DataSheet26.com

SEM1620 PDF даташит

Спецификация SEM1620 изготовлена ​​​​«Status Instruments» и имеет функцию, называемую «UNIVERSAL DIN RAIL TRANSMITTER».

Детали детали

Номер произв SEM1620
Описание UNIVERSAL DIN RAIL TRANSMITTER
Производители Status Instruments
логотип Status Instruments логотип 

2 Pages
scroll

No Preview Available !

SEM1620 Даташит, Описание, Даташиты
UNIVERSAL DIN RAIL TRANSMITTER
SEM1620
SIMPLE CONFIGURATION VIA USB PORT
UNIVERSAL PT100, THERMOCOUPLE, mV, mA Input
ISOLATED INPUT
PUSH BUTTON USER TRIM
THREE WIRE ISOLATED VOLTAGE OUTPUT
INTRODUCTION
The SEM1620 is the new generation DIN rail mounted temperature amplifier from Status Instruments. It has been designed to accept
most common process and temperature sensor inputs and provide the user with a three wire voltage output signal. Isolation is
provided between input and output and all temperature ranges are linear to temperature.
Designed for ease of use, our latest USB interface is fitted for quick and easy configuration. Just connect a standard USB cable
between the SEM1620 and your PC. Using our free configuration software, your PC will automatically upload the existing
configuration data and guide you through any changes you wish to make. To further help save time, the SEM1620 does not need to be
wired to a power supply during the configuration process, it is powered via the USB interface from your PC. The following parameters
are configurable :-
INPUT TYPE
LOW RANGE HIGH RANGE
UNITS
OUTPUT
BURNOUT
USER TRIM
PT100
T/C K, J, E, N, T, R, S
mV
Input @ 4 mA Input @ 20 mA
°F, °C
°F, °C
mV
(0 to 10) V
(2 to 10) V
(0 to 5) V
(1 to 5) V
(0 to 1) V
Up/Scale
Down/Scale
On , Off
mA mA
The SEM1620 is also provided with user push button trim, allowing trim adjustments at both offset and span. The user trim function
can be locked during configuration if not required. The range led indicates out of range input during normal operation, during user
trim it is used to indicate the stage of trim.
SEM1620
+ 10
mA PT100
+
mV
--
9
+8
-7
Universal Input
USB
+
6
5
Volt
Output
4
-
+
Vo
-
+
Volt
V s Supply
-
Three Wire Voltage Output









No Preview Available !

SEM1620 Даташит, Описание, Даташиты
UNIVERSAL DIN RAIL TRANSMITTER
SPECIFICATION @ 20 °C
INPUTS
INPUT
RANGE
ACCURACY
(Note 1)
K (-200 to 1370) °C 0.1 % of FSR ±0.5 °C
J (-100 to 1200) °C (type T 0.2 % FSR. ± 0.5 °C)
E (-100 to 1000) °C
N (-180 to 1300) °C
T (-100 to 400) °C
R (-10 to 1760) °C ± 0.5 °C ±0.1 % of FSR
(Note 2)
S (-10 to 1760) °C ± 0.5 °C ±0.1 % of FSR
(Note 2)
mV (-40 to 75) mV ± 0.04 mV
P (-200 to 850) °C ± 0.1 °C / ±0.05 % of rdg
mA (-10 to 25) mA ± 0.008 mA
(4 to 20) mA
Capability
STABILITY
(Note 7)
± 0.01 % of FSR / °C
O/C CJ
Sensor IMPEDANCE
(Note 3) excitation
(Note 4)
Yes Yes
-
1 M
(Note 5)
± 0.005 % of FSR / °C
± 0.01 % of FSR / °C -
-
-
-
<450 uA
-
-
2.7 R
(Note 6)
Key Rdg = Reading ; FSR = Full Scale Range ; O/C = programmable open circuit sensor detect; CJ = Cold junction error
Notes
1. Accuracy for PT100 and T/C do not include sensor and cold junction errors.
2. Only over the range (800 to 1600) °C
3. Cold junction range (-20 to 70) °C, Accuracy ± 0.5 °C , Tracking ± 0.05 °C
4. PT100 input Maximum lead resistance 20 R, Lead effect 0.015 °C / .
5. Impedance – not including 0.2 uA open circuit detect bias current effect.
6. Maximum current over load ± 100 mA.
7. Ambient (-10 to 50) °C
OUTPUT
Type
Supply
Response time
Calibration Accuracy
Output Drive
Protection
User Trim
Stability
Three Wire voltage output with programmable ranges. (0 to 10), (0 to 5), (2 to 10), (1 to 5), and (0 to 1) V
(15 to 28) V dc . Current 10mA MAX.
< 500 ms to reach 95 % of final value ; Start up time < 3 s
± 5 mV
2 mA driving 5 K@ 10 V
Reverse connection and over-voltage protection. Max over voltage current 100 mA.
Raise and lower buttons, active for offset when output is at offset and span. Trim lock option.
± 1 mV / °C
GENERAL
Isolation
Ambient
Approvals
Input to output tested at 500 V dc.
operating (-20 to 70) °C (10 to 95) % RH non condensing. Storage (-40 to 85) °C
CE tested to BS EN 61326
12 3
45 6
REFER TO
INSTRUCTION MANUAL
BEFORE USE
1
2
78 9
10 11 12
17.5mm
56.4mm
90 mm
MECHANICAL DETAIL
Material
Terminals
Cable
Colour
Polymide 6.6
self extinguishing
Screw terminal
2.5 mm Max
Grey
ORDER CODE : SEM1620
ASSOCIATED PRODUCTS
USB CABLE A/M TO MINI B/M
USB Link Software
ORDER CODES
48-200-0001-01
F0C @ www.status.co.uk Downloads
SEM1603P / TC / I
SEM1610
SEM1630
LOW COST SINGLE I/P DIN RAIL TRANSMITTER
UNIVERSAL DIN RAIL TRANSMITTER (4 to 20) mA O/P
UNIVERSAL DIN RAIL TRIP AMPLIFIER
Status Instruments Ltd
Status Business Park
Gannaway Lane, Tewkesbury
Gloucestershire, UK
GL20 8FD
Tel: +44 (0)1684 296818
Fax: +44 (0)1684 293746
Website: www.status.co.uk
D2445-01-06 CN5219 SEM1620 Data Sheet










Скачать PDF:

[ SEM1620.PDF Даташит ]

Номер в каталогеОписаниеПроизводители
SEM1620UNIVERSAL DIN RAIL TRANSMITTERStatus Instruments
Status Instruments

Номер в каталоге Описание Производители
TL431

100 мА, регулируемый прецизионный шунтирующий регулятор

Unisonic Technologies
Unisonic Technologies
IRF840

8 А, 500 В, N-канальный МОП-транзистор

Vishay
Vishay
LM317

Линейный стабилизатор напряжения, 1,5 А

STMicroelectronics
STMicroelectronics

DataSheet26.com    |    2020    |

  Контакты    |    Поиск