание Производители
TL431

100 мА, регулируемый прецизионный шунтирующий регулятор

Unisonic Technologies
Unisonic Technologies
IRF840

8 А, 500 В, N-канальный МОП-транзистор

Vishay
Vishay
LM317

Линейный стабилизатор напряжения, 1,5 А

STMicroelectronics
STMicroelectronics

DataSheet26.com    |    2020    |