SELECTION GUIDE
NMG Series
Isolated 2W Single Output DC/DC Converters
Order Code
FEATURES
„ UL 60950 recognised
„ Efficiency from 80%
„ Wide temperature performance at full
2 Watt load, –40°C to 85°C
„ UL 94V-0 package material
„ Industry standard pinout
„ 1kVDC isolation
„ 5V, 12V, 15V & 24V input
„ 5V, 9V, 12V, & 15V output
„ Internal SMD construction
„ Fully encapsulated with toroidal
magnetics
„ No external components required
„ MTTF up to 3.9 million hours
„ Pin compatible with NMR series
„ No electrolytic or tantalum capacitors
PRODUCT OVERVIEW
The NMG series of DC/DC Converters is
particularly suited to isolating and/or converting
DC power rails. The galvanic isolation allows the
device to be configured to provide an isolated
negative rail in systems where only positive rails
exist. The wide temperature range guarantees
startup from –40°C and full 2 watt output at 85°C.
Pin compatibility with the NMR and MER1 series
ensures ease of upgradeability.
V V mA mA
%
mVp-p
% % pF kHrs
NMG0505SC
5 5 400 470 5.7 7.3 28 35 81 83 33 3956
NMG0509SC
5 9 222 455 4.2 5.9 20 25 84 86.5 40 3682
NMG0512SC
5 12 167 450 3.8 5.1 18 25 84 87.5 40 3299
NMG0515SC
5 15 133 450 3.4 4.5 16 25 84 87.5 40 2833
NMG0524SC
5 24 83 465 4.3 6 35 60 82 85 35 2189
NMG1205SC
12 5 400 200 4.2 4.9 22 35 81 83.5 40 2519
NMG1209SC
12 9 222 190 2.6 3.1 16 25 83 87 61 2405
NMG1212SC
12 12 167 190 2.4 2.9 13 25 85 88 74 2235
NMG1215SC
12 15 133 185 2.0 2.4 12 25 85 88 68 2011
NMG1224SC
12 24 83 190 2.6 4 25 40 84 86.5 60 2189
NMG1505SC
15 5 400 160 4.3 6 40 60 80 83 40 3963
NMG1509SC
15 9 222 155 2.9 4.5 25 40 82 86.5 55 3176
NMG1512SC
15 12 167 150 2.4 3.5 25 40 84 87.5 65 2875
NMG1515SC
15 15 133 150 2.3 3.5 25 40 84 88 75 2483
NMG2405SC
24 5 400 100 4.1 6 40 70 80 84 45 3659
NMG2409SC
24 9 222 95 2.6 4 30 50 84 87.5 55 2496
NMG2412SC
24 12 167 95 2.1 3.5 25 50 84 88 75 3824
NMG2415SC
24 15 133 95 2 3.5 30 50 85 88.5 85 3500
When operated with additional external load capacitance the rise time of the input voltage will determine the maximum external
capacitance value for guaranteed start up. The slower the rise time of the input voltage the greater the maximum value of the
additional external capacitance for reliable start up.
INPUT CHARACTERISTICS
Parameter
Conditions
Continuous operation, 5V input types
Voltage range
Continuous operation, 12V input types
Continuous operation, 15V input types
Continuous operation, 24V input types
Reflected ripple current
Min. Typ. Max. Units
4.5 5 5.5
10.8 12 13.2
V
13.5 15 16.5
21.6 24 26.4
7.5 15 mA p-p
ABSOLUTE MAXIMUM RATINGS
Lead temperature 1.5mm from case for 10 seconds
Internal power dissipation
Input voltage VIN, NMG05 types
Input voltage VIN, NMG12 types
Input voltage VIN, NMG15 types
Input voltage VIN, NMG24 types
260°C
550mW
7V
15V
18V
28V
OUTPUT CHARACTERISTICS
Parameter
Conditions
Rated Power
TA=-40°C to 85°C
Voltage Set Point Accuracy See tolerance envelope
Line regulation
High VIN to low VIN
Min. Typ.
1.05
1. See Ripple & Noise characterisation method.
2. Calculated using MIL-HDBK-217F FN2 with nominal input voltage at full load.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
Max.
2
1.2
Units
W
%/%
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
KDC_NMG.E01 Page 1 of 7
Free Datasheet http://www.datasheetlist.com/









No Preview Available !

NMG0505SC Даташит, Описание, Даташиты
www.murata-ps.com
ISOLATION CHARACTERISTICS
Parameter
Conditions
Isolation test voltage
Flash tested for 1 second
Resistance
Viso= 1000VDC
GENERAL CHARACTERISTICS
Parameter
Conditions
Switching frequency
24V output types
All other types
TEMPERATURE CHARACTERISTICS
Parameter
Conditions
Specification
All output types
Storage
Case Temperature above 5V input types and 5V output types
ambient
All other types
Cooling
Free air convection
NMG Series
Isolated 2W Single Output DC/DC Converters
Min. Typ. Max. Units
1000 VDC
10 GΩ
Min. Typ. Max. Units
70
kHz
60
Min. Typ. Max. Units
-40 85
-50 125
°C
30
25
EFFICIENCY VS LOAD
5V Input
90
80
70
NMG0512SC
60 NMG0505SC
NMG0509SC
50 NMG0515SC
NMG0524SC
40
30
20
10
0
0 10 20 30 40 50 60 70 80 90 100
Load (%)
15V Input
90
80
70
60
50
40
30
20
10
0
0
NMG1505SC
NMG1509SC
NMG1512SC
NMG1515SC
10 20 30 40 50 60 70 80 90 100
Load (%)
12V Input
90
80
70
60 NMG1205SC
NMG1209SC
50 NMG1212SC
NMG1215SC
40 NMG1224SC
30
20
10
0
0 10 20 30 40 50 60 70 80 90 100
Load (%)
24V Input
90
80
70 NMG2405SC
NMG2409SC
60
NMG2412SC
50 NMG2415SC
40
30
20
10
0
0 10 20 30 40 50 60 70 80 90 100
Load (%)
www.murata-ps.com/support
KDC_NMG.E01 Page 2 of 7
Free Datasheet http://www.datasheetlist.com/









No Preview Available !

NMG0505SC Даташит, Описание, Даташиты
TEMPERATURE DERATING GRAPH
3
2 85°C
1 Safe Operating Area
0
-40 0 50 100 150
Ambient Temperature (°C)
NMG Series
Isolated 2W Single Output DC/DC Converters
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions NMG series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 minute.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
The NMG series has been recognized by Underwriters Laboratory for functional insulation. Both input and output should normally be maintained within SELV limits i.e. less than
42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation sys-
tem. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the
barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry
according to safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,
construction and environment. The NMG series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While
parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically
polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We
therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage.
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
SAFETY APPROVAL
The NMG series has been recognised by Underwriters Laboratory (UL) to UL 60950 for functional insulation in a maximum ambient temperature of 85ºC and/or case temperature
limit of 130ºC. Case temperature measured on the face opposite the pins. File number E151252 applies.
The NMG Series of converters are not internally fused so to meet the requirements of UL 60950 an input line fuse should always be used. An anti-surge 2A should be used for
NMG05xxSC models, and an anti-surge 0.75A should be used for NMG12xxSC models. All fuses should be UL approved and rated to at least the maximum allowable DC input
voltage.
RoHS COMPLIANCE INFORMATION
This series is compatible with RoHS soldering systems with a peak wave solder temperature of
260°C for 10 seconds. The pin termination finish is Tin Plate, Hot Dipped over Matte Tin with Nickel
Preplate. This series are backward compatible with Sn/Pb soldering systems.
For further information, please visit www.murata-ps.com/rohs
www.murata-ps.com/support
KDC_NMG.E01 Page 3 of 7
Free Datasheet http://www.datasheetlist.com/










Скачать PDF:

[ NMG0505SC.PDF Даташит ]

Номер в каталогеОписаниеПроизводители
NMG0505SCIsolated 2W Single Output DC/DC ConvertersMurata
Murata

Номер в каталоге Описание Производители
TL431

100 мА, регулируемый прецизионный шунтирующий регулятор

Unisonic Technologies
Unisonic Technologies
IRF840

8 А, 500 В, N-канальный МОП-транзистор

Vishay
Vishay
LM317

Линейный стабилизатор напряжения, 1,5 А

STMicroelectronics
STMicroelectronics

DataSheet26.com    |    2020    |

  Контакты    |    Поиск