DataSheet26.com

CC6-4812Sx-E PDF даташит

Спецификация CC6-4812Sx-E изготовлена ​​​​«TDK-Lambds» и имеет функцию, называемую «Insulation type DC-DC converter».

Детали детали

Номер произв CC6-4812Sx-E
Описание Insulation type DC-DC converter
Производители TDK-Lambds
логотип TDK-Lambds логотип 

25 Pages
scroll

No Preview Available !

CC6-4812Sx-E Даташит, Описание, Даташиты
CC-E
±
1
5
±±
web 140630









No Preview Available !

CC6-4812Sx-E Даташит, Описание, Даташиты
CC1R5-E
CC1R5-E Specifications
2
Input
Output
Function
Environment
Isolation
Standards
Mechanical
Nominal Voltage
Voltage Range
Efficiency (typ)
(*1)
Current (typ)
(*1)
Nominal Voltage
Maximum Current
Maximum Power
(*2)
Maximum Line Regulation (Within input voltage range)
Maximum Load Regulation (0-100% load) (*3)
Temperature Coefficient
(Ambient temperature–40 C to +50 C)
Max Power Total Regulation (max)(*4)
Maximum Ripple & Noise (typ/max) (*5)
Voltage Adjustable Range
Over Current Protection
(*6)
Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Vibration
Shock
Withstand Voltage
Isolation Resistance
Safety Standards
Weight (typ)
Size (W x H x D)
V
V
A
VDC
A
W
mV
mV
mVp-p
VDC
RH
RH
g
mm
71 77
0.372
0.390
3.3 5
0.400
0.300
1.32
20
40
DC5.0
DC4.5-9.0
80
0.375
12 15
0.125
0.100
1.5
40
100
12
0.060
79
0.380
15
0.050
80
600
80mV
200mV
300mV
35
40/120
30/120
3.15-3.6
4.75-6.0
11.4-15.0
11.4- 15.0
Available
Not available
Available
-40 to +85
-40 to +85
5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
3.2
DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately.
Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25 C.
(*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25 C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
Input
Output
Function
Environment
Isolation
Standards
Mechanical
Nominal Voltage
Voltage Range
Efficiency (typ)
(*1)
Current (typ)
(*1)
Nominal Voltage
Maximum Current
Maximum Power
(*2)
Maximum Line Regulation (Within input voltage range)
Maximum Load Regulation (0-100% load) (*3)
Temperature Coefficient
(Ambient temperature–40 C to +50 C)
Max Power Total Regulation (max)(*4)
Maximum Ripple & Noise (typ/max) (*5)
Voltage Adjustable Range
Over Current Protection
(*6)
Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Vibration
Shock
Withstand Voltage
Isolation Resistance
Safety Standards
Weight (typ)
Size (W x H x D)
V
V
A
VDC
A
W
mV
mV
mVp-p
VDC
RH
RH
g
mm
73 78
0.151
0.160
3.3 5
0.400
0.300
1.32
20
40
DC12
DC9.0-18
82
0.152
12 15
0.125
0.100
1.5
40
100
12
0.060
81
0.154
15
0.050
80
600
80mV
200mV
300mV
35
40/120
30/120
3.15-3.6
4.75-6.0
11.4-15.0
11.4 - 15.0
Available
Not available
Available
-40 to +85
-40 to +85
5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
3.2
DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately.
Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25 C.
(*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25 C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.









No Preview Available !

CC6-4812Sx-E Даташит, Описание, Даташиты
CC1R5-E
3
Input
Output
Function
Environment
Isolation
Standards
Mechanical
Nominal Voltage
Voltage Range
Efficiency (typ)
(*1)
Current (typ)
(*1)
Nominal Voltage
Maximum Current
Maximum Power
(*2)
Maximum Line Regulation (Within input voltage range)
Maximum Load Regulation (0-100% load) (*3)
Temperature Coefficient
(Ambient temperature–40 C to +50 C)
Max Power Total Regulation (max)(*4)
Maximum Ripple & Noise (typ/max) (*5)
Voltage Adjustable Range
Over Current Protection
(*6)
Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Vibration
Shock
Withstand Voltage
Isolation Resistance
Safety Standards
Weight (typ)
Size (W x H x D)
V
V
A
VDC
A
W
mV
mV
mVp-p
VDC
RH
RH
g
mm
72 77
0.076
0.081
3.3 5
0.400
0.300
1.32
20
40
12
0.125
DC24
DC18-36
81
0.077
40
100
15
0.100
1.5
12
0.060
79
0.079
15
0.050
80
600
80mV
200mV
300mV
35
40/120
30/120
3.15-3.6
4.75-6.0
11.4-15.0
11.4- 15.0
Available
Not available
Available
-40 to +85
-40 to +85
5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
3.2
DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately.
Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25 C.
(*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25 C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
Input
Output
Function
Environment
Isolation
Standards
Mechanical
Nominal Voltage
Voltage Range
Efficiency (typ)
(*1)
Current (typ)
(*1)
Nominal Voltage
Maximum Current
Maximum Power
(*2)
Maximum Line Regulation (Within input voltage range)
Maximum Load Regulation (0-100% load) (*3)
Temperature Coefficient
(Ambient temperature–40 C to +50 C)
Max Power Total Regulation (max)(*4)
Maximum Ripple & Noise (typ/max) (*5)
Voltage Adjustable Range
Over Current Protection
(*6)
Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Vibration
Shock
Withstand Voltage
Isolation Resistance
Safety Standards
Weight (typ)
Size (W x H x D)
V
V
A
VDC
A
W
mV
mV
mVp-p
VDC
RH
RH
g
mm
70 76
0.039
0.041
3.3 5
0.400
0.300
1.32
20
40
12
0.125
DC48
DC36-76
80
0.039
40
100
15
0.100
1.5
12
0.060
79
0.040
15
0.050
80
600
80mV
200mV
300mV
35
40/120
30/120
3.15-3.6
4.75-6.0
11.4-15.0
11.4- 15.0
Available
Not available
Available
-40 to +85
-40 to +85
5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
3.2
DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately.
Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25 C.
(*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25 C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.










Скачать PDF:

[ CC6-4812Sx-E.PDF Даташит ]

Номер в каталогеОписаниеПроизводители
CC6-4812Sx-EInsulation type DC-DC converterTDK-Lambds
TDK-Lambds

Номер в каталоге Описание Производители
TL431

100 мА, регулируемый прецизионный шунтирующий регулятор

Unisonic Technologies
Unisonic Technologies
IRF840

8 А, 500 В, N-канальный МОП-транзистор

Vishay
Vishay
LM317

Линейный стабилизатор напряжения, 1,5 А

STMicroelectronics
STMicroelectronics

DataSheet26.com    |    2020    |