OKR-T/6 Series
Adjustable Output 6-Amp SIP-mount DC/DC Converters
Typical unit
FEATURES
600 KHz operation
4.5-14 Vdc input voltage range
Programmable output voltage from 0.591-6.0 VDC
Drives up to 200 μF ceramic capacitive loads
High power conversion efficiency at 93%
Outstanding thermal derating performance
Over temperature and over current protection
On/Off control
SIP, 0.41 x 0.65 x 0.30 inches (10.4 x 16.5 x
7.62 mm).
Meets UL/EN/IEC 60950-1 safety certification
RoHS-6 hazardous substance compliance
PRODUCT OVERVIEW
The OKR-T/6 series are miniature SIP non-isolated Point-of-Load (PoL) DC/DC power converters
measuring only 0.41 x 0.65 x 0.30 inches (10.4 x 16.5 x 7.62 mm). The wide input range is 4.5 to 14
Volts DC. Based on 600 KHz synchronous buck topology, the high power conversion efficient Point of Load
(PoL) module features programmable output voltage and On/Off control, under voltage lock out (UVLO),
overcurrent and over temperature protections. These units meet all standard UL/EN/ IEC 60950-1 safety
certifications and RoHS-6 hazardous substance compliance.
+Vin
F1
On/Off
Control
External
DC
Power
Source
Open = On
Closed = Off
(Positive
On/Off)
Common
Figure 1. Connection Diagram
Controller
t4XJUDIJOH
t'JMUFST
t$VSSFOU4FOTF
Reference and
Error Amplifier
+Vout
Trim
Common
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
MDC_OKR-T/6-W12 Series.B04 Page 1 of 11







No Preview Available !

OKR-T-6-W12-C Даташит, Описание, Даташиты
OKR-T/6 Series
Adjustable Output 6-Amp SIP-mount DC/DC Converters
Performance Specifications Summary and Ordering Guide
ORDERING GUIDE
Output
Input
Root Model
IOUT R/N (mVp-p) Regulation (Max.)
IIN, IIN,
VOUT (Amps Power
VIN Nom. Range no load full load
(Volts) max) (Watts) Max.
Line Load (Volts) (Volts) (mA) (Amps)
Efficiency
Min. Typ.
OKR-T/6-W12-C 0.591-6 6
30
30
±0.3% ±0.5% 12 4.5-14 80
2.69 91.5% 93%
Package
Case Pinout
C90 P73
For Vout ≥ 3.3V, Vin should be ≥ (Vout ÷ 0.85) + 0.5V.
Ripple and Noise is shown at Vout=1V. See specs for details.
All specifications are at nominal line voltage, Vout= 5V and full load, +25 deg.C. unless
otherwise noted. Output capacitors are 1 μF ceramic and| 10 μF electrolytic in parallel.
Input cap is 22 μF. See detailed specifications. I/O caps are necessary for our test equip-
ment and may not be needed for your application.
Vin must be 2V or higher than Vout for 3.3 to 5V outputs.
PART NUMBER STRUCTURE
OK R - T / 6 - W12 - E - C
Okami Non-isolated PoL
SIP-Mount
Output Voltage Range
T = Trimmable, 0.591-6 Volts
Maximum Rated Output
Current in Amps
RoHS Hazardous
Substance Compliance
C = RoHS-6 (does not claim EU RoHS exemption 7b–lead in solder)
Forced On/Off Control
Blank = Standard on/off, open pin = ON
E = Forced enable, open pin = OFF, see specs
Wide Input Voltage Range
W12 = 4.5 – 14 Volts
Note: Some model number combinations
may not be available. Contact Murata
Power Solutions for availability.
Product Label
Because of the small size of these products, the product label contains a
character-reduced code to indicate the model number and manufacturing date
code. Not all items on the label are always used. Please note that the label dif-
fers from the product photograph on page 1. Here is the layout of the label:
Mfg.
XXXXXX
Product code
date YMDX Rev. Revision level
code
Figure 2. Label Artwork Layout
The label contains three rows of information:
First row – Murata Power Solutions logo
Second row – Model number product code (see table)
Third row – Manufacturing date code and revision level
Model Number
OKR-T/6-W12-C
OKR-T/6-W12E-C
Product Code
R01106
R01106E
The manufacturing date code is four characters:
First character – Last digit of manufacturing year, example 2009
Second character – Month code (1 through 9 = Jan-Sep;
O, N, D = Oct, Nov, Dec)
Third character – Day code (1 through 9 = 1 to 9, 10 = 0 and
11 through 31 = A through Z)
Fourth character – Manufacturing information
www.murata-ps.com/support
MDC_OKR-T/6-W12 Series.B04 Page 2 of 11







No Preview Available !

OKR-T-6-W12-C Даташит, Описание, Даташиты
Performance/Functional Specifications
All specifications are typical unless noted See Note 1.
Input
Input Voltage Range
See Ordering Guide. See note 16.
Recommended External Fuse
10 Amps
Reverse Polarity Protection (Note 9) None. Use an external fuse.
Isolation
Not isolated. The input and output
commons are internally connected.
Start-Up Voltage
4.2 Volts
Undervoltage Shutdown
3.4 Volts
Reflected (Back) Ripple Current (Note 2) 20 mA pk-pk
Internal Input Filter Type
Capacitive
Input Current:
Full Load Conditions
See Ordering Guide
Inrush Transient
0.4 A2Sec.
Shutdown Mode (Off, UV, OT)
5 mA
Output Short Circuit
60 mA
No Load, 5V out
80 mA
Low Line (Vin=Vmin, 5Vout)
4.49 Amps
Remote On/Off Control (Note 5)
Positive Logic
Current
[Standard version]
ON = +1.5 V. to +Vin max. or open pin
OFF = –0.3 to +0.4 V. max. or ground pin
1 mA
Remote On/Off Control
Positive Logic
Current
[“E” version]
ON = +2 V. to +Vin max.,
49KΩ pulldown to ground
OFF = open pin or –0.3 to +0.4 V. max.
1 mA max.
Turn-on Time:
Vin on to Vout regulated
Remote On to Vout regulated
6 mSec
6 mSec
Output
Minimum Loading
No minimum load
Output Current Range
See ordering guide
Accuracy (50% load, no trim)
±2 % of Vnom
Temperature Coefficient
±0.02% per °C. of Vout range
Ripple/Noise (20 MHz bandwidth)
See Ordering Guide and note 14
Line/Load Regulation
See Ordering Guide and note 10
Efficiency
See Ordering Guide and performance
graphs
Maximum Capacitive Loading
Cap-ESR=0.001 to 0.015 Ohms
Cap-ESR >0.015 Ohms
200 μF
1000 μF (Min. cap. = 0μF)
Current Limit Inception
(98% of Vout setting, after warm up)
9.8 Amps
Short Circuit Mode (Notes 6, 12)
Short Circuit Current Output
Protection Method
removal. (Note 8)
Short Circuit Duration
(output shorted to ground)
0.6 Amp
Hiccup autorecovery upon overload
Continuous, no damage
Overvoltage protection
None
OKR-T/6 Series
Adjustable Output 6-Amp SIP-mount DC/DC Converters
Dynamic Characteristics
Dynamic Load Response (50 to 100% load step, no external caps)
di/dt = 1 A/μSec
40 μSec to within ±2% of final value
Peak deviation
300mV
Switching Frequency
600 KHz
Environmental
Calculated MTBF (Note 4)
A: 10,347,400 hours
B: 6,559,518 hours
Operating Temperature Range
(Ambient temp., Vout=5 V., vertical mount)
Full power, see derating curves
-40 to +85 °C. with derating
Operating PC Board Range, no derating -40 to +100 °C.
Storage Temperature Range
-55 to +125 °C.
Thermal Protection/Shutdown
+130 °C.
Relative Humidity
Restriction of Hazardous Substances
to 85%/+85 °C.
RoHS-6 (does not claim EU RoHS exemption
7b–lead in solder)
Outline Dimensions
Weight
Safety
Physical
See Mechanical Specifications
0.07 ounces (2 grams)
Meets UL/cUL 60950-1
CSA-C22.2 No. 60950-1
IEC/EN 60950-1
Absolute Maximum Ratings
Input Voltage
Continuous or transient
15 Volts max.
Output Power
30 Watts max.
On/Off Control
0 Volts. min. to +Vin. max.
Input Reverse Polarity Protection
See Fuse section
Output Current
Current-limited. Devices can withstand
sustained short circuit without damage.
Storage Temperature
-40 to +125 deg. C.
Absolute maximums are stress ratings. Exposure of devices to greater than any of these
conditions may adversely affect long-term reliability. Proper operation under conditions
other than those listed in the Performance/Functional Specifications Table is not implied or
recommended.
CAUTION: This product is not internally fused. To comply with safety agency certifications
and to avoid injury to personnel or equipment, the user must supply an external fast-blow
fuse to the input terminals.
www.murata-ps.com/support
MDC_OKR-T/6-W12 Series.B04 Page 3 of 11










Всего страниц 11 Pages
Скачать PDF[ OKR-T-6-W12-C.PDF Даташит ]

Ссылка Поделиться


Related Datasheets

Номер в каталогеОписаниеПроизводители
OKR-T-6-W12-CAdjustable Output 6-Amp SIP-mount DC/DC ConvertersMurata
Murata

Номер в каталоге Описание Производители
6MBP200RA-060

Intelligent Power Module

Fuji Electric
Fuji Electric
ADF41020

18 GHz Microwave PLL Synthesizer

Analog Devices
Analog Devices
AN-SY6280

Low Loss Power Distribution Switch

Silergy
Silergy

DataSheet26.com    |    2018    |   Контакты    |    Поиск