DataSheet26.com

H7BX PDF даташит

Спецификация H7BX изготовлена ​​​​«Omron» и имеет функцию, называемую «Multifunction Counter».

Детали детали

Номер произв H7BX
Описание Multifunction Counter
Производители Omron
логотип Omron логотип 

27 Pages
scroll

No Preview Available !

H7BX Даташит, Описание, Даташиты
Multifunction Counter (DIN 72 × 72)
H7BX
CSM_H7BX_DS_E_4_4
DIN 72 × 72 mm Multifunction Counter with a
Bright, Easy-to-view, Negative Transmissive LCD.
• Highly visible display with backlit transmissive LCD.
• Selectable display color (red/green) enables checking output status at a
distance.
• Easy operation with a key for each digit.
• Perform all basic settings with a DIP switch.
• Provides a total and preset counter, batch counter, dual counter, and
tachometer (See note.).
• Wide range of inputs accepted for NPN/PNP inputs (multi-inputs) and 2-
wire DC sensors.
• Complies with UL, CSA, and CE marking.
• Degree of protection: IP54 equivalent (front section only).
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Note: The functions that can be selected depend on the model.
Refer to Safety Precautions on page 25.
Ordering Information
List of Models
External power supply
Output type
12 VDC
Contact and
NPN transistor output
Accessories (Order Separately)
Name
Soft Cover
Hard Cover
Terminal Cover *
Model
Y92A-72F1
Y92A-72
Y92A-72T
* Supplied with the H7BX.
Supply voltage
100 to 240 VAC
24 VAC/12 to 24 VDC
1-stage
H7BX-A
H7BX-AD1
2-stage
H7BX-AW
H7BX-AWD1
1









No Preview Available !

H7BX Даташит, Описание, Даташиты
H7BX
Specifications
Ratings
Item
Model
H7BX-A/AD1
H7BX-AW/AWD1
Type
Preset counter
Preset counter/tachometer
Supported configurations
1-stage preset counter, total and preset counter *1
(selectable)
1-stage preset counter, 2-stage preset counter, total and
preset counter (*1), batch counter, dual counter, tachometer
(selectable)
Power supply voltage *2
100 to 240 VAC (50/60 Hz)
24 VAC (50/60 Hz)/12 to 24 VDC (ripple 20% max.)
Ratings Operating voltage range 85% to 110% of rated supply voltage (90% to 110% at 12 VDC)
Power consumption
H7BX-A/AW: 9.6 VA max. (100 to 240 VAC)
H7BX-AD1/AWD1: 8 VA max. (24 VAC), 5.3 W max. (12 to 24 VDC)
Mounting method
Flush mounting
External connections
Screw terminals
Degree of protection
IP54 (front section only)
Input signals
CP1, CP2, reset 1, reset 2, key protection
Max. counting speed 30 Hz or 5 kHz (selectable, ON/OFF ratio 1:1), setting for both CP1 and CP2
Input modes
Increment, decrement, command (UP/DOWN A), individual (UP/DOWN B), quadrature (UP/DOWN C)
Counter Output modes
One-shot output time
N, F, C, R, K-1, P, Q, A, K-2, D, L
0.01 to 99.99 s
N, F, C, R, K-1, P, Q, A, K-2, D, L, H
Reset input
External reset (minimum reset input signal width: 1 ms or 20 ms selectable), manual reset, and automatic reset (internal
according to C, R, P, and Q mode operation)
Pulse measurement
method
--- Periodic measurement (Sampling period: 200 ms)
Max. counting speed
--- 30 Hz or 10 kHz (selectable)
Measuring ranges
Tachometer Measuring accuracy
---
30 Hz: 0.01 to 30.00 Hz
10 kHz: 0.01 Hz to 10 kHz
--- ±0.1% FS ±1 digit max. (at 23 ±5°C)
Output modes
--- Upper and lower limits, area, upper limit, lower limit
Auto-zero time
--- 0.1 to 99.9 s
Startup time
--- 0.0 to 99.9 s
Average processing
--- OFF/2/4/8 times
Prescaling function
Yes (0.001 to 99.999)
Decimal point adjustment
Yes (rightmost 3 digits)
Sensor waiting time
290 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.)
Key protection input
Response speed: Approx. 1 s
No-voltage NPN input (fixed)
Short-circuit (ON) impedance: 1 kΩ max. (Leakage current at 0 Ω: Approx. 12 mA)
Short-circuit (ON) residual voltage: 3 V max.
Open (OFF) impedance: 100 kΩ min.
Input method
(except key protection input)
No-voltage NPN input or voltage PNP input (selectable)
No-voltage input
Short-circuit (ON) impedance: 1 kΩ max. (Leakage current at 0 Ω: Approx. 12 mA)
Short-circuit (ON) residual voltage: 3 V max.
Open (OFF) impedance: 100 kΩ min.
Voltage input
High level: 4.5 to 30 VDC
Low level: 0 to 2 VDC
Input resistance: Approx. 4.7 kΩ
External power supply
12 VDC (±10%), 100 mA (For details, refer to External Power Supply on page 26.)
Control output
Contact output: 3 A at 250 VDC/30 VDC, resistive load (cosφ = 1)
Minimum applied load: 10 mA at 5 VDC (Failure level: P, reference value)
Transistor output: 100 mA max. at 30 VDC max.
Residual voltage: 1.5 VDC max. (approx. 1 V)
Leakage current: 0.1 mA max.
Display *3
Backlit 7-segment negative transmissive LCD
Character Heights
PV: 13.5 mm (red/green)
SV: 9 mm (green)
Digits
6 digits
99,999 to 999,999 (5 digits negative and 6 digits positive)
6 digits
Counter: 99,999 to 999,999 (5 digits negative and 6 digits
positive)
Tachometer: 0 to 999,999 (6 digits)
Memory backup
EEPROM (Overwrites: 100,000 min.), Data storage: 10 years min.
Ambient operating temperature
10 to 55°C (with no icing)
Ambient storage temperature
25 to 65°C (with no icing)
Ambient operating humidity
25 to 85°C (with no condensation)
Case color
Black (N1.5)
Accessories
Two flush-mounting adapters, terminal cover
Two flush-mounting adapters, terminal cover, DIP switch
setting stickers
*1. The total and preset counter functions as a 1-stage preset counter and total counter.
*2. Do not use an inverter output for the power supply.
*3. Displayed only when the power is ON. Not displayed when the power is OFF.
2









No Preview Available !

H7BX Даташит, Описание, Даташиты
H7BX
Characteristics
Insulation
resistance
Dielectric
strength
Impulse
withstand
voltage
Noise
immunity
Static
immunity
Vibration
resistance
Shock
resistance
Life
expectancy
Weight
100 MΩ min. (at 500 VDC) between current-carrying terminal and exposed
non-current-carrying metal parts, and between non-continuous contacts
Between current-carrying metal parts and non-current-carrying metal parts:
2,000 VAC, 50/60 Hz for 1 min
Between power supply and input circuit: 2,000 VAC, 50/60 Hz for 1 min
(for models other than the H7BX-A@D1)
1,000 VAC, 50/60 Hz for 1 min (H7BX-A@D1)
Between control output, power supply, and input circuit: 2,000 VAC,
50/60 Hz for 1 min
Between non-continuous contacts: 1,000 VAC, 50/60 Hz for 1 min
Between power terminals: 3.0 kV (1.0 kV for 24 VAC/12 to 24 VDC models)
Between current-carrying terminal and exposed non-current-carrying metal
parts:
4.5 kV (1.5 kV for 24 VAC/12 to 24 VDC models)
Between power terminals: ±1.5 kV
Between input terminals: ±600 V
Square-wave noise by noise simulator (Pulse width: 100 ns/1 μs, 1-ns rise)
Malfunction: 8 kV
Destruction: 15 kV
Destruction: 10 to 55 Hz, 0.75-mm single amplitude, 2 hours each in three
directions
Malfunction: 10 to 55 Hz, 0.50-mm single amplitude, 10 minutes each in
three directions
Destruction: 294 m/s2 3 times each in 6 directions
Malfunction: 98 m/s2 3 times each in 6 directions
Mechanical: 10,000,000 operations min.
Electrical: 100,000 operations min. (3 A at 250 VAC/30 VDC, resistive load) *
Approx. 250 g
* Check the electrical life expectancy curve.
Applicable Standards
Approved
safety
standards
EMC
cURus: UL 508, CSA C22.2 No. 14
EN 61010-1 (IEC 61010-1): Pollution degree 2/overvoltage category II;
EN 61326; VDE 0106 Part 100
(EMI)
EN 61326-1 *
Emission Enclosure:
EN 55011 Group 1 class A
Emission AC mains:
EN 55011 Group 1 class A
(EMS)
EN 61326-1 *
Immunity ESD:
EN 61000-4-2: 4 kV contact discharge;
8 kV air discharge
Immunity RF-interference:
EN 61000-4-3: 10 V/m (Amplitude-modulated,
80 MHz to 1 GHz);
10 V/m (Pulse-modulated,
900 MHz ±5 MHz)
Immunity Conducted Disturbance: EN 61000-4-6: 3 V (0.15 to 80 MHz)
Immunity Burst:
EN 61000-4-4: 2 kV power-line;
1 kV I/O signal-line
Immunity Surge:
EN 61000-4-5: 1 kV line to lines (power and output lines
(relay outputs));
2 kV line to ground (power and output
lines (relay outputs))
Immunity Voltage Dip/Interruption: EN 61000-4-11: 0.5 cycle, 100% (rated voltage)
* Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)
Electrical Life Expectancy
(Reference Values)
Resistive Load
1,000
700
500
300
30 VDC (cosφ=1)
100
70
50
0
250 VAC (cosφ=1)
12
Inductive Load
1,000
700
500
34
Load current (A)
300
30 VDC (L/R=7 ms)
100
250 VAC (cosφ=0.4)
70
50
01 2 34
Load current (A)
A current of 0.15 A max. can be switched at
125 VDC (cosφ = 1) and current of 0.1 A max.
can be switched with L/R = 7 m/s. In both
cases, a life of 100,000 operations can be
expected.
3










Скачать PDF:

[ H7BX.PDF Даташит ]

Номер в каталогеОписаниеПроизводители
H7BXMultifunction CounterOmron
Omron

Номер в каталоге Описание Производители
TL431

100 мА, регулируемый прецизионный шунтирующий регулятор

Unisonic Technologies
Unisonic Technologies
IRF840

8 А, 500 В, N-канальный МОП-транзистор

Vishay
Vishay
LM317

Линейный стабилизатор напряжения, 1,5 А

STMicroelectronics
STMicroelectronics

DataSheet26.com    |    2020    |

  Контакты    |    Поиск