DataSheet26.com

NJBK7 PDF даташит

Спецификация NJBK7 изготовлена ​​​​«CHiNT» и имеет функцию, называемую «Motor Protection Relay».

Детали детали

Номер произв NJBK7
Описание Motor Protection Relay
Производители CHiNT
логотип CHiNT логотип 

4 Pages
scroll

No Preview Available !

NJBK7 Даташит, Описание, Даташиты
2. Type designation
N JBK 7 - 800 / □
Relay
Protection Relay
NJBK7 Motor protection delay
1. General
NJBK7 series motor protection relay (hereinafter
referred to as protector) is used to provide overload, locked
rotor, phase failure, three-phase current unbalance, ground
and PTC temperature protection for AC motors with a
frequency of AC 50Hz, a rated insulation voltage of up to
690V and a rated operational current of 80A-800A that
operate continuously or intermittently. The protector uses
flexible Rogowski coil to acquire current and features wide
setting current range, high accuracy and convenient
installation. The protector has RS485 interface and 4mA-
20mA analog transmission interface, permits network
communication and can realize remote monitor and
control and fault inquiry of motors by means of upper
computer. The protector is genenrally used in combination
with AC contactor.
Standards: GB 14084.4, IEC 60947-4-1.
Rated control supply voltage
(AC220, AC380, AC/DC100V-240V)
Specification code
Design sequence No.
Motor protection relay
Company code
3. Technical data
3.1 Altitude: should not exceed 2000m;
3.2 Ambient tempeature: -5~+40, and the average
temperature in 24h should not exceed +35;
3.3 Atmospheric conditions: The relative air humidity should not
exceed 50% at the maximum temperature of +40. The
relative humidity may be higher at lower temperatures, for
example, the air humidity can be up to 90% at +20. Special
measures should be taken if condensation occurs on the product
occasionally due to temperature variation;
3.4 Pollution degree: 3;
3.5 The inclination between the mounting plane and the vertical
plane should not exceed ±5°;
3.6 In non-explosive media that do not contain a sufficient
amount of gas or conductive dust to cause metal corrosion or
insulation failure;
3.7 In places with rain and snow protection equipment and not
full of vapor;
3.8 In places where there is no significant shake, impact or
vibration;
3.9 Mounting category: Ⅲ;
3.10 Degree of protection of enclosure: Ip20.
I-19
> >>









No Preview Available !

NJBK7 Даташит, Описание, Даташиты
Relay
Protection Relay
4. Main data and technical characteristics
4.1 Main circuit: rated insulation voltage: AC690V, rated frequency: 50Hz
Model
NJBK7-800/
Setting current (A)
800
Setting current range (A)
80~800
Matching motor power (kW)
40~400
4.2 Auxiliary circuit: rated insulation voltage: AC380V, rated frequency: 50Hz, data of auxiliary contact
Usage category
Rated operational voltage Ue(V)
Rated operational current Ie(A)
Conventional heating current Ith(A)
240
1.5
AC-15
5
380
0.95
4.3 Structural features
4.3.1 Split mounting;
4.3.2 LCD display, key setting;
4.3.3 Has start delay function;
4.3.4 Has fault memory function, permits inquiry of fault record;
4.3.5 Has RS485 interface, supports MODBUS protocol, permits network communication;
4.3.6 Has 4mA-20mA analog output interface;
4.3.7 Has two groups of output contacts, 1Z protection contact and 1H auxiliary contact, and permits autotransformer reduced voltage
starting and star-delta starting;
4.3.8 Power consumption: ≤3VA.
5. Protection charactersitics
5.1 Operating characteristics of overload protection
Overload
curve
Kr=1
Kr=2
Kr=3
Kr=4
Kr=5
Overload multiple
Operation
time (s)
1.1 1.2 1.5
2
5
6 7.2
75 63 40 22 3.6 2.5 1.8
150 125 80 45 7.2 5 3.5
298 250 160 90 14 10 6.9
595 500 320 180 29 20 14
892 750 480 270 43 30 21
Note
In conformity with Class 10A
In conformity with Class 10
In conformity with Class 20
In conformity with Class 30
5.2 Operating characteristics of phase failure protection
When the current of any phase of the three-phase current of
the main circuit is equal to zero, the protector operates for a
period of ≤5s.
5.3 Operating characteristics of three-phase current unbalance
protection
When the three-phase current of the main circuit meets the
following formula, the protector operates for a period of ≤5s.
Imax-Imin
Imax ×100% set current unbalance rate
Imax: Max. phase current value
Imin: Min. phase current value
5.4 Operating characteristics of ground protection
When zero sequence current set ground protection
current value, the protector operates for a period of ≤1s.
5.5 Operating characteristics of locked rotor protection
When Max. phase current setting current value×set
locked rotor multiple, the protector operates for a period of
1s.
5.6 Operating characteristics of temperature protection
The over-temperature protection function of the protector is
accomplished by detecting the resistance of the PTC thermistor
preembedded in the motor stator widing. When the resistance
of the PTC thermistor ≥2.5kΩ, the protector operates for a
period of ≤1s.
5.7 Communication: The protector provides RS485 interface and
supports MODBUS protocol.
Tripping characteristic curve
100min
50min
20min
10min
5min
2min
1min
5S
2S
1S
1
2
Kr=5
Kr=4
Kr=3
Kr=2
Kr=1
58
×Iset
I
> >> I-20









No Preview Available !

NJBK7 Даташит, Описание, Даташиты
6. Connection diagram
Figure 1 Direct starting connection diagram in case the control
supply voltage is 220V and the rated operational voltage is 220V
L1 L2 L3 N
QF
SB2 SB1 KM1
KM1
KM1
CT 1 2 3 4 5 6 7
A1 A2 07 08 98 95 96
NJBK7 Motor protection delay
10 C1
11 C2 T1
12
T2
13
PE
8 9 14
M 4mA~20mA
3~
Figure 2 Secondary current direct starting connection diagram in
case the control supply voltage is 220V and the rated operational
voltage is 220V
Relay
Protection Relay
Figure 4 Star-delta starting connection diagram in case the
control supply voltage is 220V and the rated operational voltage
is 220V
KM3
L1 L2 L3 N
QF
KM1
SB2 SB1 KM2 KM3 KA
KM2
KA KM3KM2
KM2
KM1
KA
KM1
KA
CT
M
3~
1 23456 7
A1 A2 07 08 98 95 96
10 C1 NJBK7电动机保护继电器
11 C2 T1 T2
12 13
PE
8 9 14
4mA~20mA
KM2
7. Overall and mounting dimensions (mm)
L1 L2 L3 N
QF
KM1
M
3~
SB2 SB1 KM1
KM1
CT
1 23456 7
A1 A2 07 08 98 95 96
10 C1
11 C2 T1
12
T2
13
PE
8 9 14
4mA~20mA
过载 断相 不平衡 旋转
复位
80A~800A
设置
NJBK7电动机保护继电器
96.5max
113max
130.5max
152±0.5
175max
Figure 3 Autotransformer reduced voltage starting connection
diagram in case the control supply voltage is 220V and the rated
operational voltage is 220V
L1 L2 L3 N
QF
SB2
KM1 KM3
SB1 KM2 KA
KM2
KA KM1 KM2
KM2 KM3
KA KA
CT
KM2 1 2 3 4 5 6 7
A1 A2 07 08 98 95 96
10 C1 NJBK7 Motor protection delay
11 C2 T1 T2
12 13
PE
8 9 14
M 4mA~20mA
3~
I-21
> >>










Скачать PDF:

[ NJBK7.PDF Даташит ]

Номер в каталогеОписаниеПроизводители
NJBK2Motor Protection RelayCHiNT
CHiNT
NJBK5Motor ControllerCHiNT
CHiNT
NJBK5-5Motor ControllerCHiNT
CHiNT
NJBK6Motor Protection RelayCHiNT
CHiNT

Номер в каталоге Описание Производители
TL431

100 мА, регулируемый прецизионный шунтирующий регулятор

Unisonic Technologies
Unisonic Technologies
IRF840

8 А, 500 В, N-канальный МОП-транзистор

Vishay
Vishay
LM317

Линейный стабилизатор напряжения, 1,5 А

STMicroelectronics
STMicroelectronics

DataSheet26.com    |    2020    |

  Контакты    |    Поиск