Número de pieza | LS013B7DH05 | |
Descripción | LCD Module | |
Fabricantes | Sharp | |
Logotipo | ||
Hay una vista previa y un enlace de descarga de LS013B7DH05 (archivo pdf) en la parte inferior de esta página. Total 29 Páginas | ||
No Preview Available ! 1 page SPEC No.
LD-26912A
MODEL No.
LS013B7DH05
PAGE
3
(16) As this LCD module is composed electronic circuits, it is sensitive to electrostatic discharge of 200V or
more. Handle with care using cautions for the followings:
Operators
Operators must wear anti-static wears to prevent electrostatic charge up to and discharge from
human body.
Equipment and containers
Process equipment such as conveyer, soldering iron, working bench and containers may possibly
generate electrostatic charge up and discharge. Equipment must be grounded through 100Mohms
resistance. Use ion blower.
Floor
Floor plays an important role in leaking static electricity generated in human body or equipment. If
the floor is made of insulated material (such as polymer or rubber material), such static electricity
may charge. Proper measure should be taken to avoid static electricity charge (electrostatic earth:
100Mohms).There is a possibility that the static electricity is charged to them without leakage in case
of insulating floor, so the electrostatic earth:1×108Ω should be made.
Humidity
Humidity in work area relates to surface resistance of the persons or objects that
generate electrostatics, and it can be manipulated to prevent electrostatic charge.
Humidity of 40% or lower increases electrostatic earth resistance and promotes
electrostatic charging. Therefore, the humidity in the work area should be kept above
40%. Specifically for film peeling process or processes that require human hands,
humidity should be kept above 50% and use electricity removal blower.
Transportation/Storage
Containers and styroform used in transporation and storage may charge electrostatic (from friction
and peeling) or electrostatic charge from human body, etc. may cause containers and styroform to
have induced charge. Proper electrostatic measure should be taken for containers and storage
material.
5 Page SPEC No.
LD-26912A
MODEL No.
LS013B7DH05
PAGE
9
5. Absolute Maximum Rating
Table5-1 Absolute Maximum Rating ( VSS=0V , VSSA=0V )
Item
Symbol
MIN.
MAX.
Unit Remark
Power
Analog
VDDA
-0.3
+3.6
V
supply
voltage
Logic
VDD -0.3 +3.6
V [5-1]
Input signal voltage(high)
VDD
V [5-2]
Input signal voltage(low)
-0.3 V
Strage Temperature
Tstg -30 +80
℃ [5-3,4]
Operation Temperature
(at panel surface)
Topr1
-20
+70
℃ [5-4,5]
[5-1] Applies to EXTMODE.
[5-2] Applies to SCLK, SI, SCS, DISP, EXTCOMIN.
[5-3] Do not exceed this temperature in any parts of module.
[5-4] Maximum wet bulb temperature is 57℃ or lower. No condensation is allowed.
Cndensation will cause electeical leak and may cause the module to not meet this specification.
[5-5] Operating temperature is the temperature that guarantees only for the operation.
For contrast, response time, and other display quality determination, use Ta=+25℃.
11 Page |
Páginas | Total 29 Páginas | |
PDF Descargar | [ Datasheet LS013B7DH05.PDF ] |
Número de pieza | Descripción | Fabricantes |
LS013B7DH01 | LCD Module | Sharp |
LS013B7DH03 | Application Information for LCD Module | Sharp |
LS013B7DH03 | LCD Module | Sharp |
LS013B7DH05 | LCD Module | Sharp |
Número de pieza | Descripción | Fabricantes |
SLA6805M | High Voltage 3 phase Motor Driver IC. |
Sanken |
SDC1742 | 12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters. |
Analog Devices |
DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares, |
DataSheet.es | 2020 | Privacy Policy | Contacto | Buscar |