DataSheet26.com

W92-X112-40 PDF даташит

Спецификация W92-X112-40 изготовлена ​​​​«Tyco» и имеет функцию, называемую «Magnetic Hydraulic Circuit Breakers».

Детали детали

Номер произв W92-X112-40
Описание Magnetic Hydraulic Circuit Breakers
Производители Tyco
логотип Tyco логотип 

6 Pages
scroll

No Preview Available !

W92-X112-40 Даташит, Описание, Даташиты
W6/W9 series
Magnetic Hydraulic
Circuit Breakers
Features
• Designed for the international market. UL Recognized, CSA Certified,
and VDE approved.
• Ratings to 50 amps.
• Heavy duty #10-32 stud connections. (W9)
• Optional 10 amp auxiliary switch.
• Optional snap-in mounting. (W6)
• Several delay curve options.
• Trip-free operation.
Agency Approvals
UL: Recognized as Supplementary Protector under UL 1077. File
E69543.
CSA: Certified as a Supplementary Protector. File LR15734.
VDE: Approved to VDE 0642/EN 60 934 (Circuit Breakers for Equipment)
License No. 73782.
Electrical Data
Auxiliary Switch: See Auxiliary Switch Ratings Table 2 for details.
Calibration: Breakers will hold 100% of rated current. Breakers may trip
between 101% and 124% of rated load (149% for 400 Hz.
units and 134% for AC/DC units). Breakers must trip at
125% of rated load and above (150% for 400 Hz. units and
135% for AC/DC units).
Dielectric Strength: 50/60 or 400 Hz., 1500V: DC, 1100V.
Insulation Resistance: 100 Megohms at 500VDC.
Endurance: 10,000 on/off cycles - 6000 at rated load, 4000 at no load.
Units tested at six cycles per minute, 1 second on and 9
seconds off at 25°C ambient.
Approvals and Ratings Table 1
W6 Series
UL/CSA (All Circuit Functions)
Maximum
Voltage
65
277
277
277/480
250
250
250
Frequency
(Hz)
DC
50/60
50/60
50/60
400
400
400
Current
Phase
-
1
1
3Ø-Wye
1
1
3Ø-Wye
Interrupting
Rating
(Amps)
0.2 - 50
0.2 - 20
21 - 50
0.2 - 20
0.2 - 20
21 - 50
0.2 - 20
W9 Series
Maximum
Voltage
65
277
277/480
250
250
UL/CSA (All Circuit Functions)
Frequency
(Hz)
Current
Phase
Interrupting
Rating
(Amps)
DC
50/60
50/60
400
400
-
1
3Ø-Wye
1
3Ø-Wye
0.2 - 50
0.2 - 50
0.2 - 20
0.2 - 50
0.2 - 50
Capacity
(Amps)
2,000
5,000
2,500
5,000
2,500
1,250
2,500
Capacity
(Amps)
2,000
5,000
5,000
2,500
2,500
Approvals and Ratings Table 2
UL/CSA
Switch
Number
A
Voltage
50/60 Hz.
125
Current
(Amps)
10
Terminals
WxTxL
.093 x .020 x .250
(2.36 x .51 x 6.40)
Typical Resistance and Impedance
DC 50/60 Hz.
Current
Resistance
Impedance
(Amps)
(Ohms)
(Ohms)
0.2 90
90
1.0 1.2
1.2
2.0 0.28 0.28
5.0 0.04 0.04
10.0
0.013
0.013
20.0
0.004
0.005
30.0
0.0027
0.004
40.0
0.002
0.002
50.0
0.0015
0.0015
400 Hz.
Impedance
(Ohms)
180
2.0
0.50
0.05
0.025
0.0065
0.004
0.003
0.0025
Tolerance: 0.1 - 4.99 ± 15%; 5 - 9.99 ± 20%; 10 - 15 ± 25%; 16 - 30 ± 50%.
Mechanical/Environmental Data
Operating Temperature: -40°C to +85°C.
Humidity: Meets requirements of Mil-STD-202 method 103.
Shock: Tested per Mil-STD-202, method 213, test condition C
(100g @ 6 ms).
Vibration:Tested per Mil-STD-202, method 201, 10-55 Hz., 0.06" (1.52mm)
total excursion in 2 planes.
Fungus And Moisture Resistance: Special moisture resistant finish
applied to all ferrous parts.
Plastic parts are made of inherently
fungus resistant material.
Marking: W6 units have ON and OFF molded on the rocker of rocker
actuated units (rocker actuated VDE units have international
“1” and “0”). W9 units have ON and OFF molded into the area
at the base of the toggle. International “1” and “0” symbols are
marked on the toggle for both W6 and W9.
Mounting: Panel mounted units are mounted with two #6-32 screws
from the front of the panel. Metric models for use with M3 x
0.5 screws are available. Units with snap-in mounting option
snap through the front of the panel. To maintain published
performance specifications, units should not be mounted
more than 90° from their normal upright position.
Weight: Approximately 2.5 ounces per pole.
W6 Series
Maximum
Voltage
65
250
250
415/240
VDE (Circuit Function X)
Frequency
(Hz)
Current
Phase
Interrupting
Rating
(Amps)
DC
50/60
50/60
50/60
-
1
1
0.2-50
0.2-30
31-50
0.2-30
Capacity
(Amps)
2,000
5,000
2,000
5,000
W9 Series
Maximum
Voltage
65
250
250
415/240
VDE (Circuit Function X)
Frequency
(Hz)
Current
Phase
Interrupting
Rating
(Amps)
DC
50/60
50/60
50/60
-
1
1
0.2-50
0.2-30
31-50
0.2-30
Capacity
(Amps)
2,000
5,000
2,000
5,000
VDE
Switch
Number
V1
V2
V3
Voltage
50/60 Hz.
250
250
250
Current
(Amps)
10
5
0.1
Terminals
WxTxL
.110 x .020 x .280
(2.79 x .51 x 7.11)









No Preview Available !

W92-X112-40 Даташит, Описание, Даташиты
Time vs. Current Trip Curves For W6 Series and W9 Series
AC 50/60 Hz.
400 Hz.
10,000
1000
100
10
1
DC & 50/60 Hz.
CURVE 0 NON-TIME DELAY
TRIP TIMES
OVERLOAD @ 50/60 Hz. & DC @ 400 Hz.
125%
150%
200%
400%
600%
800%
100 ms max.
55 ms max.
30 ms max.
15 ms max.
12 ms max.
12 ms max.
May Trip
100 ms max.
30 ms max.
15 ms max.
12 ms max.
12 ms max.
.1
.01
.001
0
100 200 300 400 500 600 700 800 900 1000 1100 1200
125 150
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
10,000
1000
100
10
1
CURVE 2 AC VOLTAGE 50/60 Hz.
OVERLOAD TRIPTIMES
(SEC.)
125%
200%
400%
600%
800%
1000%
10 - 150
2.2 - 20
.2 - 2
.03 - .75
.007 - .15
.005 - .04
.1
.01
.001
0
100 200 300 400 500 600 700 800 900 1000 1100 1200
125 150
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
10,000
1000
100
10
1
CURVE 3 AC VOLTAGE 50/60 Hz.
OVERLOAD TRIPTIMES
(SEC.)
125%
200%
400%
600%
800%
1000%
1 - 15
.15 - 1.5
.03 - .25
.007 - .15
.003 - .08
.003 - .04
.1
.01
.001
0
100 200 300 400 500 600 700 800 900 1000 1100 1200
125 150
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
10,000
1000
100
10
MOTOR START
CURVE 10 HIGH INRUSH 50/60 Hz. AC
OVERLOAD TRIPTIMES
(SEC.)
125%
200%
400%
600%
800%
1000%
40 - 500
9 - 100
2 - 20
.8 - 10
.1 - 4.5
.009 - 2
1
.1
.01
.001
0
100 200 300 400 500 600 700 800 900 1000 1100 1200
125 150
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
DC
10,000
1000
100
10
1
CURVE 2 DC VOLTAGE
OVERLOAD TRIPTIMES
(SEC.)
125%
200%
400%
600%
800%
1000%
2 - 55
.60 - 8
.1 - 1.5
.02 - .5
.004 - .05
.004 - .025
.1
.01
.001
0
100 200 300 400 500 600 700 800 900 1000 1100 1200
125 150
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
10,000
1000
100
10
1
CURVE 12 HIGH INRUSH 50/60 Hz.
OVERLOAD TRIPTIMES
(SEC.)
125%
200%
400%
600%
800%
1000%
10 - 150
3 - 25
.5 - 2.5
.15 - 1
.015 - .7
.009 - .35
.1
.01
.001
0
100 200 300 400 500 600 700 800 900 1000 1100 1200
125 150
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
10,000
1000
100
10
1
CURVE 3 DC VOLTAGE
OVERLOAD TRIPTIMES
(SEC.)
125%
200%
400%
600%
800%
1000%
.6 - 7
.16 - 1.5
.03 - .25
.01 - .13
.004 - .05
.003 - .015
.1
.01
.001
0
100 200 300 400 500 600 700 800 900 1000 1100 1200
125 150
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
10,000
1000
100
10
1
CURVE 13 HIGH INRUSH 50/60 Hz.
OVERLOAD TRIPTIMES
(SEC.)
125%
200%
400%
600%
800%
1000%
.8 - 30
.15 - 2.5
.03 - .3
.02 - .15
.009 - .12
.009 - .09
.1
.01
.001
0
100 200 300 400 500 600 700 800 900 1000 1100 1200
125 150
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
10,000
1000
100
10
CURVE 53 DC HIGH INRUSH
OVERLOAD TRIPTIMES
(SEC.)
125%
200%
400%
600%
800%
1000%
80 - 700
15 - 150
2 - 20
.70 - 10
.10 - 3
.01 - .1
1
.1
.01
.001
0
100 200 300 400 500 600 700 800 900 1000 1100 1200
125 150
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
AC/DC
AC 400 Hz.
10,000
1000
100
10
1
CURVE 34 DC, 50/60 Hz. STANDARD DELAY
OVERLOAD TRIPTIMES
(SEC.)
135%
200%
400%
600%
800%
1000%
1 - 90
.60 - 20
.095 - 2
.02 - .95
.002 - .45
.002 - .09
10,000
1000
100
10
1
CURVE 2 AC VOLTAGE 400 Hz.
OVERLOAD TRIPTIMES
(SEC.)
150%
200%
400%
600%
800%
1000%
5 - 60
2.2 - 20
.3 - 3.2
.01 - .17
.006 - .06
.005 - .045
.1 .1
.01 .01
.001
0
100 200 300 400 500 600 700 800 900 1000 1100 1200
125 150
LOAD CURRENT AS A PERCENT
135 OF BREAKER RATING
.001
0
100 200 300 400 500 600 700 800 900 1000 1100 1200
125 150
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
Note:
For instantaneous curves for all voltages refer to Curve 0 Non-Time Delay under the AC 50/60 Hz. heading.
Pulse Tolerance Specifications
Pulse tolerance is defined as a single pulse of a half sine
wave (1/2 cycle or 8 milliseconds) that will not trip the
breaker. An inertia wheel for increased pulse tolerance is
available by specifying “P” after the time delay curve
number in the ordering information. The table at right lists
pulse tolerance values of standard and inertia delay models.
Voltage
AC
50/60 Hz.
AC
400 Hz.
Time
Delay
Curve
2
3
10
12
13
2
3
10,000
1000
100
10
1
CURVE 3 AC VOLTAGE 400 Hz.
OVERLOAD TRIPTIMES
(SEC.)
150%
200%
400%
600%
800%
1000%
.55 - 5.5
.18 - 2
.02 - .2
.006 - .075
.004 - .05
.004 - .035
.1
.01
.001
0
100 200 300 400 500 600 700 800 900 1000 1100 1200
125 150
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
Pulse Tolerance Value
Standard
Inertia
Delay
7.5 18
6 18
18 30
18 30
18 30
6.5 18
5.5 18
To determine pulse tolerance multiply breaker rating by value in table. For
example, a 2A breaker with time delay curve 3 has a standard pulse tolerance
of 12A (2A x 6). The same breaker with an inertia delay has a pulse tolerance
of 36A (2A x 18).









No Preview Available !

W92-X112-40 Даташит, Описание, Даташиты
Ordering Information
W6 Series
Typical Part No. B W 67- X 2 Q 1 2- 20
1. Circuit Breaker Mounting:
W = #6-32 mounting threads.
M = M3.0 x 0.5 mounting threads.
X = Snap-in mounting. (Not available in rocker actuated models.)
2. Number of Poles:
67 = Single pole
68 = Two pole
69 = Three pole
70 = Four pole
3. Circuit Function: (Only X is VDE approved)
A = Series trip with auxiliary switch (.093” QC)
X = Series trip
4. Actuator: (One actuator per pole)
1 = Black toggle 3 = Black rocker
2 = White toggle 4 = White rocker
5 = Red rocker
6 = Grey rocker
9 = Red toggle
5. Termination:
Q = .250” QC (DIN 46 244) 25A Max. VDE
S = #8-32 screw
Note: “T” termination must be used for all ratings of 31 amps or above.
T = #10-32 screw
6. Maximum Line Voltage: (See Table 1 for current ranges)
UL/CSA 1 = 277VAC, 50/60 Hz.
VDE
TYPES 2 = 277/480
TYPES
3 = 250VAC, 400 Hz.
5 = 65VDC
7 = AC/DC 277VAC or 65VDC
(Delay curve 34 must be specified.)
1 = 250VAC, 415/240VAC
5 = 65VDC
7 = AC/DC 250VAC, 415/240VAC, 65VDC
(Delay curve 34 must be specified.)
7. Time Delay Curve:
0 = Instantaneous
2 = Standard delay
3 = Short delay
53 = DC high inrush
10 = AC high inrush (Motor start)
12 = AC high inrush version of #2
13 = AC high inrush version of #3
34 = Combination AC/DC standard delay
Notes: Curves may be specified with increased pulse tolerance for 1/2 cycle by
adding "P" after curve, See delay curve section for availability and details.
8. Amp Rating:
0.20 0.50
0.25 0.75
1.0
1.5
2.0 3.0
2.5 3.5
4.0 6.0
7.5
9.0 11.0 15.0 25.0 35.0 45.0 Consult factory for
5.0 7.0
8.0 10.0 12.0 20.0 30.0 40.0 50.0 other values.
9. VDE Approval: (See Table 2 for auxiliary switch ratings)
Blank = UL/CSA approved breaker
V = VDE approved breaker without auxiliary switch
V1 = VDE approved breaker with 10 amp VDE auxiliary switch
V2 = VDE approved breaker with 5 amp VDE auxiliary switch
V3 = VDE approved breaker with 0.1 amp VDE auxiliary switch
Stock Items - We recommend that our authorized distributors stock the following items for immediate delivery.
W67-A2Q12-5
W67-A2Q12-10
W67-X2Q10-3
W67-X2Q10-5
W67-X2Q12-2
W67-X2Q12-3
W67-X2Q12-5
W67-X2Q12-7
W67-X2Q12-10
W67-X2Q12-15
W67-X2Q12-20
W67-X2Q12-30
W67-X2Q13-1
W67-X2Q13-2
W67-X2Q13-3
W67-X2Q13-10
W67-X2Q13-15
W67-X2Q13-20
W67-X2Q13-25
W67-X2Q13-30
W67-X2Q50-5
W67-X2Q50-10
W67-X2Q52-5
W67-X2Q52-10
W67-X2Q52-15
W67-X2Q52-20
W67-X2Q52-30
W67-X2Q110-15
W67-X2Q110-20
W68-X2Q12-3
W68-X2Q12-5
W68-X2Q12-7
W68-X2Q12-10
W68-X2Q12-15
W68-X2Q12-20
W68-X2Q12-25
W68-X2Q12-30
W68-X2Q13-15
W68-X2Q110-10
W68-X2Q110-20
W69-X2Q12-5
W69-X2Q12-10
W69-X2Q12-15
W69-X2Q12-20
W69-X2Q12-25
W69-X2Q12-30
W69-X2Q110-20
W69-X2Q110-30
Ordering Information
W9 Series
Typical Part No. B W 91- X 1 1 2- 20
1. Circuit Breaker Mounting:
W = #6-32 mounting threads.
M = M3.0 x 0.5 mounting threads.
2. Number of Poles:
91 = Single pole
92 = Two pole
93 = Three pole
94 = Four pole
3. Circuit Function: (Only X is VDE approved)
A = Series trip with auxiliary switch (.093” QC)
X = Series trip
4. Actuator: (One actuator per pole):
1 = Black toggle
2 = White toggle
5. Maximum Line Voltage: (See Table 1 for current ranges)
UL/CSA 1 = 277VAC, 50/60 Hz.
VDE 1 = 250VAC, 415/240VAC
TYPES 2 = 277/480
TYPES 5 = 65VDC
3 = 250VAC, 400 Hz.
7 = AC/DC 250VAC, 415/240VAC, 65VDC
5 = 65VDC
(Delay curve 34 must be specified.)
7 = AC/DC 277VAC or 65VDC
(Delay curve 34 must be specified.)
6. Time Delay Curve:
0 = Instantaneous
2 = Standard delay
3 = Short delay
53 = DC high inrush
10 = AC high inrush (Motor start)
12 = AC high inrush version of #2
13 = AC high inrush version of #3
34 = Combination AC/DC standard delay
Notes: Curves may be specified with increased pulse tolerance for 1/2 cycle
by adding "P" after curve. See delay curve section for availability and details.
7. Amp Rating:
0.20 0.75
0.25 1.0
0.50 1.5
2.0
2.5
3.0
3.5 6.0
4.0 7.0
5.0 7.5
8.0
9.0
10.0
11.0
12.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
Consult factory for other values
8. VDE Approval: (See Table 2 for auxiliary switch ratings)
Blank = UL/CSA approved breaker
V = VDE approved breaker without auxiliary switch
V1 = VDE approved breaker with 10 amp VDE auxiliary switch
V2 = VDE approved breaker with 5 amp VDE auxiliary switch
V3 = VDE approved breaker with 0.1 amp VDE auxiliary switch
Stock Items - We recommend that our authorized distributors stock the following items for immediate delivery.
W91-X112-1
W91-X112-2
W91-X112-3
W91-X112-5
W91-X112-7
W91-X112-10
W91-X112-15
W91-X112-20
W91-X112-40
W91-X112-50
W91-X113-5
W91-X113-10
W91-X113-15
W91-X150-5
W91-X152-10
W91-X152-15
W91-X152-20
W91-X152-30
W91-X152-40
W91-X152-50
W91-X1110-20
W92-X112-1
W92-X112-2
W92-X112-3
W92-X112-5
W92-X112-7
W92-X112-10
W92-X112-15
W92-X112-20
W92-X112-25
W92-X112-30
W92-X112-40
W92-X112-50
W92-X113-15
W92-X113-20
W92-X1110-20
W92-X1110-30
W93-X112-5
W93-X112-10
W93-X112-15
W93-X112-20
W93-X112-25
W93-X112-30
W93-X112-40
W93-X112-50
W93-X1110-20
W93-X1110-30










Скачать PDF:

[ W92-X112-40.PDF Даташит ]

Номер в каталогеОписаниеПроизводители
W92-X112-40Magnetic Hydraulic Circuit BreakersTyco
Tyco

Номер в каталоге Описание Производители
TL431

100 мА, регулируемый прецизионный шунтирующий регулятор

Unisonic Technologies
Unisonic Technologies
IRF840

8 А, 500 В, N-канальный МОП-транзистор

Vishay
Vishay
LM317

Линейный стабилизатор напряжения, 1,5 А

STMicroelectronics
STMicroelectronics

DataSheet26.com    |    2020    |

  Контакты    |    Поиск