17 Pages
scroll

No Preview Available !

OKL2-T-3-W12N-C Даташит, Описание, Даташиты
www.murata-ps.com
OKL-T/3-W12 Series
Programmable Output 3-Amp iLGA SMT PoLs
Typical unit
FEATURES
iLGA inspectable Land Grid Array
4.5-14Vdc input voltage range
Programmable output voltage from 0.591-5.5Vdc
Drives up to 200 μF ceramic capacitive loads
High power conversion efficiency at 93%
Outstanding thermal derating performance
Short circuit and over current protection
On/Off control and Power Good signal
Optional Sequence/Tracking operation
(OKL2-T/3-W12 models)
Certified to UL/EN/IEC 60950-1 safety, 2nd Edition
RoHS-6 hazardous substance compliance
PRODUCT OVERVIEW
The OKL-T/3-W12 series are miniature
non-isolated Point-of-Load (PoL) DC/DC power
converters for embedded applications. Featuring
inspectable Land Grid Array (iLGA) format, the
OKL-T/3-W12 measures only 0.48 x 0.48 x 0.244
inches max. (12.2 x 12.2 x 6.2 mm max.).
The wide input range is 4.5 to 14 Volts DC.
The maximum output current is 3 Amps. Based
on fixed-frequency synchronous buck converter
switching topology, the high power conversion
efficient Point of Load (PoL) module features
programmable output voltage and On/Off control.
These converters also include under voltage lock
out (UVLO), output short circuit protection, and
over-current protections.
An optional sequence/tracking feature on
OKL2-T/3-W12 models allows power sequencing of
PoL’s. These units are certified to all standard UL/EN/
IEC 60950-1 safety certifications (2nd Edition) and
RoHS-6 hazardous substance compliance.
Connection Diagram
+Vin
F1
On/Off
Control
External
DC
Power
Source
Open = On
Closed = Off
(Positive
On/Off)
Controller
t4XJUDIJOH
t'JMUFST
t$VSSFOU4FOTF
Reference and
Error Amplifier
Common
Sequence/Tracking
(OKL2 Models)
Power Good
Figure 1. OKL-T/3-W12
Note: Murata Power Solutions strongly recommends an external input fuse, F1.
See specifications.
+Vout
Sense
Trim
Common
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
MDC_OKL-T/3-W12 Series.C01 Page 1 of 17









No Preview Available !

OKL2-T-3-W12N-C Даташит, Описание, Даташиты
OKL-T/3-W12 Series
Programmable Output 3-Amp iLGA SMT PoLs
Performance Specifications and Ordering Guide
ORDERING GUIDE
Model Number
Output
Input Package - Pinout P83
Vout
Iout (Amps, Power
R/N (mV p-p) Regulation (max.) Vin nom. Range Iin, no load Iin, full load
Efficiency
On/Off Seq/
Logic Track
Case C83
(Volts) max.) (Watts) Max. Line Load (Volts) (Volts) (mA) (Amps) Min. Typ.
inches (mm)
OKL-T/3-W12P-C 0.591-5.5 3 15.0 37 ±0.25% ±0.25% 12 4.5-14 20
1.34
91% 93% Pos.
no
0.48x0.48x0.244 max
12.2x12.2x6.2 max
OKL-T/3-W12P-C/S 0.591-5.5 3 15.0 37 ±0.25% ±0.25% 12 4.5-14 20
1.34
91% 93% Pos.
no
0.48x0.48x0.244 max
12.2x12.2x6.2 max
OKL-T/3-W12N-C 0.591-5.5 3 15.0 37 ±0.25% ±0.25% 12 4.5-14 20
1.34
91% 93% Neg.
no
0.48x0.48x0.244 max
12.2x12.2x6.2 max
OKL-T/3-W12N-C/S 0.591-5.5 3 15.0 37 ±0.25% ±0.25% 12 4.5-14 20
1.34
91% 93% Neg.
no
0.48x0.48x0.244 max
12.2x12.2x6.2 max
OKL2-T/3-W12P-C 0.591-5.5 3 15.0 37 ±0.25% ±0.25% 12 4.5-14 20
1.34
91% 93% Pos.
yes
0.48x0.48x0.244 max
12.2x12.2x6.2 max
OKL2-T/3-W12N-C 0.591-5.5 3 15.0 37 ±0.25% ±0.25% 12 4.5-14 20
1.34
91% 93% Neg.
yes
0.48x0.48x0.244 max
12.2x12.2x6.2 max
The output range is limited by Vin. See detailed specs.
All specifications are at nominal line voltage, Vout=nominal (5V for W12 models) and full load,
+25 deg.C. unless otherwise noted.
Output capacitors are 10 μF ceramic. Input cap is 22 μF. See detailed specifications.
I/O caps are necessary for our test equipment and may not be needed for your application.
Use adequate ground plane and copper thickness adjacent to the converter.
Ripple and Noise (R/N) and no-load input current are shown at Vout=1V. See specs for details.
PART NUMBER STRUCTURE
OK L 2 - T / 3 - W12 N - C / S
Non-isolated PoL
LGA Surface Mount
Sequence/tracking
Blank = Not installed
2 = Installed
Trimmable Output
Voltage Range
0.591-5.5Vdc
Maximum Rated Output
Current in Amps
Packaging
Blank = standard (400 units per reel)
S = small (100 units per reel)
RoHS Hazardous
Substance Compliance
C = RoHS-6 (does not claim EU RoHS exemption
7b–lead in solder)
On/Off Logic
P = Positive Logic
N = Negative Logic
Input Voltage Range
4.5-14Vdc
Product Label
Because of the small size of these products, the product label contains a
character-reduced code to indicate the model number and manufacturing date
code. Not all items on the label are always used. Please note that the label
differs from the product photograph. Here is the layout of the label:
The label contains three rows of information:
Model Number
OKL-T/3-W12P-C
OKL-T/3-W12P-C/S
OKL-T/3-W12N-C
OKL-T/3-W12N-C/S
OKL2-T/3-W12P-C
OKL2-T/3-W12N-C
Product Code
L01103
L00103
L21103
L20103
Mfg.
XXXXXX
Product code
date YMDX Rev. Revision level
code
Figure 2. Label Artwork Layout
First row – Murata Power Solutions logo
Second row – Model number product code (see table)
Third row – Manufacturing date code and revision level
www.murata-ps.com/support
The manufacturing date code is four characters:
First character – Last digit of manufacturing year, example 2009
Second character – Month code (1 through 9 = Jan-Sep;
O, N, D = Oct, Nov, Dec)
Third character – Day code (1 through 9 = 1 to 9, 10 = 0 and
11 through 31 = A through Z)
Fourth character – Manufacturing information
MDC_OKL-T/3-W12 Series.C01 Page 2 of 17









No Preview Available !

OKL2-T-3-W12N-C Даташит, Описание, Даташиты
Performance and Functional Specifications
See Note 1
Input
Input Voltage Range
See Ordering Guide and Note 7.
Isolation
Not isolated
Start-Up Voltage
4.2 V
Undervoltage Shutdown (see Note 15) 3.4 V
Overvoltage Shutdown
None
Reflected (Back) Ripple Current (Note 2) 49 mA pk-pk
Internal Input Filter Type
Capacitive
Recommended External Fuse
4A
Reverse Polarity Protection
None, install external fuse
Input Current:
Full Load Conditions
Inrush Transient
Shutdown Mode (Off, UV, OT)
Output in Short Circuit
Low Line (Vin=Vmin)
See Ordering Guide
0.16 A2Sec.
1 mA
5 mA
2.24 A.
Remote On/Off Control (Note 5)
Negative Logic
Positive Logic
Current
ON = Open pin or -0.2V to +0.3V. max.
OFF = +3.5V min. to +Vin max.
ON = Open pin (internally pulled up) or
+3.5V to +Vin max.
OFF = -0.3V to +0.4V. max. or ground
1 mA max.
Tracking/Sequencing (optional)
Slew Rate
Tracking accuracy, rising input
Tracking accuracy, falling input
See technical note on page 16
2 Volts per millisecond, max.
Vout = ±100 mV of Sequence In
Vout = ±100 mV of Sequence In
Output
Output Power
16.5W max.
Output Voltage Range
See Ordering Guide
Minimum Loading
No minimum load
Accuracy (50% load, untrimmed)
±1.5 % of Vnominal
Voltage Output Range (Note 13)
See Ordering Guide
Overvoltage Protection (Note 16)
None
Temperature Coefficient
±0.02% per °C of Vout range
Ripple/Noise (20 MHz bandwidth)
See Ordering Guide and note 8
Line/Load Regulation
See Ordering Guide and note 10
Efficiency
See Ordering Guide
Maximum Capacitive Loading (Note 14)
Cap-ESR=0.001 to 0.01 Ohms
200 μF
Cap-ESR >0.01 Ohms
TBD
Current Limit Inception (Note 6)
(98% of Vout setting, after warm up) 6 Amps
Short Circuit Mode
Short Circuit Current Output
Protection Method
Short Circuit Duration
Prebias Startup
10 mA
Hiccup autorecovery upon overload
removal. (Note 17)
Continuous, no damage
(output shorted to ground)
Converter will start up if the external
output voltage is less than Vnominal.
Power Good output
PGood TRUE (HI)
PGood FALSE (LO)
External pullup voltage
open drain configuration, 5 mA sink max.
(Vset -10%) < Vout < (Vset +10%)
0.0V < Vout < 0.4V. See App. note.
+5V max., referred to -Vin
www.murata-ps.com/support
OKL-T/3-W12 Series
Programmable Output 3-Amp iLGA SMT PoLs
Dynamic Characteristics
Dynamic Load Response
200μSec max. to within ±2% of final value
(50-100% load step, di/dt=1A/µSec) (Note 1)
Peak Deviation
250 mV
Start-Up Time
6 mSec for Vout=nominal (Vin On)
(Vin on or On/Off to Vout regulated) 6 mSec for Vout=nominal (Remote On/Off)
Switching Frequency
600 KHz
Environmental
Calculated MTBF (hours)
Telecordia method (4a)
Calculated MTBF (hours)
MIL-HDBK-217N2 method (4b)
OKL-T/3-W12 OKL2-T/3-W12
10,011,000
9,227,000
4,448,000
4,392,000
Operating Temperature Range (Ambient, vertical mount)
See derating curves
-40 to +85 °C. with derating (Note 9)
Storage Temperature Range
-55 to +125 °C.
Thermal Protection/Shutdown
Included in PWM
MSL Rating
2
Relative Humidity
to 85%/+85 °C., non-condensing
Physical
Outline Dimensions
See Mechanical Specifications
Weight
0.06 ounces (1.6 grams)
Plating Thickness
Gold overplate 1.18μ" (0.03μm)
on Nickel subplate 118.1μ" (3.0μm)
Safety
Certified to UL/cUL 60950-1, CSA-
C22.2 No. 60950-1, IEC/EN 60950-1,
2nd Edition
Restriction of Hazardous Substances
RoHS-6 (does not claim EU RoHS exemption
7b–lead in solder)
Absolute Maximum Ratings
Input Voltage (Continuous or transient) 0 V. to +15 Volts max.
On/Off Control
0 V. min. to +Vin max.
Input Reverse Polarity Protection
None, install external fuse
Output Current (Note 7)
Current-limited. Devices can withstand a
sustained short circuit without damage.
The outputs are not intended to accept
appreciable reverse current.
Storage Temperature
-55 to +125 ˚C.
Lead Temperature
See soldering specifications
Absolute maximums are stress ratings. Exposure of devices to greater than any of
any of these conditions may adversely affect long-term reliability. Proper operation
under conditions other than those listed in the Performance/Functional Specifications
Table is not implied or recommended.
Specification Notes:
(1) Specifications are typical at +25 °C, Vin=nominal (+12V.), Vout=nominal (+5V), full load, external caps and
natural convection unless otherwise indicated. Extended tests at full power must supply substantial forced
airflow.
All models are tested and specified with external 10μF ceramic output capacitors and a 22 μF external
input capacitor. All capacitors are low ESR types. These capacitors are necessary to accommodate our test
equipment and may not be required to achieve specified performance in your applications. However, Murata
Power Solutions recommends installation of these capacitors. All models are stable and regulate within
spec under no-load conditions.
(2) Input Back Ripple Current is tested and specified over a 5 Hz to 20 MHz bandwidth. Input filtering is Cin=2 x
100 μF ceramic, Cbus=1000 μF electrolytic, Lbus=1 μH.
(3) Note that Maximum Power Derating curves indicate an average current at nominal input voltage. At higher
temperatures and/or lower airflow, the DC/DC converter will tolerate brief full current outputs if the total
RMS current over time does not exceed the Derating curve.
MDC_OKL-T/3-W12 Series.C01 Page 3 of 17










Скачать PDF:

[ OKL2-T-3-W12N-C.PDF Даташит ]

Номер в каталогеОписаниеПроизводители
OKL2-T-3-W12N-CProgrammable Output 3-Amp iLGA SMT PoLsMurata
Murata

Номер в каталоге Описание Производители
TL431

100 мА, регулируемый прецизионный шунтирующий регулятор

Unisonic Technologies
Unisonic Technologies
IRF840

8 А, 500 В, N-канальный МОП-транзистор

Vishay
Vishay
LM317

Линейный стабилизатор напряжения, 1,5 А

STMicroelectronics
STMicroelectronics

DataSheet26.com    |    2020    |

  Контакты    |    Поиск