DataSheet.es    


PDF CLAA150XP01Q Data sheet ( Hoja de datos )

Número de pieza CLAA150XP01Q
Descripción TFT LCD Module
Fabricantes CHUNGHWA PICTURE TUBES 
Logotipo CHUNGHWA PICTURE TUBES Logotipo



Hay una vista previa y un enlace de descarga de CLAA150XP01Q (archivo pdf) en la parte inferior de esta página.


Total 28 Páginas

No Preview Available ! CLAA150XP01Q Hoja de datos, Descripción, Manual

Chunghwa Picture Tubes, Ltd.
Technical Specification
To : TPK
Date : 2009-06-05
CPT TFT-LCD
CLAA 150XP01Q
ACCEPTED BY
APPROVED BY
Jason Wu
CHECKED BY
Neptune Kang
PREPARED BY
Randy Lin
Prepared by : Design General Division
CHUNGHWA PICTUER TUBES, LTD.
No. 1, Huaying Rd., Sanho Tsun, Lungtan Shiang, Taoyuan, Taiwan, 325, R.O.C.
TEL: +886-3-4805678 FAX: +886-3-4800589
Doc. No:
CLAA150XP01Q -TPK-Ver.2-2009-06-05
Issue Date: 2009/06/05

1 page




CLAA150XP01Q pdf
CPT
CHUNGHWA PICTURES TUBES, LTD.,
2. ABSOLUTE MAXIMUM RATINGS
ITEM
SYMBOL
Power Supply Voltage for LCD VCC
Lamp Voltage
VL
Lamp Current
ILO
Lamp Frequency
VESDt
static electricity
VESDc
VESDt
Operation Temperature
Top
Storage Temperature
Tstg
Delayed Discharge Time
TD
MIN.
0
-
3
-200
-8000
-200
0
-20
--
MAX.
4.0
786
8.5
200
8000
200
50
60
1
UNIT
V
Vrms
mArms
V
V
V
sec
REMARK
*4). 7)
*5)
*1). 2). 3). 6)
*1). 2). 3)
*8)
[Note]
1).The relative temperature and humidity range are as below sketch, 90%RHMax.(Ta40).
2).The maximum wet bulb temperature 39(Ta40) and without dewing.
3).If you use the product in a environment which over the definition of temperature and humidity too
long to effect the result of eye-aching.
4).The life time of the lamp is related to the current of the lamp, so please according to the description
of the “(b) backlight” on page 8.
5).Test Condition: IEC 1000-4-2
VESDt: Contact discharge to input connector; VESDC: Contact discharge to module
6).If you operate the product in normal temperature range, the center surface of panel should be under
60.
7).When lamp current is out of the absolute maximum range, the life will fall rapidly or shown
unusual sign.
IL min 2mA only for test only, but we can’t guarantee the lifetime and performance.
8).Delay lighting testing needs the volt above start voltage Vrms. Before the procedure tube needs
typical lighting for 1 minute and stay in the temperature 25±2for 24 hours and then testing in the
same condition in dark room.
CPT Confidential
5/22
CLAA150XP01Q-TPK-Ver.2-2009/06/05

5 Page





CLAA150XP01Q arduino
CPT
CHUNGHWA PICTURES TUBES, LTD.,
5. INTERFACE TIMING
(1) Timing Specifications
LCD
Timing
ITEM
DCLK
Frequency
Cycle
Vertical line rate
Horizontal Horizontal total time
Horiaontal effective time
DENA
Horizontal blank time
Vertical frame Rate
Vertical
Vertical total time
Vertical effective time
Vertical blank time
SYMBOL MIN.
fCLK
50
tCLK 12.5
fH 43.48
tH 1150
tHA --
tHB 126
Fr 55
tV 794
tVA --
tVB 26
TYP. MAX. UNIT
65 80 MHz
15.3 20 ns
48.36 58.39 kHz
1344 1370 tCLK
1024 -- tCLK
320 346 tCLK
60 75 Hz
806 860
768 --
tH
tH
38 92
tH
(2) Timing Chart
a. Horizontal Timing
b. Vertical Timing
CPT Confidential
11/22
CLAA150XP01Q-TPK-Ver.2-2009/06/05

11 Page







PáginasTotal 28 Páginas
PDF Descargar[ Datasheet CLAA150XP01Q.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
CLAA150XP01Display ModuleCHUNGHWA PICTURE TUBES
CHUNGHWA PICTURE TUBES
CLAA150XP01QTFT LCD ModuleCHUNGHWA PICTURE TUBES
CHUNGHWA PICTURE TUBES
CLAA150XP01Q-V2Display ModuleCHUNGHWA PICTURE TUBES
CHUNGHWA PICTURE TUBES
CLAA150XP01Q-ZTFT LCDCHUNGHWA PICTURE TUBES
CHUNGHWA PICTURE TUBES

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar