FEATURES
n UL 60950 recognized
n RoHS compliant
n 4:1 Wide range voltage input
n Operating temperature range –40°C to
85°C
n Typical load regulation from 0.06%
n 1.5kVDC Isolation
n Typical efficiency to 87%
n 12V & 48V Nominal input
n Power density 0.94W/cm3
n UL 94V-0 Package materials
n No electrolytic capacitors
n Low noise
n Under voltage lock out
n Current fold back
PRODUCT OVERVIEW
The NCS6 series of DC/DC converters offers
single & dual output voltages from input voltage
ranges of 9-36V and 18-75V. The NCS6 is housed
in an industry standard package with a standard
pinout. The NCS6 is packaged in a metal case for
improved EMI shielding and is also encapsulated
for superior thermal performance.
Applications include telecommunications, battery
powered systems, process control and distributed
power systems.
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
NCS6 Series
Isolated 6W 4:1 Input Single & Dual Output DC/DC Converters
SELECTION GUIDE
Input
Voltage
Order Code
Nom.
NCS6D1205C
NCS6D1212C
NCS6D1215C
NCS6S1203C
NCS6S1205C
NCS6S1212C
NCS6S1215C
NCS6D4805C
NCS6D4812C
NCS6D4815C
NCS6S4803C
NCS6S4805C
NCS6S4812C
NCS6S4815C
V
12
12
12
12
12
12
12
48
48
48
48
48
48
48
Output
Voltage
V
±5
±12
±15
3.3
5
12
15
±5
±12
±15
3.3
5
12
15
Output
Current 
100%
Load
A
±0.6
±0.25
±0.2
1.52
1.2
0.5
0.4
±0.6
±0.25
±0.2
1.52
1.2
0.5
0.4
Input Current
0% 100%
Load Load
mA mA
7 610
10 580
12 580
10 550
7 610
10 580
12 580
6 160
7 150
7 150
10 150
6 160
7 150
7 150
Ripple &
Noise
(Typ.)
mV p-p
15
10
20
30
30
30
30
50
30
30
40
30
30
30
Efficiency
Min. Typ.
%%
80 82
82 86
84 87
75 78
79 82
84 86
85 87
79 80
82 84
82 84
73 76
78 80
82 84
83 84
MTTF1
Hrs
384,470
406,121
344,957
662,073
521,975
435,567
437,582
373,195
391,563
330,752
483,460
441,850
408,555
416,319
INPUT CHARACTERISTICS
Parameter
Conditions
Voltage range
12V input types
48V input types
Turn on threshold 12V input types
Under voltage lock out
Turn off threshold 12V input types
Turn on threshold 48V input types
Turn off threshold 48V input types
Reflected ripple current
12V input types
48V input types
Single output types
Dual output types
Single output types
Dual output types
Min. Typ. Max. Units
9 12 36
18 48 75
V
8.5
7.5
16.7
V
15.8
12
4
9
6
mA p-p
OUTPUT CHARACTERISTICS
Parameter
Conditions
Rated power
5V, 12V & 15V output types
3.3V output types
Voltage set point accuracy
Positive outputs
Negative outputs
Line regulation
Low line to high line
Positive outputs
Negative outputs
3V outputs
Load Regulation
10% total load to
100% total load
5V positive outputs
12V & 15V positive outputs
Cross Regulation
% voltage change on
negative output when
positive load varies
from 12.5% to 37.5%
with negative load fixed
at 50%
3.3V & 5V output
types
All negative outputs
5V
12V & 15V
Single output types
Dual output types
Start-up Time
12V output types
Single output types
Dual output types
15V output types
Single output types
Dual output types
Min.
Typ.
0.002
0.09
0.5
0.3
0.06
0.2
2.5
25
4.6
11
5.5
14
1 Calculated using MIL-HDBK-217F FN2, parts stress method with nominal input voltage at full load.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
Max.
6
5
±2
±3
0.2
0.7
0.6
0.5
0.2
1.0
5
2.5
Units
W
%
%
%
%
mS
KDC_NCS6C.D04  Page 1 of 10









No Preview Available !

NCS6S4815C Даташит, Описание, Даташиты
NCS6 Series
Isolated 6W 4:1 Input Single & Dual Output DC/DC Converters
ISOLATION CHARACTERISTICS
Parameter
Isolation test voltage
Resistance
Capacitance
Conditions
Flash tested for 1 seconds
Viso = 1kVDC
Min. Typ. Max.
1500
1
225
ABSOLUTE MAXIMUM RATINGS
Short-circuit protection (for SELV input voltages)
Internal power dissipation
Lead temperature 1.0mm from case for 10 seconds
(to JEDEC JESD22-B106 ISS C)
Minimum output load for specification (see application notes)
Input voltage, NCS6 12V input types
Input voltage, NCS6 48V input types
GENERAL CHARACTERISTICS1
Parameter
Switching frequency
Conditions
Continuous
2.1W
260°C
10% of rated load
40V
80V
Min. Typ. Max.
180
TEMPERATURE CHARACTERISTICS
Parameter
Operation
Storage
Case temperature rise above ambient
Thermal shutdown
Conditions
100% Load, Nom VIN,
Still Air
Case Temperature
48VIN Dual outputs
All other output types
5V
12V
15V
3.3V
5V
12V
15V
Min. Typ. Max.
-40 85
-50 125
36
32
31
32
32
28
26
105
APPLICATION NOTES
Output Capacitors
The NCS6 series does not require output capacitors to meet datasheet specification. To meet datasheet specification, total output capacitance should not exceed:
Output Voltage (V)
3.3
5
12
15
Output Capacitance (µF)
470
470
220
220
Units
VDC
GΩ
pF
Units
kHz
Units
°C
Minimum Load
The minimum load to meet full datasheet specification is 10% of the full rated load across the specified input voltage range.
Between 0% and 10% output loading, the positive output voltage will remain within data sheet specification however, output ripple and noise will increase as well as a
decrease in accuracy on negative outputs.
www.murata-ps.com/support
KDC_NCS6C.D04  Page 2 of 10









No Preview Available !

NCS6S4815C Даташит, Описание, Даташиты
NCS6 Series
Isolated 6W 4:1 Input Single & Dual Output DC/DC Converters
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions NCS6 series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1.5kVDC for 1 second.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
The NCS6 has been recognized by Underwriters Laboratory for functional isolation. Both input and output should normally be maintained within SELV limits i.e. less than 42.4V
peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system.
The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier
must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according
to safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,
construction and environment. The NCS6 series has an ER ferrite core, with no additional insulation between primary and secondary windings of enameled wire. While parts can be
expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically polyurethane)
is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly
advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage.
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
SAFETY APPROVAL
The NCS6 series has been recognised by Underwriters Laboratory (UL) to UL 60950 for functional insulation in a maximum ambient temperature of 85ºC and/or case temperature
limit of 120ºC (case temperature measured on the face opposite the pins). File number E151252 applies.
Note: This series gained UL 60950 recognition for products manufactured on or after datecode G1114, any NCS6 parts manufactured before this date code should not be considered
UL 60950 recognized. Any NCS6 that is UL recognized will be printed with the UL logo.
RoHS COMPLIANCE INFORMATION
This series is compatible with RoHS soldering systems with a peak wave solder temperature of 260ºC for 10 seconds. The pin termination finish
on this product series is a Gold flash (0.05-0.10 micron) over Nickel Preplate. The series is backward compatible with Sn/Pb soldering systems.
For further information, please visit www.murata-ps.com/rohs
CHARACTERISATION TEST METHODS
Ripple & Noise Characterisation Method
Ripple and noise measurements are performed with the following test configuration.
C1 1µF X7R multilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC/DC converter
C2
10µF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC/DC converter with an ESR of less
than 100mΩ at 100 kHz
C3 100nF multilayer ceramic capacitor, general purpose
R1 450Ω resistor, carbon film, ±1% tolerance
R2 50Ω BNC termination
T1 3T of the coax cable through a ferrite toroid
RLOAD
Resistive load to the maximum power rating of the DC/DC converter. Connections should be made via twisted wires
Measured values are multiplied by 10 to obtain the specified values.
Differential Mode Noise Test Schematic
SUPPLY
DC/DC Converter
++
Input Output
--
C1 C2 C3 R1
OSCILLOSCOPE
T1 R2
Y INPUT
www.murata-ps.com/support
R LOAD
KDC_NCS6C.D04  Page 3 of 10










Скачать PDF:

[ NCS6S4815C.PDF Даташит ]

Номер в каталогеОписаниеПроизводители
NCS6S4815CIsolated 6W 4:1 Input Single & Dual Output DC/DC ConvertersMurata
Murata

Номер в каталоге Описание Производители
TL431

100 мА, регулируемый прецизионный шунтирующий регулятор

Unisonic Technologies
Unisonic Technologies
IRF840

8 А, 500 В, N-канальный МОП-транзистор

Vishay
Vishay
LM317

Линейный стабилизатор напряжения, 1,5 А

STMicroelectronics
STMicroelectronics

DataSheet26.com    |    2020    |

  Контакты    |    Поиск